Yielding quality viral RNA by using two different chemistries: a comparative performance study.


Journal

BioTechniques
ISSN: 1940-9818
Titre abrégé: Biotechniques
Pays: England
ID NLM: 8306785

Informations de publication

Date de publication:
10 2021
Historique:
pubmed: 17 9 2021
medline: 26 10 2021
entrez: 16 9 2021
Statut: ppublish

Résumé

Purity and integrity are two important criteria for any RNA extraction process to qualify the RNA for meaningful gene expression analysis. This study compares four commercially available RNA extraction kits using silica membrane and magnetic bead separation methods. The performance was evaluated in terms of both quantity (total RNA amount in μg/μl) and purity (260/280 ratio). The concentration and purity of each kit was significantly different from those of the others (p < 0.001). Although quantity obtained from Mag MAX is comparatively lower than QIAGEN, the quality is comparable as evident from real-time PCR performance. This study suggests that there are practical differences between these RNA extraction kits that should be taken into account while isolating RNA required for gene expression analysis.

Identifiants

pubmed: 34528832
doi: 10.2144/btn-2021-0054
doi:

Substances chimiques

Membranes, Artificial 0
RNA, Viral 0
Reagent Kits, Diagnostic 0
Silicon Dioxide 7631-86-9

Types de publication

Comparative Study Journal Article Research Support, U.S. Gov't, Non-P.H.S.

Langues

eng

Sous-ensembles de citation

IM

Pagination

510-515

Auteurs

Jyotsnamayee Sabat (J)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Subhra Subhadra (S)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Sonalika Rath (S)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Lal Mohan Ho (LM)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Srikanta Kanungo (S)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Sailendra Panda (S)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Madhab Charan Mandal (MC)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Saroj Dash (S)

PRMMCH, Baripada, Odisha, Pandit Raghunath Murmu Medical College, Baripada, Odisha.

Sanghamitra Pati (S)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Jyotirmayee Turuk (J)

Virus Research & Diagnostic Laboratory, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH