The clinical outcomes of scaphoid nonunion treated with a precisely processed autologous bone screw: a case series.


Journal

Archives of orthopaedic and trauma surgery
ISSN: 1434-3916
Titre abrégé: Arch Orthop Trauma Surg
Pays: Germany
ID NLM: 9011043

Informations de publication

Date de publication:
Feb 2023
Historique:
received: 26 02 2021
accepted: 27 07 2021
pubmed: 5 8 2021
medline: 16 2 2023
entrez: 4 8 2021
Statut: ppublish

Résumé

Metal implants and bioabsorbable implants are frequently used in orthopaedic surgery, but they have some disadvantages. The usefulness of autologous bone has been described, and a method to precisely process autologous bone into implants such as screws and apply the implants clinically has been desired. We created a new system for manufacturing autologous bone screws during surgery and report five cases of scaphoid nonunion treated with precise autologous bone screws made from the tibial cortex using the new system. From 2012 through 2017, seven patients were diagnosed with scaphoid nonunion at our hospital and based on the inclusion/exclusion criteria, five of them were analyzed herein. The surgery was performed according to Zaidemberg's technique. The bone screw in each case was made from autologous tibial cortex using a numerically controlled lathe (model MTS4, Nano Co., Yokohama, Japan) under sterile conditions. The change in each patient's modified Mayo wrist score between the preoperative examination and at the final survey was determined, as were complications. The median modified Mayo wrist score improved significantly from 65 to 95 points. All patients who were followed for > 2 years fused at a median duration of 3.5 months. Bone regeneration was confirmed at the donor sites in all cases. One fracture at the donor site occurred as a severe complication. Precisely shaped autologous bone screws manufactured by a computer-assisted machine, together with a vascularized bone graft, may be a useful technique for treating scaphoid nonunions; these screws had good stability and bone replacement. Careful observation of the donor site is required. IV.

Identifiants

pubmed: 34347123
doi: 10.1007/s00402-021-04092-8
pii: 10.1007/s00402-021-04092-8
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

627-635

Informations de copyright

© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Références

Blasier DR, Bucholtz R, Cole W et al (1997) Bioabsorbable implants: applications in orthopaedic surgery. Instr Course Lect 46:531–546
Fayad LM, Patra A, Fishman EK (2009) Value of 3D CT in defining skeletal complications of orthopedic hardware in the postoperative patient. AJR Am J Roentgenol 193:1155–1163
doi: 10.2214/AJR.09.2610 pubmed: 19770342
Hofmann GO (1995) Biodegradable implants in traumatology: a review on the state-of-the-art. Arch Orthop Trauma Surg 114:123–132
doi: 10.1007/BF00443385 pubmed: 7619632
Akmaz I, Kiral A, Pehlivan O et al (2004) Biodegradable implants in the treatment of scaphoid nonunions. Int Orthop 28:261–266
doi: 10.1007/s00264-004-0580-z pubmed: 15309325 pmcid: 3456976
Kujala S, Raatikainen T, Kaarela O et al (2004) Successful treatment of scaphoid fractures and nonunions using bioabsorbable screws: report of six cases. J Hand Surg Am 24:68–73
doi: 10.1016/j.jhsa.2003.09.009
Yi W, Muguo S, Yongquing X et al (2016) Absorbable scaphoid screw development: a comparative study on biomechanics. Ther Clin Risk Manag 12:643–650
Böstman O, Hirvensalo E, Mäkinen J et al (1990) Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72:592–596
doi: 10.1302/0301-620X.72B4.2199452 pubmed: 2199452
Konan S, Haddad FS (2009) The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery. Knee Surg Sports Traumatol Arthrosc 17:293–297
doi: 10.1007/s00167-008-0684-x pubmed: 19083204
Imade S, Mori R, Uchio U (2012) Treatment of scaphoid nonunion using an autologous bone screw. J Hand Surg Eur 37:899–900
doi: 10.1177/1753193412436394
Imade S, Mori R, Uchio Y et al (2009) Effect of implant surface roughness on bone fixation: the differences between bone and metal pegs. J Orthop Sci 14:652–657
doi: 10.1007/s00776-009-1369-0 pubmed: 19802680
Kono M, Mori R, Uchio Y (2012) Bone screws have advantages in repair of experimental osteochondreal fragments. Clin Orthop Relat Res 470:2043–2050
doi: 10.1007/s11999-011-2175-5 pubmed: 22081300
Langer MF, Unglaub F, Breiter S et al (2019) Anatomy and pathobiomechanics of the scaphoid. Unfallchirurg 122(3):170–181
doi: 10.1007/s00113-018-0597-1 pubmed: 30607486
Hove LM (1999) Epidemiology of scaphoid fractures in Bergen, Norway. Scand J Plast Reconstr Surg Hand Surg 33:423–426
doi: 10.1080/02844319950159145 pubmed: 10614752
Kawamura K, Chung KC (2008) Treatment of scaphoid fractures and nonunions. J Hand Surg Am 33:988–997
doi: 10.1016/j.jhsa.2008.04.026 pubmed: 18656779 pmcid: 4405116
Quadlbauer S, Pezzei C, Jurkowitsch J et al (2019) Palmar angular stable plate fixation of nonunions and comminuted fractures of the scaphoid. Oper Orthop Traumatol 31:433–446
doi: 10.1007/s00064-019-00623-0 pubmed: 31435702
Mehling IM, Arsalan-Werner A, Wingenbach V et al (2019) Practicability of a locking plate for difficult pathologies of the scaphoid. Arch Orthop Trauma Surg 139:1161–1169
doi: 10.1007/s00402-019-03196-6 pubmed: 31123820
Quadlbauer S, Pezzei C, Beer T et al (2019) Treatment of scaphoid waist nonunion by one, two headless compression screws or plate with or without additional extracorporeal shockwave therapy. Arch Orthop Trauma Surg 139:281–293
doi: 10.1007/s00402-018-3087-6 pubmed: 30523445
Murray G (1934) Bone-graft for non-union of the carpal scaphoid. Br J Surg 22:63–68
doi: 10.1002/bjs.1800228508
Russe O (1960) Fracture of the carpal navicular. Diagnosis, non-operative treatment, and operative treatment. J Bone Joint Surg Am 42:759–768
doi: 10.2106/00004623-196042050-00002 pubmed: 13854612
Munk B, Larsen CF (2004) Bone grafting the scaphoid nonunion: a systematic review of 147 publications including 5,246 cases of scaphoid nonunion. Acta Orthop Scand 75:618–629
doi: 10.1080/00016470410001529 pubmed: 15513497
Imade S, Uchio Y, Ozoe N (2012) Superior fixation of machine-made bone pegs over handmade bone pegs. J Orthop Sci 17:619–625
doi: 10.1007/s00776-012-0251-7 pubmed: 22692789
Zaidemberg C, Siebert JW, Angrigiani C (1991) A new vascularized bone graft for scaphoid nonunion. J Hand Surg Am 16:474–478
doi: 10.1016/0363-5023(91)90017-6 pubmed: 1861030
Amadio PC, Berquist TH, Smith DK et al (1989) Scaphoid malunion. J Hand Surg Am 14:679–687
doi: 10.1016/0363-5023(89)90191-3 pubmed: 2787817
Düppe H, Johnell O, Lundborg G et al (1994) Long-term results of fracture of the scaphoid. A follow-up study of more than thirty years. J Bone Joint Surg Am 76:249–252
doi: 10.2106/00004623-199402000-00012 pubmed: 8113260
Filan SL, Herbert TJ (1996) Herbert screw fixation of scaphoid fractures. J Bone Joint Surg 78-B:519–529
doi: 10.1302/0301-620X.78B4.0780519
Nagatani T, Mori R, Wang Y et al (2010) Optimum predrilled hole size for bone screws used in osteochondral fixation: in vitro biomechanical study and clinical case. J Orthop Sci 15:245–250
doi: 10.1007/s00776-009-1442-8 pubmed: 20358339
Izawa H, Hachiya Y, Kawai T et al (2001) The effect of heat-treated human bone morphogenetic protein on clinical implantation. Clin Orthop Pelat Res 390:252–258
doi: 10.1097/00003086-200109000-00029
Obwegeser JA (1994) Bioconvertible screws made of allogenic cortical bone for osteosynthesis following sagittal split ramus osteotomy without postoperative immobilization. J Craniomaxillofac Surg 22:63–75
doi: 10.1016/S1010-5182(05)80013-7 pubmed: 8021321
Rano JA, Savoy-Moore RT, Fallat LM (2002) Strength comparison of allogenic bone screws, bioabsorbable screws, and stainless steel screw fixation. J Foot Ankle Surg 40:351–356
doi: 10.1016/S1067-2516(01)80002-8
Hong Y, Brent GP, Stuart DM et al (2006) Biomechanical analysis of tibial strength after harvesting unicortical tibial grafts from two different sites. Foot Ankle Int 27:190–195
doi: 10.1177/107110070602700307 pubmed: 16539901
Siddesh ND, Hitesh HS, Benjamin J (2010) Donor site morbidity following the harvesting of cortical bone graft from the tibia in children. J Child Orthop 4:417–421
doi: 10.1007/s11832-010-0277-3
Hong Y, Krishn MS, Brent GP et al (2008) Biomechanical analysis of tibial strength after harvesting unicortical tibial grafts of two different lengths. Foot Ankle Int 29:726–729
doi: 10.3113/FAI.2008.0726 pubmed: 18785424

Auteurs

Takuya Manako (T)

Department of Orthopaedic Surgery, Faculty of Medicine, Shimane University, 89-1, Enya, Izumo, Shimane, 693-8501, Japan. manako@med.shimane-u.ac.jp.

Shinji Imade (S)

Department of Orthopaedic Surgery, Faculty of Medicine, Shimane University, 89-1, Enya, Izumo, Shimane, 693-8501, Japan.

Nobuo Yamagami (N)

Department of Orthopaedic Surgery, Faculty of Medicine, Shimane University, 89-1, Enya, Izumo, Shimane, 693-8501, Japan.

Soichiro Yamamoto (S)

Department of Orthopaedic Surgery, Faculty of Medicine, Shimane University, 89-1, Enya, Izumo, Shimane, 693-8501, Japan.

Yuji Uchio (Y)

Department of Orthopaedic Surgery, Faculty of Medicine, Shimane University, 89-1, Enya, Izumo, Shimane, 693-8501, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH