Advanced Deep Learning Approach to Automatically Segment Malignant Tumors and Ablation Zone in the Liver With Contrast-Enhanced CT.

U-Net ablation zone computed tomography liver cancer segmentation

Journal

Frontiers in oncology
ISSN: 2234-943X
Titre abrégé: Front Oncol
Pays: Switzerland
ID NLM: 101568867

Informations de publication

Date de publication:
2021
Historique:
received: 18 02 2021
accepted: 28 06 2021
entrez: 2 8 2021
pubmed: 3 8 2021
medline: 3 8 2021
Statut: epublish

Résumé

Liver cancer is one of the most commonly diagnosed cancer, and energy-based tumor ablation is a widely accepted treatment. Automatic and robust segmentation of liver tumors and ablation zones would facilitate the evaluation of treatment success. The purpose of this study was to develop and evaluate an automatic deep learning based method for (1) segmentation of liver and liver tumors in both arterial and portal venous phase for pre-treatment CT, and (2) segmentation of liver and ablation zones in both arterial and portal venous phase for after ablation treatment. 252 CT images from 63 patients undergoing liver tumor ablation at a large University Hospital were retrospectively included; each patient had pre-treatment and post-treatment multi-phase CT images. 3D voxel-wise manual segmentation of the liver, tumors and ablation region by the radiologist provided reference standard. Deep learning models for liver and lesion segmentation were initially trained on the public Liver Tumor Segmentation Challenge (LiTS) dataset to obtain base models. Then, transfer learning was applied to adapt the base models on the clinical training-set, to obtain tumor and ablation segmentation models both for arterial and portal venous phase images. For modeling, 2D residual-attention Unet (RA-Unet) was employed for liver segmentation and a multi-scale patch-based 3D RA-Unet for tumor and ablation segmentation. On the independent test-set, the proposed method achieved a dice similarity coefficient (DSC) of 0.96 and 0.95 for liver segmentation on arterial and portal venous phase, respectively. For liver tumors, the model on arterial phase achieved detection sensitivity of 71%, DSC of 0.64, and on portal venous phase sensitivity of 82%, DSC of 0.73. For liver tumors >0.5cm The proposed deep learning approach can provide automated segmentation of liver tumors and ablation zones on multi-phase (arterial and portal venous) and multi-time-point (before and after treatment) CT enabling quantitative evaluation of treatment success.

Identifiants

pubmed: 34336661
doi: 10.3389/fonc.2021.669437
pmc: PMC8320434
doi:

Types de publication

Journal Article

Langues

eng

Pagination

669437

Informations de copyright

Copyright © 2021 He, Liu, Shahzad, Reimer, Thiele, Niehoff, Wybranski, Bunck, Zhang and Perkuhn.

Déclaration de conflit d'intérêts

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Références

Cancer Imaging. 2019 Feb 27;19(1):11
pubmed: 30813956
Radiology. 1991 Feb;178(2):493-7
pubmed: 1846240
Radiol Artif Intell. 2019 Mar 13;1(2):180014
pubmed: 33937787
Oncotarget. 2016 Aug 9;7(32):52307-52316
pubmed: 27447571
J Vasc Interv Radiol. 2014 Nov;25(11):1691-705.e4
pubmed: 25442132
Cancer Imaging. 2019 Apr 26;19(1):21
pubmed: 31027510
Ann Oncol. 2016 Aug;27(8):1386-422
pubmed: 27380959
Radiol Oncol. 2020 Feb 12;54(1):57-61
pubmed: 32053495
Lancet. 2018 Mar 31;391(10127):1301-1314
pubmed: 29307467
Ann Surg. 2007 Jan;245(1):36-43
pubmed: 17197963
J Surg Oncol. 2016 Mar;113(3):296-303
pubmed: 26659586
Front Bioeng Biotechnol. 2020 Dec 23;8:605132
pubmed: 33425871
IEEE Trans Med Imaging. 2018 Dec;37(12):2663-2674
pubmed: 29994201
Radiology. 2010 Dec;257(3):674-84
pubmed: 20829538
Med Oncol. 2020 Apr 7;37(5):41
pubmed: 32266568
Sci Rep. 2016 Apr 15;6:24454
pubmed: 27079888
Med Image Anal. 2010 Feb;14(1):13-20
pubmed: 19828356
CA Cancer J Clin. 2018 Nov;68(6):394-424
pubmed: 30207593
IEEE Trans Med Imaging. 2020 May;39(5):1316-1325
pubmed: 31634827

Auteurs

Kan He (K)

Department of Radiology, The First Hospital of Jilin University, Changchun, China.

Xiaoming Liu (X)

College of Electronic Science and Engineering, Jilin University, Changchun, China.

Rahil Shahzad (R)

Innovative Technologies, Philips Healthcare, Aachen, Germany.
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Robert Reimer (R)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Frank Thiele (F)

Innovative Technologies, Philips Healthcare, Aachen, Germany.
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Julius Niehoff (J)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Christian Wybranski (C)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Alexander C Bunck (AC)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Huimao Zhang (H)

Department of Radiology, The First Hospital of Jilin University, Changchun, China.

Michael Perkuhn (M)

Innovative Technologies, Philips Healthcare, Aachen, Germany.
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Classifications MeSH