Ratiometric Probe for Rapid Naked Eye Detection of Toxic Hydrazine: Real Time Application in Strip Test, Spray Test and Soil Analysis.


Journal

Journal of fluorescence
ISSN: 1573-4994
Titre abrégé: J Fluoresc
Pays: Netherlands
ID NLM: 9201341

Informations de publication

Date de publication:
Nov 2021
Historique:
received: 29 07 2021
accepted: 08 09 2021
pubmed: 22 9 2021
medline: 4 2 2022
entrez: 21 9 2021
Statut: ppublish

Résumé

Striking colorimetric probe (CynH) for abrupt detection of hydrazine under complete aqueous solution was achieved. The water soluble probe was designed with electron "push-pull" strategy by coupling of 4-hydroxy benzaldehyde and 2, 3, 3-trimethylindolinine. The positively charged N-propylated indolinine make the probe completely soluble in water. The probe yields eye catching selective detection of hydrazine over other competing analytes with high sensitivity. Obvious colour change was observed from colourless to appearance of bright pink colour with hydrazine. It reacts quickly with hydrazine within 2 min and makes the probe an effective candidate for practical application. The real time application was demonstrated using paper strip to detect hydrazine vapour. This probe is superior to earlier reported probes because of its effective sensing of hydrazine displayed with various applications including real-time strip based sensing, spray test and soil analysis. In all the examinations, the probe yields distinct response with rapid naked eye colour change which overcomes the drawbacks of previous reports.

Identifiants

pubmed: 34545433
doi: 10.1007/s10895-021-02825-x
pii: 10.1007/s10895-021-02825-x
doi:

Substances chimiques

Fluorescent Dyes 0
Hydrazines 0
Soil 0
hydrazine 27RFH0GB4R

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1917-1925

Informations de copyright

© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Références

Rosca V, Koper MT (2008) Electrocatalytic oxidation of hydrazine on platinum electrodes in alkaline solutions. Electrochim Acta 53:5199–5205. https://doi.org/10.1016/j.electacta.2008.02.054
doi: 10.1016/j.electacta.2008.02.054
Yu L, Zhang X, Yu L (2014) On-line Determination of Hydrazine in Environmental Water by Reference Flow Injection Analysis. Communications in Information Science and Management Engineering., 4: 13, Book series, 1
Khaled K (2006) Experimental and theoretical study for corrosion inhibition of mild steel in hydrochloric acid solution by some new hydrazine carbodithioic acid derivatives. Appl Surf Sci 252:4120–4128. https://doi.org/10.1016/j.apsusc.2005.06.016
doi: 10.1016/j.apsusc.2005.06.016
Zelnick SD, Mattie DR, Stepaniak PC (2003) Occupational exposure to hydrazines: treatment of acute central nervous system toxicity. Aviat Space Environ Med 74:1285–1291
pubmed: 14692474
Yin WX, Li ZP, Zhu JK, Qin HY (2008) Effects of NaOH addition on performance of the direct hydrazine fuel cell. J Power Sources 182:520–523. https://doi.org/10.1016/j.jpowsour.2008.04.028
doi: 10.1016/j.jpowsour.2008.04.028
Aigner B, Darsow U, Grosber M, Ring J, Plötz S (2010) Multiple basal cell carcinomas after long-term exposure to hydrazine: Case report and review of the literature. Dermatology 221:300–302. https://doi.org/10.1159/000321338
doi: 10.1159/000321338 pubmed: 21099194
Garrod S, Bollard ME, Nicholls AW, Connor SC, Connelly J, Nicholson JK, Holmes E (2005) Integrated metabonomic analysis of the multiorgan effects of hydrazine toxicity in the rat. Chem Res Toxicol 18:115–122. https://doi.org/10.1021/tx0498915
doi: 10.1021/tx0498915 pubmed: 15720114
Umar A, Rahman MM, Kim SH, Hahn YB (2008) Zinc oxide nanonail based chemical sensor for hydrazine detection. Chem Comm 2:66–168. https://doi.org/10.1039/B711215G
doi: 10.1039/B711215G
Cruz Vieira I, Omuro Lupetti K, Fatibello-Filho O (2002) Sweet potato (Ipomoea batatas (L.) Lam.) tissue as a biocatalyst in a paraffin/graphite biosensor for hydrazine determination in boiler feed water. Anal Lett 35:2221–2231. https://doi.org/10.1081/AL-120016097
doi: 10.1081/AL-120016097
Reilly CA, Aust SD (1997) Peroxidase substrates stimulate the oxidation of hydralazine to metabolites which cause single-strand breaks in DNA. Chem Res Toxicol 10:328–334. https://doi.org/10.1021/tx960189l
doi: 10.1021/tx960189l pubmed: 9084913
Leakakos T, Shank RC (1994) Hydrazine genotoxicity in the neonatal rat. Toxicol Appl Pharm 126:295–300. https://doi.org/10.1006/taap.1994.1119
doi: 10.1006/taap.1994.1119
Noda A, Ishizawa M, Ohno K, Sendo T, Noda H (1986) Relationship between oxidative metabolites of hydrazine and hydrazine-induced mutagenicity. Toxicol Lett 31:131–137. https://doi.org/10.1016/0378-4274(86)90006-8
doi: 10.1016/0378-4274(86)90006-8 pubmed: 3520960
Vivekanandan P, Gobianand K, Priya S, Vijayalakshmi P, Karthikeyan S (2007) Protective effect of picroliv against hydrazine-induced hyperlipidemia and hepatic steatosis in rats. Drug Chem Toxicol 30:241–252. https://doi.org/10.1080/01480540701375216
doi: 10.1080/01480540701375216 pubmed: 17613009
Oh JA, Park JH, Shin HS (2013) Sensitive determination of hydrazine in water by gas chromatography–mass spectrometry after derivatization with ortho-phthalaldehyde. Anal Chim Acta 769:79–83. https://doi.org/10.1016/j.aca.2013.01.036
doi: 10.1016/j.aca.2013.01.036 pubmed: 23498124
Liu J, Li Y, Jiang J, Huang X (2010) C@ ZnO nanorod array-based hydrazine electrochemical sensor with improved sensitivity and stability. Dalton Trans 39:8693–8697. https://doi.org/10.1039/C0DT00258E
doi: 10.1039/C0DT00258E pubmed: 20714619
Li Y, Deng C, Yang M (2014) Facilely prepared composites of polyelectrolytes and graphene as the sensing materials for the detection of very low humidity. Sensors Actuat B: Chem 194:51–58. https://doi.org/10.1016/j.snb.2013.12.080
doi: 10.1016/j.snb.2013.12.080
Qian Y, Lin J, Han L, Lin L, Zhu H (2014) A resorufin-based colorimetric and fluorescent probe for live-cell monitoring of hydrazine. Biosens Bioelectron 58:282–286. https://doi.org/10.1016/j.bios.2014.02.059
doi: 10.1016/j.bios.2014.02.059 pubmed: 24662059
Goswami S, Paul S, Manna A (2015) Fast and ratiometric naked eye detection of hydrazine for both solid and vapour phase sensing. New J Chem 39:2300–2305. https://doi.org/10.1039/C4NJ02220C
doi: 10.1039/C4NJ02220C
Batchelor-McAuley C, Banks CE, Simm AO, Jones TG, Compton RG (2006) The electroanalytical detection of hydrazine: a comparison of the use of palladium nanoparticles supported on boron-doped diamond and palladium plated BDD microdisc array. Analyst 131:106–110. https://doi.org/10.1039/B513751A
doi: 10.1039/B513751A pubmed: 16365670
Bhutani H, Singh S, Vir S, Bhutani K, Kumar R, Chakraborti AK, Jindal K (2007) LC and LC-MS study of stress decomposition behaviour of isoniazid and establishment of validated stability-indicating assay method. J Pharmaceut Biomed 43:1213–1220. https://doi.org/10.1016/j.jpba.2006.10.013
doi: 10.1016/j.jpba.2006.10.013
Li K, Xu HR, Yu KK, Hou JT, Yu XQ (2013) A coumarin-based chromogenic and ratiometric probe for hydrazine. Anal Methods 5:2653–2656. https://doi.org/10.1039/C3AY40148K
doi: 10.1039/C3AY40148K
Zhang J, Ning L, Liu J, Wang J, Yu B, Liu X, Yao X, Zhang Z, Zhang H (2015) Naked-eye and near-infrared fluorescence probe for hydrazine and its applications in in vitro and in vivo bioimaging. Anal Chem 87:9101–9107. https://doi.org/10.1021/acs.analchem.5b02527
doi: 10.1021/acs.analchem.5b02527 pubmed: 26274784
Sun M, Bai L, Liu DQ (2009) A generic approach for the determination of trace hydrazine in drug substances using in situ derivatization-headspace GC–MS. J Pharmaceut Biomed 49:529–533. https://doi.org/10.1016/j.jpba.2008.11.009
doi: 10.1016/j.jpba.2008.11.009
Choi MG, Hwang J, Moon JO, Sung J, Chang SK (2011) Hydrazine-selective chromogenic and fluorogenic probe based on levulinated coumarin. Org Lett 13:5260–5263. https://doi.org/10.1021/ol202136q
doi: 10.1021/ol202136q pubmed: 21916492
Zhu S, Lin W, Yuan L (2013) Development of a near-infrared fluorescent probe for monitoring hydrazine in serum and living cells. Anal Methods 5:3450–3453. https://doi.org/10.1039/C3AY40540K
doi: 10.1039/C3AY40540K
Cui L, Peng Z, Ji C, Huang J, Huang D, Ma J, Zhang S, Qian X, Xu Y (2014) Hydrazine detection in the gas state and aqueous solution based on the Gabriel mechanism and its imaging in living cells. Chem Comm 50:1485–1487. https://doi.org/10.1039/C3CC48304E
doi: 10.1039/C3CC48304E pubmed: 24365887
Xiao L, Tu J, Sun S, Pei Z, Pei Y, Pang Y, Xu Y (2014) A fluorescent probe for hydrazine and its in vivo applications. RSC Adv 4:41807–41811. https://doi.org/10.1039/C4RA08101C
doi: 10.1039/C4RA08101C
Fan J, Sun W, Hu M, Cao J, Cheng G, Dong H, Song K, Liu Y, Sun S, Peng X (2012) An ICT-based ratiometric probe for hydrazine and its application in live cells. Chem Comm 48:8117–8119. https://doi.org/10.1039/C2CC34168A
doi: 10.1039/C2CC34168A pubmed: 22766565
Oyefusi A, Olanipekun O, Neelgund GM, Peterson D, Stone JM, Williams E, Carson L, Regisford G, Oki A (2014) Hydroxyapatite grafted carbon nanotubes and graphene nanosheets: Promising bone implant materials. Spectrochim Acta Part A Mol Biomol Spectrosc 132:410–416. https://doi.org/10.1016/j.saa.2014.04.004
doi: 10.1016/j.saa.2014.04.004
Sun M, Guo J, Yang Q, Xiao N, Li Y (2014) A new fluorescent and colorimetric sensor for hydrazine and its application in biological systems. J Mater Chem B 2:1846–1851. https://doi.org/10.1039/C3TB21753A
doi: 10.1039/C3TB21753A pubmed: 32261521
Tse H, Li Q, Chan S, You Q, Lee AW, Chan W (2016) A ratiometric fluorescent and colorimetric probe for selective detection of hydrazine. RSC Adv 6:14678–14681. https://doi.org/10.1039/C5RA26683A
doi: 10.1039/C5RA26683A
Ruan S, Gao Y, Wang Y, Li M, Yang H, Song J, Wang Z, Wang S (2020) A novel berberine-based colorimetric and fluorimetric probe for hydrazine detection. New J Chem 44:15752–15757. https://doi.org/10.1039/D0NJ03599H
doi: 10.1039/D0NJ03599H
Fraga-Corral M, Carpena M, Garcia-Oliveira P, Pereira A, Prieto M, Simal-Gandara J (2020) Analytical metabolomics and applications in health, environmental and food science. Crit Rev Anal Chem 1–23.  https://doi.org/10.1080/10408347.2020.1823811
Mahapatra AK, Maji R, Maiti K, Manna SK, Mondal S, Ali SS, Manna S, Sahoo P, Mandal S, Uddin MR (2015) A BODIPY/pyrene-based chemodosimetric fluorescent chemosensor for selective sensing of hydrazine in the gas and aqueous solution state and its imaging in living cells. RSC Adv 5:58228–58236. https://doi.org/10.1039/C5RA10198K
doi: 10.1039/C5RA10198K
Ju Z, Li D, Zhang D, Li D, Wu C, Xu Z (2017) An ESIPT-based fluorescent probe for hydrazine detection in aqueous solution and its application in living cells. J Fluoresce 27:679–687. https://doi.org/10.1007/s10895-016-1997-7
doi: 10.1007/s10895-016-1997-7
Hao Y, Zhang Y, Ruan K, Chen W, Zhou B, Tan X, Wang Y, Zhao L, Zhang G, Qu P (2017) A naphthalimide-based chemodosimetric probe for ratiometric detection of hydrazine. Sensors Actuat B: Chem 244:417–424. https://doi.org/10.1016/j.snb.2016.12.145
doi: 10.1016/j.snb.2016.12.145
Sun Y, Zhao D, Fan S, Duan L (2015) A 4-hydroxynaphthalimide-derived ratiometric fluorescent probe for hydrazine and its in vivo applications. Sensors Actuat B: Chem 208:512–517. https://doi.org/10.1016/j.snb.2014.11.057
doi: 10.1016/j.snb.2014.11.057
Liu C, Wang F, Xiao T, Chi B, Wu Y, Zhu D, Chen X (2018) The ESIPT fluorescent probes for N2H4 based on benzothiazol and their applications for gas sensing and bioimaging. Sensors Actuat B: Chem 256:55–62. https://doi.org/10.1016/j.snb.2017.09.198
doi: 10.1016/j.snb.2017.09.198
Ran YZ, Xu HR, Li K, Yu KK, Yang J, Yu XQ (2016) Development of a mitochondria-targeted fluorescent probe for hydrazine monitoring in living cells. RSC Adv 6:111016–111019. https://doi.org/10.1039/C6RA24110G
doi: 10.1039/C6RA24110G
Ma J, Fan J, Li H, Yao Q, Xia J, Wang J, Peng X (2017) Probing hydrazine with a near-infrared fluorescent chemodosimeter. Dyes Pigment 138:39–46. https://doi.org/10.1016/j.dyepig.2016.11.026
doi: 10.1016/j.dyepig.2016.11.026

Auteurs

Natarajan Vijay (N)

Organic and Polymer Synthesis Laboratory, Department of Chemistry, National Institute of Technology, Tiruchirappalli, 620 015, India.

Sivan Velmathi (S)

Organic and Polymer Synthesis Laboratory, Department of Chemistry, National Institute of Technology, Tiruchirappalli, 620 015, India. velmathis@nitt.edu.

Articles similaires

Humans Meals Time Factors Female Adult

Vancomycin-associated DRESS demonstrates delay in AST abnormalities.

Ahmed Hussein, Kateri L Schoettinger, Jourdan Hydol-Smith et al.
1.00
Humans Drug Hypersensitivity Syndrome Vancomycin Female Male
Populus Soil Microbiology Soil Microbiota Fungi
Humans Male Female Aged Middle Aged

Classifications MeSH