Constrained Active Fault Tolerant Control Based on Active Fault Diagnosis and Interpolation Optimization.
active diagnosis
active reconfiguration
constrained systems
fault tolerance
interpolation control
linear programming
Journal
Entropy (Basel, Switzerland)
ISSN: 1099-4300
Titre abrégé: Entropy (Basel)
Pays: Switzerland
ID NLM: 101243874
Informations de publication
Date de publication:
21 Jul 2021
21 Jul 2021
Historique:
received:
24
06
2021
revised:
14
07
2021
accepted:
15
07
2021
entrez:
27
8
2021
pubmed:
28
8
2021
medline:
28
8
2021
Statut:
epublish
Résumé
A new active fault tolerant control scheme based on active fault diagnosis is proposed to address the component/actuator faults for systems with state and input constraints. Firstly, the active fault diagnosis is composed of diagnostic observers, constant auxiliary signals, and separation hyperplanes, all of which are designed offline. In online applications, only a single diagnostic observer is activated to achieve fault detection and isolation. Compared with the traditional multi-observer parallel diagnosis methods, such a design is beneficial to improve the diagnostic efficiency. Secondly, the active fault tolerant control is composed of outer fault tolerant control, inner fault tolerant control and a linear-programming-based interpolation control algorithm. The inner fault tolerant control is determined offline and satisfies the prescribed optimal control performance requirement. The outer fault tolerant control is used to enlarge the feasible region, and it needs to be determined online together with the interpolation optimization. In online applications, the updated state estimates trigger the adjustment of the interpolation algorithm, which in turn enables control reconfiguration by implicitly optimizing the dynamic convex combination of outer fault tolerant control and inner fault tolerant control. This control scheme contributes to further reducing the computational effort of traditional constrained predictive fault tolerant control methods. In addition, each pair of inner fault tolerant control and diagnostic observer is designed integratedly to suppress the robust interaction influences between estimation error and control error. The soft constraint method is further integrated to handle some cases that lead to constraint violations. The effectiveness of these designs is finally validated by a case study of a wastewater treatment plant model.
Identifiants
pubmed: 34441064
pii: e23080924
doi: 10.3390/e23080924
pmc: PMC8391791
pii:
doi:
Types de publication
Journal Article
Langues
eng
Références
Entropy (Basel). 2020 May 27;22(6):
pubmed: 33286370