Supercritical fluid extraction-supercritical fluid chromatography of saliva: Single-quadrupole mass spectrometry monitoring of caffeine for gastric emptying studies
carbon dioxide-based separation
online sample preparation
saliva
supercritical fluid chromatography
supercritical fluid extraction
Journal
Journal of separation science
ISSN: 1615-9314
Titre abrégé: J Sep Sci
Pays: Germany
ID NLM: 101088554
Informations de publication
Date de publication:
Oct 2021
Oct 2021
Historique:
revised:
02
08
2021
received:
04
06
2021
accepted:
02
08
2021
pubmed:
7
8
2021
medline:
28
1
2022
entrez:
6
8
2021
Statut:
ppublish
Résumé
Saliva is an attractive sampling matrix for measuring various endogenous and exogeneous substances but requires sample treatment prior to chromatographic analysis. Exploiting supercritical CO
Identifiants
pubmed: 34355502
doi: 10.1002/jssc.202100443
doi:
Substances chimiques
Caffeine
3G6A5W338E
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
3700-3716Subventions
Organisme : Deutsche Forschungsgemeinschaft
Organisme : We acknowledge support by the German Research Foundation and the Open Access Publication Fund of the Thueringer Universitaets- und Landesbibliothek Jena.
Informations de copyright
© 2021 The Authors. Journal of Separation Science published by Wiley-VCH GmbH.
Références
Medvedovici A, Bacalum E, David V. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques. Biomed Chromatogr. 2018;32:e4137.
Artika IM, Ma'roef CN. Laboratory biosafety for handling emerging viruses. Asian Pac J Trop Biomed. 2017;7:483-91.
Niu Z, Zhang W, Yu C, Zhang J, Wen Y. Recent advances in biological sample preparation methods coupled with chromatography, spectrometry and electrochemistry analysis techniques. TrAC Trends Anal Chem. 2018;102:123-46.
Elmongy H, Abdel-Rehim M. Saliva as an alternative specimen to plasma for drug bioanalysis: A review. TrAC Trends Anal Chem. 2016;83:70-9.
Hutchinson L, Sinclair M, Reid B, Burnett K, Callan B. A descriptive systematic review of salivary therapeutic drug monitoring in neonates and infants. Br J Clin Pharmacol. 2018;84:1089-108.
Bhowmick S, Kundu AK, Adhikari J, Chatterjee D, Iglesias M, Nriagu J, Guha Mazumder DN, Shomar B, Chatterjee D. Assessment of toxic metals in groundwater and saliva in an arsenic affected area of West Bengal, India: A pilot scale study. Environ Res. 2015;142:328-36.
Wood RC, Luabeya AK, Weigel KM, Wilbur AK, Jones-Engel L, Hatherill M, Cangelosi GA. Detection of Mycobacterium tuberculosis DNA on the oral mucosa of tuberculosis patients. Sci Rep. 2015;5:8668.
Lightbody KL, Matthews JB, Kemp-Symonds JG, Lambert PA, Austin CJ. Use of a saliva-based diagnostic test to identify tapeworm infection in horses in the UK. Equine Vet J. 2018;50:213-9.
Kaur J, Jacobs R, Huang Y, Salvo N, Politis C. Salivary biomarkers for oral cancer and pre-cancer screening: A review. Clin Oral Investig. 2018;22:633-40.
Pletzer B, Harris T-A, Scheuringer A, Hidalgo-Lopez E. The cycling brain: Menstrual cycle related fluctuations in hippocampal and fronto-striatal activation and connectivity during cognitive tasks. Neuropsychopharmacology 2019;1-9.
Prasad S, Tyagi AK, Aggarwal BB. Detection of inflammatory biomarkers in saliva and urine: Potential in diagnosis, prevention, and treatment for chronic diseases. Exp Biol Med. 2016;241:783-99.
Numako M, Toyo'oka T, Noge I, Kitagawa Y, Mizuno H, Todoroki K. Risk assessment of diabetes mellitus using dried saliva spot followed by ultra-performance liquid chromatography with fluorescence and mass spectrometry. Microchem J. 2018;142:202-7.
Huan T, Tran T, Zheng J, Sapkota S, MacDonald SW, Camicioli R, Dixon RA, Li L. Metabolomics analyses of saliva detect novel biomarkers of Alzheimer's disease. J Alzheimer's Dis. 2018;65:1401-16.
Bucardo F, Nordgren J, Reyes Y, Gonzalez F, Sharma S, Svensson L. The Lewis A phenotype is a restriction factor for Rotateq and Rotarix vaccine-take in Nicaraguan children. Sci Rep. 2018;8:1502.
Bellagambi FG, Lomonaco T, Salvo P, Vivaldi F, Hangouët M, Ghimenti S, Biagini D, Di Francesco F, Fuoco R, Errachid A. Saliva sampling: Methods and devices. An overview. TrAC Trends Anal Chem. 2020;124:115781.
Niedrig M, Patel P, El Wahed AA, Schädler R, Yactayo S. Find the right sample: A study on the versatility of saliva and urine samples for the diagnosis of emerging viruses. BMC Infect Dis. 2018;18:707.
Czumbel LM, Kiss S, Farkas N, Mandel I, Hegyi A, Nagy Á, Lohinai Z, Szakács Z, Hegyi P, Steward MC, Varga G. Saliva as a candidate for COVID-19 diagnostic testing: A meta-analysis. Front Med. 2020;7:1-10.
Huang N, Pérez P, Kato T, Mikami Y, Okuda K, Gilmore RC, Conde CD, Gasmi B, Stein S, Beach M, Pelayo E, Maldonado JO, Lafont BA, Jang S-I, Nasir N, Padilla RJ, Murrah VA, Maile R, Lovell W, Wallet SM, Bowman NM, Meinig SL, Wolfgang MC, Choudhury SN, Novotny M, Aevermann BD, Scheuermann RH, Cannon G, Anderson CW, Lee RE, Marchesan JT, Bush M, Freire M, Kimple AJ, Herr DL, Rabin J, Grazioli A, Das S, French BN, Pranzatelli T, Chiorini JA, Kleiner DE, Pittaluga S, Hewitt SM, Burbelo PD, Chertow D, Frank K, Lee J, Boucher RC, Teichmann SA, Warner BM, Byrd KM. SARS-CoV-2 infection of the oral cavity and saliva. Nat Med. 2021;27:892-903.
Pedrosa PBS, Cardoso TAO. Viral infections in workers in hospital and research laboratory settings: A comparative review of infection modes and respective biosafety aspects. Int J Infect Dis. 2011;15:e366-76.
van den Elsen SHJ, van der Laan T, Akkerman OW, van der Zanden AGM, Alffenaar J-WC, van Soolingen D. Membrane filtration is suitable for reliable elimination of Mycobacterium tuberculosis from saliva for therapeutic drug monitoring. J Clin Microbiol. 2017;55:3292-3.
Singh K. It's time for a centralized registry of laboratory-acquired infections. Nat Med. 2011;17:919.
Slots J, Slots H. Bacterial and viral pathogens in saliva: Disease relationship and infectious risk. Periodontol 2000. 2011;55:48-69.
Zoccali M, Donato P, Mondello L. Recent advances in the coupling of carbon dioxide-based extraction and separation techniques. TrAC Trends Anal Chem. 2019;116:158-65.
Medeiros-Neves B, Diel KAP, Eifler-Lima VL, Teixeira HF, Cassel E, Figueiró Vargas RM, von Poser GL. Influence of the supercritical CO2 extraction in the stability of the coumarins of Pterocaulon lorentzii (Asteraceae). J CO2 Util. 2020;39:101165.
Ribeiro N, Soares GC, Santos-Rosales V, Concheiro A, Alvarez-Lorenzo C, García-González CA, Oliveira AL. A new era for sterilization based on supercritical CO2 technology. J Biomed Mater Res Part B Appl Biomater. 2019;jbm.b.34398.
Wicker AP, Tanaka K, Nishimura M, Chen V, Ogura T, Hedgepeth W, Schug KA. Multivariate approach to on-line supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry method development. Anal Chim Acta 2020;1127:282-94.
Sánchez-Camargo Adel P, Parada-Alonso F, Ibáñez E, Cifuentes A. Recent applications of on-line supercritical fluid extraction coupled to advanced analytical techniques for compounds extraction and identification. J Sep Sci. 2019;42:243-57.
Zoccali M, Giuffrida D, Sala F, Giofr SV, Mondello L. Carotenoids and apocarotenoids determination in intact human blood samples by online supercritical fl uid extraction-supercritical fluid chromatography-tandem mass spectrometry. Anal Chim Acta 2018, in press, 1-8.
Uchikata T, Matsubara A, Fukusaki E, Bamba T. High-throughput phospholipid profiling system based on supercritical fluid extraction-supercritical fluid chromatography/mass spectrometry for dried plasma spot analysis. J Chromatogr A. 2012;1250:69-75.
Suzuki M, Nishiumi S, Kobayashi T, Sakai A, Iwata Y, Uchikata T, Izumi Y, Azuma T, Bamba T, Yoshida M. Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom. 2017;31:886-94.
Hofstetter R, Fassauer GM, Link A. Supercritical fluid extraction (SFE) of ketamine metabolites from dried urine and on-line quantification by supercritical fluid chromatography and single mass detection (on-line SFE-SFC-MS). J Chromatogr B. 2018;1076:77-83.
Zoccali M, Giuffrida D, Salafia F, Rigano F, Dugo P, Casale M, Mondello L. Apocarotenoids profiling in different Capsicum species. Food Chem. 2021;334:127595.
Wicker AP, Carlton DD, Tanaka K, Nishimura M, Chen V, Ogura T, Hedgepeth W, Schug KA. On-line supercritical fluid extraction-Supercritical fluid chromatography-mass spectrometry of polycyclic aromatic hydrocarbons in soil. J Chromatogr B. 2018;1086:82-8.
Losacco GL, Veuthey J-L, Guillarme D. Supercritical fluid chromatography-mass spectrometry: Recent evolution and current trends. TrAC Trends Anal Chem. 2019;118:731-8.
Liang Y, Zhou T. Recent advances of online coupling of sample preparation techniques with ultra high performance liquid chromatography and supercritical fluid chromatography. J Sep Sci. 2019;42:226-42.
Liu J, Ji F, Chen F, Guo W, Yang M, Huang S, Zhang F, Liu Y. Determination of garlic phenolic compounds using supercritical fluid extraction coupled to supercritical fluid chromatography/tandem mass spectrometry. J Pharm Biomed Anal. 2018;159:513-23.
Pauk V, Lemr K. Forensic applications of supercritical fluid chromatography-mass spectrometry. J Chromatogr B. 2018;1086:184-96.
Prokopczyk B, Wu M, Cox JE, Hoffmann D. Bioavailability of tobacco-specific N-nitrosamines to the snuff dipper. Carcinogenesis 1992;13:863-6.
World Health Organization, Caffeine (ICSC 0405). INCHEM. 1998.
Yu T, Balch AH, Ward RM, Korgenski EK, Sherwin CMT. Incorporating pharmacodynamic considerations into caffeine therapeutic drug monitoring in preterm neonates. BMC Pharmacol Toxicol. 2016;17:22.
Lee TC, Charles BG, Steer PA, Flenady VJ. Saliva as a valid alternative to serum in monitoring intravenous caffeine treatment for apnea of prematurity. Ther Drug Monit. 1996;18.
Begas E, Kouvaras E, Tsakalof AK, Bounitsi M, Asprodini EK. Development and validation of a reversed-phase HPLC method for CYP1A2 phenotyping by use of a caffeine metabolite ratio in saliva. Biomed Chromatogr. 2015;29:1657-63.
Jordan NY, Mimpen JY, van den Bogaard WJM, Flesch FM, van de Meent MHM, Torano JS. Analysis of caffeine and paraxanthine in human saliva with ultra-high-performance liquid chromatography for CYP1A2 phenotyping. J Chromatogr B. 2015;995-996:70-3.
Schievano E, Finotello C, Navarini L, Mammi S. Quantification of caffeine in human saliva by nuclear magnetic resonance as an alternative method for cytochrome CYP1A2 phenotyping. Talanta 2015;140:36-41.
Urry E, Jetter A, Landolt H-P. Assessment of CYP1A2 enzyme activity in relation to type-2 diabetes and habitual caffeine intake. Nutr Metab (Lond). 2016;13:66.
Eaimtrakarn S, Rama Prasad YV, Puthli SP, Yoshikawa Y, Shibata N, Takada K. Evaluation of gastrointestinal transit characteristics of oral patch preparation using caffeine as a model drug in human volunteers. Drug Metab Pharmacokinet. 2002;17:284-91.
Muraoka M, Hu Z, Shimokawa T, Sekino S, Kurogoshi R, Kuboi Y, Yoshikawa Y, Takada K. Evaluation of intestinal pressure-controlled colon delivery capsule containing caffeine as a model drug in human volunteers. J Control Release 1998;52:119-29.
Sager M, Jedamzik P, Merdivan S, Grimm M, Schneider F, Kromrey M-L, Hasan M, Oswald S, Kühn J, Koziolek M, Weitschies W. Low dose caffeine as a salivary tracer for the determination of gastric water emptying in fed and fasted state: A MRI validation study. Eur J Pharm Biopharm. 2018;127:443-52.
Sager M, Schneider F, Jedamzik P, Wiedmann M, Schremmer E, Koziolek M, Weitschies W. Effect of coadministered water on the in vivo performance of oral formulations containing N-acetylcysteine: An in vitro approach using the dynamic open flow-through test apparatus. Mol Pharm. 2017;14:4272-80.
Sager M, Grimm M, Jedamzik P, Merdivan S, Kromrey M-L, Hasan M, Koziolek M, Tzvetkov MV, Weitschies W. Combined application of MRI and the salivary tracer technique to determine the in vivo disintegration time of immediate release formulation administered to healthy, fasted subjects. Mol Pharm. 2019;16:1782-6.
Rico-Gómez R, Nájera F, Manuel López-Romero J, Cañada-Rudner P. Solvent-free synthesis of thio-alkylxanthines from alkylxanthines using microwave irradiation. Heterocycles 2000;53:2275.
Manvar A, Shah A. Microwave-assisted chemistry of purines and xanthines. An overview. Tetrahedron 2013;69:8105-27.
U.S. Department of Health and Human Services Food and Drug Administration (FDA): Guidance for industry, Bioanalytical method validation. 2018.
European Medicines Agency, Guideline on bioanalytical method validation. Ref. number EMEA/CHMP/EWP/192217/2009, 2012, 1-23.
Lowes S, Hucker R, Jemal M, Marini JC, Rezende VM, Shoup R, Singhal P, Timmerman P, Yoneyama T, Weng N, Zimmer D. Tiered approaches to chromatographic bioanalytical method performance evaluation: Recommendation for best practices and harmonization from the global bioanalysis consortium harmonization team. AAPS J. 2015;17:17-23.
Timmerman P, Golob M, Goodman J, Knutsson M, Nelson R, Fjording MS, White S. Toward decision-based acceptance criteria for bioanalytical method validation: A proposal for discussion from the european bioanalysis forum. Bioanalysis 2018;10:1255-9.
Food and Drug Administration, Food-effect bioavailability and fed bioequivalence studies: Guidance for Industry. 2002.
European Medicines Agency, Guideline on the investigation of bioequivalence. Ref. number EMEA/CPMP/EWP/QWP/1401/98 Rev. 1/Corr, 2010, 1-27.
Gaussian Citation 2019 (Https://Gaussian.Com/Citation). n.d.
Aps JKM, Martens LC. Review: The physiology of saliva and transfer of drugs into saliva. Forensic Sci Int. 2005;150:119-31.
Pappa E, Kousvelari E, Vastardis H. Saliva in the “Omics” era: A promising tool in paediatrics. Oral Dis. 2019;25:16-25.
Sweeney EL, Al-Shehri SS, Cowley DM, Liley HG, Bansal N, Charles BG, Shaw PN, Duley JA, Knox CL. The effect of breastmilk and saliva combinations on the in vitro growth of oral pathogenic and commensal microorganisms. Sci Rep. 2018;8:15112.
Matczuk J, Żendzian-Piotrowska M, Maciejczyk M, Kurek K. Salivary lipids: A review. Adv Clin Exp Med. 2017;26:1023-31.
Theda C, Hwang SH, Czajko A, Loke YJ, Leong P, Craig JM. Quantitation of the cellular content of saliva and buccal swab samples. Sci Rep. 2018;8:6944.
Svan A, Hedeland M, Arvidsson T, Pettersson CE. The differences in matrix effect between supercritical fluid chromatography and reversed phase liquid chromatography coupled to ESI/MS. Anal Chim Acta 2018;1000:163-71.
Haglind A, Hedeland M, Arvidsson T, Pettersson CE. Major signal suppression from metal ion clusters in SFC/ESI-MS-Cause and effects. J Chromatogr B 2018;1084:96-105.
Tyśkiewicz K, Konkol M, Rój E. The application of supercritical fluid extraction in phenolic compounds: Isolation from natural plant materials. Molecules 2018;23:2625.
Sökmen M, Demir E, Alomar SY. Optimization of sequential supercritical fluid extraction (SFE) of caffeine and catechins from green tea. J Supercrit Fluids 2018;133:171-6.
Jokić S, Gagić T, Knez Ž, Šubarić D, Škerget M. Separation of active compounds from food by-product (cocoa shell) using subcritical water extraction. Molecules 2018;23:1408.
Ilgaz S, Sat IG, Polat A. Effects of processing parameters on the caffeine extraction yield during decaffeination of black tea using pilot-scale supercritical carbon dioxide extraction technique. J Food Sci Technol. 2018;55:1407-15.
Bermejo DV, Ibáñez E, Reglero G, Fornari T. Effect of cosolvents (ethyl lactate, ethyl acetate and ethanol) on the supercritical CO2 extraction of caffeine from green tea. J Supercrit Fluids 2016;107:507-12.
Tena MT, Valcárcel M. Fiber optic-based interface for on-line selective photometric determinations in solid samples by supercritical fluid extraction. J Chromatogr A 1996;753:299-305.
Sugiyama K, Saito M, Hondo T, Senda M. New double-stage separation analysis method-Directly coupled laboratory-scale supercritical fluid extraction-supercritical fluid chromatography, monitored with a multiwavelength ultraviolet detector. J Chromatogr A 1985;332:107-16.
dePaula J, Farah A. Caffeine consumption through coffee: Content in the beverage, metabolism, health benefits and risks. Beverages 2019;5:37.
Abrahamsson V, Henderson BL, Zhong F, Lin Y, Kanik I. Online supercritical fluid extraction and chromatography of biomarkers analysis in aqueous samples for in situ planetary applications. Anal Bioanal Chem. 2019, 8091-101. https://doi.org/10.1007/s00216-019-02189-z.
Hofstetter RK, Potlitz F, Schulig L, Kim S, Hasan M, Link A. Subcritical fluid chromatography at sub-ambient temperatures for the chiral resolution of ketamine metabolites with rapid-onset antidepressant effects. Molecules 2019;24:1927.
Sakai M, Hayakawa Y, Funada Y, Ando T, Fukusaki E, Bamba T. Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography. J Chromatogr A 2017;1515:218-31.
Sakai M, Hayakawa Y, Funada Y, Ando T, Fukusaki E, Bamba T. Development of a practical online supercritical fluid extraction-supercritical fluid chromatography/mass spectrometry system with an integrated split-flow method. J Chromatogr A 2019;1592:161-72.
West C, Khater S, Lesellier E. Characterization and use of hydrophilic interaction liquid chromatography type stationary phases in supercritical fluid chromatography. J Chromatogr A 2012;1250:182-95.
West C, Khalikova MA, Lesellier E, Héberger K. Sum of ranking differences to rank stationary phases used in packed column supercritical fluid chromatography. J Chromatogr A 2015;1409:241-50.
West C, Lemasson E, Bertin S, Hennig P, Lesellier E. An improved classification of stationary phases for ultra-high performance supercritical fluid chromatography. J Chromatogr A 2016;1440:212-28.
Upnmoor D, Brunner G. Investigation of retention behaviour in packed column SFC. Berichte der Bunsengesellschaft für Phys Chemie. 1989;93:1009-15.
Elisabeth P, Yoshioka M, Yamauchi Y, Saito M. Infrared and nuclear magnetic resonance spectrometry of caffeine in roasted coffee beans after separation by preparative supercritical fluid chromatography. Anal Sci. 1991;7:427-31.
Berger TA. Demonstration of high speeds with low pressure drops using 1.8 μm particles in SFC. Chromatographia 2010;72:597-602.
Hofstetter RK, Hasan M, Fassauer GM, Bock C, Surur AS, Behnisch S, Grathwol CW, Potlitz F, Oergel T, Siegmund W, Link A. Simultaneous quantification of acidic and basic flupirtine metabolites by supercritical fluid chromatography according to European Medicines Agency validation. J Chromatogr A 2019;1603:338-47.
Blanchard J, Weber CW, Shearer L-E. HPLC analysis of methylxanthines in human breast milk. J Chromatogr Sci. 1990;28:640-2.
Howard DL, Kjaergaard HG. Hydrogen bonding to divalent sulfur. Phys Chem Chem Phys. 2008;10:4113.
Nguyen D, Zandarashvili L, White MA, Iwahara J. Stereospecific effects of oxygen-to-sulfur substitution in DNA phosphate on ion pair dynamics and protein-DNA affinity. ChemBioChem 2016;17:1636-42.
Wennmohs F, Staemmler V, Schindler M. Theoretical investigation of weak hydrogen bonds to sulfur. J Chem Phys. 2003;119:3208-18.
Raposo F. Evaluation of analytical calibration based on least-squares linear regression for instrumental techniques: A tutorial review. TrAC Trends Anal Chem. 2016;77:167-85.
Wurtz N, Papa A, Hukic M, Di Caro A, Leparc-Goffart I, Leroy E, Landini MP, Sekeyova Z, Dumler JS, Bădescu D, Busquets N, Calistri A, Parolin C, Palù G, Christova I, Maurin M, La Scola B, Raoult D. Survey of laboratory-acquired infections around the world in biosafety level 3 and 4 laboratories. Eur J Clin Microbiol Infect Dis. 2016;35:1247-58.
Jafari MT, Rezaei B, Javaheri M. A new method based on electrospray ionisation ion mobility spectrometry (ESI-IMS) for simultaneous determination of caffeine and theophylline. Food Chemistry. 2011;126: 4:1964-1970. http://doi.org/10.1016/j.foodchem.2010.12.054.
Baranowski J, Pochopień G, Baranowska I. Determination of nicotine, cotinine and caffeine in meconium using high-performance liquid chromatography. Journal of Chromatography B: Biomedical Sciences and Applications. 1998;707: 1-2:317-321. http://doi.org/10.1016/s0378-4347(97)00619-1.
Peri-Okonny UL, Wang SX, Stubbs RJ, Guzman NA. Determination of caffeine and its metabolites in urine by capillary electrophoresis-mass spectrometry. ELECTROPHORESIS. 2005;26: 13:2652-2663. http://doi.org/10.1002/elps.200500231.
Timofeeva I, Medinskaia K, Nikolaeva L, Kirsanov D, Bulatov A Stepwise injection potentiometric determination of caffeine in saliva using single-drop microextraction combined with solvent exchange. Talanta. 2016;150: 655-660. http://doi.org/10.1016/j.talanta.2016.01.001.
Marchei E, Escuder D, Pallas CR, Garcia-Algar O, Gómez A, Friguls B, Pellegrini M, Pichini S. Simultaneous analysis of frequently used licit and illicit psychoactive drugs in breast milk by liquid chromatography tandem mass spectrometry. Journal of Pharmaceutical and Biomedical Analysis. 2011;55: 2:309-316. http://doi.org/10.1016/j.jpba.2011.01.028.
De Kesel Pieter MM, Lambert Willy E, Stove Christophe P. An optimized and validated SPE-LC-MS/MS method for the determination of caffeine and paraxanthine in hair. Talanta. 2015;144: 62-70. http://doi.org/10.1016/j.talanta.2015.05.084.
Lopez-Sanchez RdC, Lara-Diaz VJ, Aranda-Gutierrez A, Martinez-Cardona JA, Hernandez JA. HPLC Method for Quantification of Caffeine and Its Three Major Metabolites in Human Plasma Using Fetal Bovine Serum Matrix to Evaluate Prenatal Drug Exposure. Journal of Analytical Methods in Chemistry. 2018;2018: 1-11. http://doi.org/10.1155/2018/2085059.
Carvalho JJ, Weller MG, Panne U, Schneider RJ. Monitoring Caffeine in Human Saliva Using a Newly Developed ELISA. Analytical Letters. 2012;45: 17:2549-2561. http://doi.org/10.1080/00032719.2012.696226.
Xiong X-Q, Huang K-J, Xu C-X, Jin C-X, Zhai Q-G. Glassy carbon electrode modified with poly(taurine)/TiO2-graphene composite film for determination of acetaminophen and caffeine. Chemical Industry and Chemical Engineering Quarterly. 2013;19: 3:359-368. http://doi.org/10.2298/ciceq120325070x.
Hyötyläinen T, Sirén H, Riekkola M-L. Determination of morphine analogues, caffeine and amphetamine in biological fluids by capillary electrophoresis with the marker technique. Journal of Chromatography A. 1996;735: 1-2:439-447. https://doi.org/10.1016/0021-9673(96)00067-2.
Rybak ME, Pao C-I, Pfeiffer CM. Determination of urine caffeine and its metabolites by use of high-performance liquid chromatography-tandem mass spectrometry: estimating dietary caffeine exposure and metabolic phenotyping in population studies. Analytical and Bioanalytical Chemistry. 2014;406: 3:771-784. http://doi.org/10.1007/s00216-013-7506-9.
Ptolemy AS, Tzioumis E, Thomke A, Rifai S, Kellogg M. Quantification of theobromine and caffeine in saliva, plasma and urine via liquid chromatography-tandem mass spectrometry: A single analytical protocol applicable to cocoa intervention studies. Journal of Chromatography B. 2010;878: 3-4:409-416. http://doi.org/10.1016/j.jchromb.2009.12.019.
Pérez-Mart́inez I, Sagrado S, Medina-Hernández MJ. A rapid procedure for the determination of caffeine, theophylline and theobromine in urine by micellar liquid chromatography and direct sample injection. Analytica Chimica Acta. 1995;304: 2:195-201. http://doi.org/10.1016/0003-2670(94)00619-w.
Bispo MS, Veloso MCC, Pinheiro HLC, De Oliveira RFS, Reis JON, De Andrade JB. Simultaneous Determination of Caffeine, Theobromine, and Theophylline by High-Performance Liquid Chromatography. Journal of Chromatographic Science. 2002;40: 1:45-48. http://doi.org/10.1093/chromsci/40.1.45.
Goyal RN, Bishnoi S, Agrawal B. Electrochemical sensor for the simultaneous determination of caffeine and aspirin in human urine samples. Journal of Electroanalytical Chemistry. 2011;655: 2:97-102. http://doi.org/10.1016/j.jelechem.2011.03.008.
Zhao Yeping, Lunte CE. Determination of caffeine and its metabolites by micellar electrokinetic capillary electrophoresis. Journal of Chromatography B: Biomedical Sciences and Applications. 1997;688: 2:265-274. http://doi.org/10.1016/s0378-4347(96)00278-2.
Molaakbari Elahe, Mostafavi Ali, Beitollahi Hadi. Simultaneous electrochemical determination of dopamine, melatonin, methionine and caffeine. Sensors and Actuators B: Chemical. 2015;208: 195-203. http://doi.org/10.1016/j.snb.2014.10.130.
Wong Ademar, Santos Anderson Martin, Silva Tiago Almeida, Fatibello-Filho Orlando. Simultaneous determination of isoproterenol, acetaminophen, folic acid, propranolol and caffeine using a sensor platform based on carbon black, graphene oxide, copper nanoparticles and PEDOT:PSS. Talanta. 2018;183: 329-338. http://doi.org/10.1016/j.talanta.2018.02.066.