Bone marrow aspiration and biopsy: techniques and practice implications.
Bone marrow aspiration
Bone marrow biopsy
CT guidance
Fluoroscopy guidance
Practice implications
Techniques
Journal
Skeletal radiology
ISSN: 1432-2161
Titre abrégé: Skeletal Radiol
Pays: Germany
ID NLM: 7701953
Informations de publication
Date de publication:
Jan 2022
Jan 2022
Historique:
received:
20
03
2021
accepted:
26
07
2021
revised:
23
07
2021
pubmed:
17
8
2021
medline:
1
12
2021
entrez:
16
8
2021
Statut:
ppublish
Résumé
Bone marrow aspiration and biopsy (BMAB) is a valuable diagnostic procedure commonly performed for evaluation of a wide spectrum of diseases including hematologic abnormalities, nonhematologic malignancies, metabolic abnormalities, and tumor treatment response such as chemotherapy and bone marrow transplantation, hematologic tumor staging, and suspected infection in patients with fever of unknown origin. This minimally invasive intervention offers excellent safety profile and a high diagnostic yield. Radiologists should be familiar with clinical implications of BMAB for patient care and be able to implement various technical armamentarium available to achieve a safe intervention while maximizing procedure yield.
Identifiants
pubmed: 34398308
doi: 10.1007/s00256-021-03882-w
pii: 10.1007/s00256-021-03882-w
doi:
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
81-88Informations de copyright
© 2021. ISS.
Références
Bain BJ. Bone marrow aspiration. J Clin Pathol. 2001;54:657–63.
doi: 10.1136/jcp.54.9.657
Bain BJ. Bone marrow trephine biopsy. J Clin Pathol. 2001;54:737–42.
doi: 10.1136/jcp.54.10.737
Moid F, DePalma L. Comparison of relative value of bone marrow aspirates and bone marrow trephine biopsies in the diagnosis of solid tumor metastasis and Hodgkin lymphoma: institutional experience and literature review. Arch Pathol Lab Med. 2005;129(4):497.
doi: 10.5858/2005-129-497-CORVOB
Hamid GA, Hanibala N. Comparison of bone marrow aspiration and bone marrow biopsy in neoplastic disease. Gulf J Oncol. 2009;6:41–4.
Joshi R, Horncastle D, Elderfield K, Lampert I, Rahemtulla A, Naresh KN. Bone marrow trephine combined with immunohistochemistry is superior to bone marrow aspirate in follow-up of myeloma patients. J Clin Pathol. 2008;61(2):213–6.
doi: 10.1136/jcp.2007.049130
Lee SH, Erber WN, Porwit A, Tomonaga M, Peterson LC. ICSH guidelines for the standardization of bone marrow specimens and reports. Int J Lab Hematol. 2008;30(5):349–64.
doi: 10.1111/j.1751-553X.2008.01100.x
Kaur M, Singh Rana AP, Kapoor S, Puri A. Diagnostic value of bone marrow aspiration and biopsy in routine hematology practice. J Clin Diagn Res. 2014;8(8):FC13–6.
pubmed: 25302200
pmcid: 4190721
Riley RS, Hogan TF, Pavot DR, et al. Pathologist’s perspective on bone marrow aspiration and biopsy: I. performing a bone marrow examination. J Clin Lab Anal. 2004;18:70–90.
doi: 10.1002/jcla.20008
Jain S, Enzerra M, Mehta RS, Smith R, Djokic M. Bone marrow biopsies performed by both the powered OnControl drill device and the Jamshidi needle produce adequate specimens. J Clin Pathol. 2017;70(6):541–3.
doi: 10.1136/jclinpath-2016-204153
Schnapauff D, Marnitz T, Freyhardt P, et al. CT guided bone biopsy using a battery powered intraosseous device. Cardiovasc Intervent Radiol. 2013;36(5):1405–10.
doi: 10.1007/s00270-013-0617-z
Stensby JD, Long JR, Hillen TJ, Jennings JW. Safety of bone marrow aspiration and biopsy in severely thrombocytopenic patients. Skeletal Radiol. 2020. https://doi.org/10.1007/s00256-020-03623 .
doi: 10.1007/s00256-020-03623
pubmed: 33011873
Long JR, Stensby JD, Wiesner EL, Bryson WN, Hillen TJ, Jennings JW. Efficacy and safety of bone marrow aspiration and biopsy using fluoroscopic guidance and a drill-powered needle: clinical experience from 775 cases. Eur Radiol. 2020;30(11):5964–70.
doi: 10.1007/s00330-020-06987-3
Liu B, Limback J, Kendall M, et al. Safety of CT-guided bone marrow biopsy in thrombocytopenic patients: a retrospective review. J Vasc Interv Radiol. 2017;28(12):1727–31.
doi: 10.1016/j.jvir.2017.08.009
Tomasian A, Hillen TJ, Jennings JW. Bone biopsies: what radiologists need to know. AJR Am J Roentgenol. 2020;215(3):523–33.
doi: 10.2214/AJR.20.22809
Hyun BH, Stevenson AJ, Hanau CA. Fundamentals of bone marrow examination. Hematol Oncol Clin North Am. 1994;8:651–63.
doi: 10.1016/S0889-8588(18)30152-7
Diebold J, Molina T, Camilleri-Broet S, Le Tourneau A, Audouin J. Bone marrow manifestations of infections and systemic diseases observed in bone marrow trephine biopsy review. Histopathology. 2000;37:199–211.
doi: 10.1046/j.1365-2559.2000.00965.x
Kilby JM, Marques MB, Jaye DL, et al. The yield of bone marrow biopsy and culture compared with blood culture in the evaluation of HIV-infected patients for mycobacterial and fungal infections. Am J Med. 1998;104:123–8.
doi: 10.1016/S0002-9343(97)00353-7
Benito N, Nunez A, de Gorgolas M, et al. Bone marrow biopsy in the diagnosis of fever of unknown origin in patients with acquired immunodeficiency syndrome. Arch Intern Med. 1997;157:1577–80.
doi: 10.1001/archinte.1997.00440350085008
Penchansky L. Bone marrow biopsy in the metastatic work-up of solid tumors in children. Cancer. 1984;54:1447–8.
doi: 10.1002/1097-0142(19841001)54:7<1447::AID-CNCR2820540737>3.0.CO;2-8
Pittaluga S, Tierens A, Dodoo YL, Delabie J, De Wolf-Peeters C. How reliable is histologic examination of bone marrow trephine biopsy specimens for the staging of non-Hodgkin lymphoma? A study of hairy cell leukemia and mantle cell lymphoma involvement of the bone marrow trephine specimen by histologic, immunohistochemical, and polymerase chain reaction techniques. Am J Clin Pathol. 1999;111:179–84.
doi: 10.1093/ajcp/111.2.179
Cheung NK. Detecting neuroblastoma using bone marrow aspiration and bone marrow biopsy. J Pediatr Hematol Oncol. 2000;22:86–8.
doi: 10.1097/00043426-200001000-00017
Valdes-Sanchez M, Nava-Ocampo AA, Palacios-Gonzalez RV, et al. Diagnosis of bone marrow metastases in children with solid tumors and lymphomas. Aspiration, or unilateral or bilateral biopsy? Arch Med Res. 2000;31:58–61.
doi: 10.1016/S0188-4409(00)00042-4
Sale GE, Buckner CD. Pathology of bone marrow in transplant recipients. Hematol Oncol Clinics North Amer. 1988;2:735–56.
doi: 10.1016/S0889-8588(18)30593-8
van den Berg H, Kluin PM, Vossen JM. Early reconstitution of haematopoiesis after allogeneic bone marrow transplantation: a prospective histopathological study of bone marrow biopsy specimens. J Clin Pathol. 1990;43:365–9.
doi: 10.1136/jcp.43.5.365
Liso V, Albano F, Pastore D, et al. Bone marrow aspirate on the 14th day of induction treatment as a prognostic tool in de novo adult acute myeloid leukemia. Haematologica. 2000;85:1285–90.
pubmed: 11114136
Islam A. A new sternal puncture needle. J Clin Pathol. 1991;44(8):690–1.
doi: 10.1136/jcp.44.8.690
Douglas DD, Risdall RJ. Bone marrow biopsy technic. Artifact induced by aspiration. Am J Clin Pathol. 1984;82:92–4.
doi: 10.1093/ajcp/82.1.92
Brynes RK, McKenna RW, Sundberg RD. Bone marrow aspiration and trephine biopsy. An approach to a thorough study. Am J Clin Pathol. 1978;70:753–9.
doi: 10.1093/ajcp/70.5.753
Friedlis MF, Centeno CJ. Performing a better bone marrow aspiration. Phys Med Rehabil Clin N Am. 2016;27(4):919–39.
doi: 10.1016/j.pmr.2016.06.009
Forwood KM, Lee E, Crispin PJ. Comparison of the bone marrow trephine sample quality between On Control drill system and the Jamshidi needle. Int J Lab Hematol. 2019;41(3):373–9.
doi: 10.1111/ijlh.12984
Bain BJ. Bone marrow biopsy morbidity and mortality. Br J Heamatol. 2003;121(6):949–51.
doi: 10.1046/j.1365-2141.2003.04329.x
Bain BJ. Morbidity associated with bone marrow aspiration and trephine biopsy - a review of UK data for 2004. Haematologica. 2006;91(9):1293–4.
pubmed: 16956842
Roth JS, Newman EC. Gluteal compartment syndrome and sciatica after bone marrow biopsy: a case report and review of the literature. Am Surg. 2002;68:791–4.
pubmed: 12356152
Chamisa I. Fatal vascular retroperitoneal injury following bone marrow biopsy. S Afr Med J. 2007;97:246.
pubmed: 17446945
Berber I, Erkurt M, Kuku I, et al. An unexpected complication of bone marrow aspiration and trephine biopsy: arteriovenous fistula. Med Princ Pract. 2014;23(4):380–3.
doi: 10.1159/000358173
Khakwani M, Srinath S, Pratt G, Moss P. A rare complication of bone marrow aspiration and trephine biopsy: staphylococcus aureus osteomyelitis and septicaemia. Br J Haematol. 2019;184(1):7.
doi: 10.1111/bjh.15630
Vadlamudi V, Sterling K (2017) Fluoroscopically guided powered bone marrow biopsy in interventional radiology: a safe and efficacious procedure. Poster presented at: 42nd Annual Scientific Meeting of Society of Interventional Radiology; 2017; Washington, DC
Ellis LD, Jensen WN, Westerman MP. Needle biopsy of bone and marrow; an experience with 1,445 biopsies. Arch Intern Med. 1964;114:213–21.
doi: 10.1001/archinte.1964.03860080063005
Swerdlow SH, Campo E, Harris NL, Jaffe ES, Pileri SA, Stein H. World Health Organization classification of tumours of haematopoietic and lymphoid tissues, 4th edn. 2008; International Agency for Research on Cancer, Lyon
Engeset A, Nesheim A, Sokolowski J. Incidence of ‘dry tap’ on bone marrow aspirations in lymphomas and carcinomas. Diagnostic value of the small material in the needle. Scand J Hematol. 1978;22(5):417–22.
doi: 10.1111/j.1600-0609.1979.tb00439.x