Longitudinally centered embossed structure in the locking compression plate for biodegradable bone implant plate: a finite element analysis.


Journal

Computer methods in biomechanics and biomedical engineering
ISSN: 1476-8259
Titre abrégé: Comput Methods Biomech Biomed Engin
Pays: England
ID NLM: 9802899

Informations de publication

Date de publication:
May 2022
Historique:
pubmed: 7 9 2021
medline: 21 4 2022
entrez: 6 9 2021
Statut: ppublish

Résumé

In the current revolution of internal fixation implant in orthopaedics, a biodegradable implant is the most awaited and exceptional medical device where biodegradable material has paid more attention to the success of a biodegradable implant than the design of a biodegradable bone implant plate. By far, LCP is the most traditionally used implant plate (using non-biodegradable material) because of its experimental success, but not with qualified biodegradable material (Mg-alloy). This lack of mechanical performance is a major drawback that can be rectified by better structural design. This will help avoid few other problems as well. Therefore, with proper consideration, the LCP has been added to a semicircular filleted longitudinally centered embossed (LCE) structure to enhance overall mechanical performance that can help emphasize mechanical support even after continuous degradation when applied in a physiological environment. For mechanical verification of this advanced design of biodegradable bone implant plate, four-point bending test (4PBT) and axial compression test (ACT) have been performed using FEM on LCELCP, LCP, continuously degraded (CD)-LCELCP, and CD-LCP. LCELCP showed reduced stress of about 22% and 10% in 4PBT and ACT, respectively, compared to LCP. CD-LCELCP is safe during ACT over 6 months of continuous degradation when the degradation rate is assumed to be 4 mm/year. These results also ensured accuracy using mesh convergence and also mesh checked for quality assurance. Overall, LCELCP can be considered as a biodegradable bone implant plate because of its superior performance, if its ultimate validation is carried out through animal/human trials as future work.

Identifiants

pubmed: 34486894
doi: 10.1080/10255842.2021.1970145
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

603-618

Auteurs

Girish Chandra (G)

Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh, India.

Ajay Pandey (A)

Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh, India.

Nilesh Tipan (N)

Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh, India.

Articles similaires

Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice
Animals Tail Swine Behavior, Animal Animal Husbandry

Classifications MeSH