Tiny golden angle ultrashort echo-time lung imaging in mice.
2D UTE, fractional ventilation, lung, lung density, MRI, perfusion, self-gating, T2*, tiny golden angle
Journal
NMR in biomedicine
ISSN: 1099-1492
Titre abrégé: NMR Biomed
Pays: England
ID NLM: 8915233
Informations de publication
Date de publication:
11 2021
11 2021
Historique:
revised:
25
06
2021
received:
09
12
2020
accepted:
04
07
2021
pubmed:
30
7
2021
medline:
19
2
2022
entrez:
29
7
2021
Statut:
ppublish
Résumé
Imaging the lung parenchyma with MRI is particularly difficult in small animals due to the high respiratory and heart rates, and ultrashort T2* at high magnetic field strength caused by the high susceptibilities induced by the air-tissue interfaces. In this study, a 2D ultrashort echo-time (UTE) technique was combined with tiny golden angle (tyGA) ordering. Data were acquired continuously at 11.7 T and retrospective center-of-k-space gating was applied to reconstruct respiratory multistage images. Lung (proton) density (f
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
e4591Subventions
Organisme : Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)
ID : 465599659
Informations de copyright
© 2021 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
Références
Barrios R. Animal models of lung disease. In: Basic Concepts of Molecular Pathology. Springer; 2009.
Takahashi M, Kubo S, Kiryu S, Gee J, Hatabu H. MR microscopy of the lung in small rodents. Eur J Radiol. 2007;64:367-374.
Schuster DP, Kovacs A, Garbow J, Piwnica-Worms D. Recent advances in imaging the lungs of intact small animals. Am J Respir Cell Mol Biol. 2004;30:129-138.
Graves PR, Siddiqui F, Anscher MS, Movsas B. Radiation pulmonary toxicity: from mechanisms to management. Semin Radiat Oncol. 2010;20:201-207.
Wild JM, Marshall H, Bock M, et al. MRI of the lung (1/3): methods. Insights Imaging. 2012;3:345-353.
Bell RD, Rudmann C, Wood RW, Schwarz EM, Rahimi H. Longitudinal micro-CT as an outcome measure of interstitial lung disease in TNF-transgenic mice. PLoS ONE. 2018;13(1):e0190678.
Bergin CJ, Pauly JM, Macovski A. Lung parenchyma: projection reconstruction MR imaging. Radiology. 1991;179:777-781.
Gewalt SL, Glover GH, Hedlund LW, Cofer GP, Macfall JR, Johnson GA. MR microscopy of the rat lung using projection reconstruction. Magn Reson Med. 1993;29:99-106.
Beckmann N, Tigani B, Ekatodramis D, Borer R, Mazzoni L, Fozard JR. Pulmonary edema induced by allergen challenge in the rat: noninvasive assessment by magnetic resonance imaging. Magn Reson Med. 2001;45:88-95.
Tibiletti M, Kjørstad Å, Bianchi A, Schad LR, Stiller D, Rasche V. Multistage self-gated lung imaging in small rodents: Multistage Self-Gated Lung Imaging in Small Rodents. Magn Reson Med. 2016;75:2448-2454.
Tibiletti M, Bianchi A, Stiller D, Rasche V. Pulmonary perfusion quantification with flow-sensitive inversion recovery (FAIR) UTE MRI in small animal imaging: FAIR-UTE. NMR Biomed. 2016;29:1791-1799.
Guo J, Hardie WD, Cleveland ZI, et al. Longitudinal free-breathing MRI measurement of murine lung physiology in a progressive model of lung fibrosis. J Appl Physiol. 2019;126:1138-1149.
Tibiletti M, Paul J, Bianchi A, et al. Multistage three-dimensional UTE lung imaging by image-based self-gating. Magn Reson Med. 2016;75:1324-1332.
Bianchi A, Tibiletti M, Kjørstad Å, et al. Three-dimensional accurate detection of lung emphysema in rats using ultra-short and zero echo time MRI. NMR Biomed. 2015;28:1471-1479.
Weiger M, Wu M, Wurnig MC, et al. Rapid and robust pulmonary proton ZTE imaging in the mouse. NMR Biomed. 2014;27:1129-1134.
Kobayashi N, Idiyatullin D, Corum C, Weber J, Garwood M, Sachdev D. SWIFT MRI enhances detection of breast cancer metastasis to the lung: detection of breast cancer metastasis to the lung with SWIFT. Magn Reson Med. 2015;73:1812-1819.
Kobayashi N, Lei J, Utecht L, Garwood M, Ingbar DH, Bhargava M. 3D cine magnetic resonance imaging of rat lung ARDS using gradient-modulated SWIFT with retrospective respiratory gating. Proc SPIE Int Soc Opt Eng. 2015;941718.
Glover GH, Pauly JM. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med. 1992;28:275-289.
Runge VM, Clanton JA, Partain CL, James AE. Respiratory gating in magnetic resonance imaging at 0.5 Tesla. Radiology. 1984;151:521-523.
Zurek M, Bessaad A, Cieslar K, Crémillieux Y. Validation of simple and robust protocols for high-resolution lung proton MRI in mice. Magn Reson Med. 2010;64:401-407.
Larson AC, Kellman P, Arai A, et al. Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI. Magn Reson Med. 2005;53:159-168.
Balasch A, Metze P, Stumpf K, et al. 2D ultrashort echo-time functional lung imaging. J Magn Reson Imaging. 2020;52:1637-1644.
Fischer A, Weick S, Ritter CO, et al. SElf-gated Non-Contrast-Enhanced FUnctional Lung imaging (SENCEFUL) using a quasi-random fast low-angle shot (FLASH) sequence and proton MRI. NMR Biomed. 2014;27:907-917.
Wundrak S, Paul J, Ulrici J, et al. Golden ratio sparse MRI using tiny golden angles. Magn Reson Med. 2016;75:2372-2378.
Li H, Metze P, Abaei A, et al. Feasibility of real-time cardiac MRI in mice using tiny golden angle radial sparse. NMR Biomed. 2020;33(7):e4300.
Duyn JH, Yang Y, Frank JA, van der Veen JW. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson. 1998;132:150-153.
Paul J, Divkovic E, Wundrak S, et al. High-resolution respiratory self-gated golden angle cardiac MRI: Comparison of self-gating methods in combination with k-t SPARSE SENSE. Magn Reson Med. 2015;73:292-298.
Weick S, Breuer FA, Ehses P, et al. DC-gated high resolution three-dimensional lung imaging during free-breathing. J Magn Reson Imaging. 2013;37:727-732.
Rasche V, Binner L, Cavagna F, et al. Whole-heart coronary vein imaging: A comparison between non-contrast-agent-and contrast-agent-enhanced visualization of the coronary venous system. Magn Reson Med. 2007;57:1019-1026.
Hatabu H, Alsop DC, Listerud J, Bonnet M, Gefter WB. T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. Eur J Radiol. 1999;29:245-252.
Myronenko A. MIRT - Medical Image Registration Toolbox for Matlab. https://sites.google.com/site/myronenko/research/mirt. Accessed August 20, 2018.
Zapke M, Topf H-G, Zenker M, et al. Magnetic resonance lung function-a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial. Respir Res. 2006;7(1):106.
Kjørstad A, Corteville DM, Fischer A, et al. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI. Magn Reson Med. 2014;72:558-562.
Togao O, Ohno Y, Dimitrov I, Hsia CC, Takahashi M. Ventilation/perfusion imaging of the lung using ultra-short echo time (UTE) MRI in an animal model of pulmonary embolism. J Magn Reson Imaging. 2011;34:539-546.
Wang F, Akashi K, Murakami Y, et al. Detection of lung tumors in mice using a 1-Tesla compact magnetic resonance imaging system. PLoS ONE. 2014;9:e94945.
Krupnick AS, Tidwell VK, Engelbach JA, et al. Quantitative monitoring of mouse lung tumors by magnetic resonance imaging. Nat Protoc. 2012;7:128-142.
Zhou X, Al-Hashem R, Ji H, Albert M, Wong K-K, Sun Y. Magnetic resonance imaging of the response of a mouse model of non-small cell lung cancer to tyrosine kinase inhibitor treatment. Comp Med. 2008;58(3):276-281.
Imai H, Matsumoto H, Miyakoshi E, Okumura S, Fujiwara H, Kimura A. Regional fractional ventilation mapping in spontaneously breathing mice using hyperpolarized 129Xe MRI. NMR Biomed. 2015;28:24-29.
Nouls J, Fanarjian M, Hedlund L, Driehuys B. A constant-volume ventilator and gas recapture system for hyperpolarized gas MRI of mouse and rat lungs. Concepts Magn Reson Part B Magn Reson Eng. 2011;39B:78-88.
Fox MS, Gaudet JM, Foster PJ. Fluorine-19 MRI contrast agents for cell tracking and lung imaging. Magn Reson Insights. 2016;8(Suppl 1):53-67.
Kuethe DO, Caprihan A, Gach HM, Lowe IJ, Fukushima E. Imaging obstructed ventilation with NMR using inert fluorinated gases. J Appl Physiol. 2000;88:2279-2286.
Zurek M, Sladen L, Johansson E, et al. Assessing the relationship between lung density and function with oxygen-enhanced magnetic resonance imaging in a mouse model of emphysema. PLoS ONE. 2016;11:e0151211.
Zurek M, Johansson E, Risse F, Alamidi D, Olsson LE, Hockings PD. Accurate T 1 mapping for oxygen-enhanced MRI in the mouse lung using a segmented inversion-recovery ultrashort echo-time sequence. Magn Reson Med. 2014;71:2180-2185.
Tibiletti M, Rasche V. Respiratory self-gated estimation of gas/tissue fractions with SF6 and proton lung imaging in free breathing mice. In: ISMRM 25th Annual Meeting & Exhibition, Honolulu; 2017.
Vasilescu D, Klinge C, Knudsen L, et al. Stereological assessment of mouse lung parenchyma via non-destructive multiscale micro CT imaging validated by light microscopic histology. J Appl Physiol. 2013;114:716-724.
Lopera D, Naranjo T, Hidalgo JM, et al. Pulmonary abnormalities in mice with paracoccidioidomycosis: a sequential study comparing high resolution computed tomography and pathologic findings. PLoS Negl Trop Dis. 2010;4:e726.
Mistry NN, Pollaro J, Song J, De Lin M, Johnson GA. Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI. Magn Reson Med. 2008;59:289-297.
Liu H-L, Pu Y, Liu Y, et al. Cerebral blood flow measurement by dynamic contrast MRI using singular value decomposition with an adaptive threshold. Magn Reson Med. 1999;42:167-172.
Kjørstad Å, Corteville DMR, Henzler T, Schmid-Bindert G, Zöllner FG, Schad LR. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T. Z Für Med Phys. 2015;25:326-332.
Kolodziej M, de Veer MJ, Cholewa M, Egan GF, Thompson BR. Lung function imaging methods in cystic fibrosis pulmonary disease. Respir Res. 2017;18:1-11.
Bauman G, Puderbach M, Heimann T, et al. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients. Eur J Radiol. 2013;82:2371-2377.
Hopkins SR, Prisk GK. Lung perfusion measured using magnetic resonance imaging: New tools for physiological insights into the pulmonary circulation. J Magn Reson Imaging. 2010;32:1287-1301.
Togao O, Tsuji R, Ohno Y, Dimitrov I, Takahashi M. Ultrashort echo time (UTE) MRI of the lung: Assessment of tissue density in the lung parenchyma. Magn Reson Med. 2010;64:1491-1498.
Olsson LE, Lindahl M, Önnervik P-O, et al. Measurement of MR signal and T2* in lung to characterize a tight skin mouse model of emphysema using single-point imaging. J Magn Reson Imaging. 2007;25:488-494.
Guo J, Cao X, Cleveland ZI, Woods JC. Murine pulmonary imaging at 7T: and T 1 with anisotropic UTE. Magn Reson Med. 2018;79:2254-2264.
Olsson LE, Hockings PD. In vivo measurements of T2 relaxation time of mouse lungs during inspiration and expiration. PLoS ONE. 2016;11:e0166879.
Fyrdahl A, Holst K, Caidahl K, Ugander M, Sigfridsson A. Generalization of three-dimensional golden-angle radial acquisition to reduce eddy current artifacts in bSSFP CMR imaging. Magn Reson Mater Phys Biol Med. 2021;34:109-118.
Chan RW, Ramsay EA, Cunningham CH, Plewes DB. Temporal stability of adaptive 3D radial MRI using multidimensional golden means. Magn Reson Med. 2009;61:354-363.
Akçakaya M, Moeller S, Weingärtner S, Uğurbil K. Scan-specific robust artificial-neural-networks for k-space interpolation (RAKI) reconstruction: Database-free deep learning for fast imaging. Magn Reson Med. 2019;81:439-453.
Küstner T, Armanious K, Yang J, Yang B, Schick F, Gatidis S. Retrospective correction of motion-affected MR images using deep learning frameworks. Magn Reson Med. 2019;82:1527-1540.