FEM based simulation of magnetic drug targeting in a multibranched vessel model.

FEM 3D simulation Magnetic drug targeting Superparamagnetic iron oxide nanoparticles Tumor vessel network

Journal

Computer methods and programs in biomedicine
ISSN: 1872-7565
Titre abrégé: Comput Methods Programs Biomed
Pays: Ireland
ID NLM: 8506513

Informations de publication

Date de publication:
Oct 2021
Historique:
received: 22 03 2021
accepted: 07 08 2021
pubmed: 1 9 2021
medline: 29 9 2021
entrez: 31 8 2021
Statut: ppublish

Résumé

Magnetic drug targeting (MDT) is a promising technology to improve cancer therapy. MDT describes the accumulation of drug loaded superparamagnetic iron oxide nanoparticles (SPIONs) at a desired location, e. g. a tumor, by application of a magnetic field. Here, we evaluate the effectivity of MDT for an endoscopic placement of two different configurations of magnet arrays, i. e. six magnets with same poles facing each other and a Halbach array. Compared to conventional magnet setups outside the body, this endoscopic placement gives the possibility to achieve higher magnetic field gradients inside the tumor. For such a MDT concept, we present FEM based simulations of MDT tracing single SPIONs in a 3D geometry of eight multibranched vessels with sizes in the range of capillaries. In these simulations, the effect of the magnetic field gradient as well as of magnet distance to the vessel geometry, magnetic flux density of the magnets, SPIONs hydrodynamic diameter and magnetic moment on the MDT effectivity is calculated. The blood flow is modelled as an incompressible Newtonian fluid and the SPIONs are suspended in the blood flow. Statistical significance of the targeting effectivity results is tested with the Mann-Whitney-U-Test. The results show that the magnetic targeting effectivity is up to 32 % higher than the one calculated without the presence of a magnetic field. In the investigated vessel network, this effect on the targeting effectivity is dependent on the number of local magnetic field maxima that are approached with a high gradient and is noticeable up to 200 µm distance of the magnet to the vessel geometry. We conclude that for an effective application of MDT, the magnet configuration needs to be placed close to the tumor and should yield a large number of magnetic field maxima that are approached with a high gradient.

Sections du résumé

BACKGROUND AND OBJECTIVE OBJECTIVE
Magnetic drug targeting (MDT) is a promising technology to improve cancer therapy. MDT describes the accumulation of drug loaded superparamagnetic iron oxide nanoparticles (SPIONs) at a desired location, e. g. a tumor, by application of a magnetic field. Here, we evaluate the effectivity of MDT for an endoscopic placement of two different configurations of magnet arrays, i. e. six magnets with same poles facing each other and a Halbach array. Compared to conventional magnet setups outside the body, this endoscopic placement gives the possibility to achieve higher magnetic field gradients inside the tumor.
METHODS METHODS
For such a MDT concept, we present FEM based simulations of MDT tracing single SPIONs in a 3D geometry of eight multibranched vessels with sizes in the range of capillaries. In these simulations, the effect of the magnetic field gradient as well as of magnet distance to the vessel geometry, magnetic flux density of the magnets, SPIONs hydrodynamic diameter and magnetic moment on the MDT effectivity is calculated. The blood flow is modelled as an incompressible Newtonian fluid and the SPIONs are suspended in the blood flow. Statistical significance of the targeting effectivity results is tested with the Mann-Whitney-U-Test.
RESULTS RESULTS
The results show that the magnetic targeting effectivity is up to 32 % higher than the one calculated without the presence of a magnetic field. In the investigated vessel network, this effect on the targeting effectivity is dependent on the number of local magnetic field maxima that are approached with a high gradient and is noticeable up to 200 µm distance of the magnet to the vessel geometry.
CONCLUSIONS CONCLUSIONS
We conclude that for an effective application of MDT, the magnet configuration needs to be placed close to the tumor and should yield a large number of magnetic field maxima that are approached with a high gradient.

Identifiants

pubmed: 34464768
pii: S0169-2607(21)00428-4
doi: 10.1016/j.cmpb.2021.106354
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

106354

Informations de copyright

Copyright © 2021. Published by Elsevier B.V.

Déclaration de conflit d'intérêts

Conflicts of Interest The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

Auteurs

Max C Lindemann (MC)

Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany.

Till Luttke (T)

Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany.

Nadine Nottrodt (N)

Fraunhofer Institute for Laser Technology ILT Aachen, Steinbachstr. 15, 52074 Aachen, Germany.

Thomas Schmitz-Rode (T)

Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany.

Ioana Slabu (I)

Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany. Electronic address: slabu@ame.rwth-aachen.de.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH