Targeting non-pulmonary vein triggers in persistent atrial fibrillation: results from a prospective, multicentre, observational registry.
Catheter ablation
Non-pulmonary vein triggers
Outcomes
Persistent atrial fibrillation
Pulmonary veins
Registry
Journal
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
ISSN: 1532-2092
Titre abrégé: Europace
Pays: England
ID NLM: 100883649
Informations de publication
Date de publication:
07 12 2021
07 12 2021
Historique:
received:
03
08
2020
accepted:
14
06
2021
pubmed:
22
8
2021
medline:
1
4
2022
entrez:
21
8
2021
Statut:
ppublish
Résumé
We evaluated the efficacy of an ablation strategy empirically targeting pulmonary veins (PVs) and posterior wall (PW) and the prevalence and clinical impact of extrapulmonary trigger inducibility and ablation in a large cohort of patients with persistent atrial fibrillation (PerAF). A total of 1803 PerAF patients were prospectively enrolled. All patients underwent pulmonary vein antrum isolation (PVAI) extended to the entire PW. A standardized protocol was performed to confirm persistent PVAI and elicit any triggers originating from non-PV sites. All non-PV triggers initiating sustained atrial tachyarrhythmias were ablated. Ablation of non-PV sites triggering non-sustained runs (<30 s) of atrial tachyarrhythmias or promoting frequent premature atrial complexes (≥10/min) was left to operator's discretion. Overall, 1319 (73.2%) patients had documented triggers from non-PV areas. After 17.4 ± 8.5 months of follow-up, the cumulative freedom from atrial tachyarrhythmias among patients without inducible non-PV triggers (n = 484) was 70.2%. Patients with ablation of induced non-PV triggers had a significantly higher arrhythmia control than those whose triggers were not ablated (67.9% vs. 39.4%, respectively; P < 0.001). After adjusting for clinically relevant variables, patients in whom non-PV triggers were documented but not ablated had an increased risk of arrhythmia relapse (hazard ratio: 2.39; 95% confidence interval: 2.01-2.83; P < 0.001). Pulmonary vein antrum isolation extended to the entire PW might provide acceptable long-term arrhythmia-free survival in PerAF patients without inducible non-PV triggers. In our population of PerAF patients, non-PV triggers could be elicited in ∼70% of PerAF patients and their elimination significantly improved outcomes.
Identifiants
pubmed: 34417816
pii: 6356117
doi: 10.1093/europace/euab161
doi:
Types de publication
Journal Article
Multicenter Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
1939-1949Informations de copyright
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2021. For permissions, please email: journals.permissions@oup.com.