Automatic wide complex tachycardia differentiation using mathematically synthesized vectorcardiogram signals.
electrocardiogram
supraventricular tachycardia
ventricular tachycardia
wide complex tachycardia
Journal
Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc
ISSN: 1542-474X
Titre abrégé: Ann Noninvasive Electrocardiol
Pays: United States
ID NLM: 9607443
Informations de publication
Date de publication:
01 2022
01 2022
Historique:
received:
01
07
2021
accepted:
21
08
2021
pubmed:
26
9
2021
medline:
28
1
2022
entrez:
25
9
2021
Statut:
ppublish
Résumé
Automated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification. A derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one "all-inclusive" model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance. The VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X-lead QRS amplitude change, Y-lead QRS amplitude change, and Z-lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95). Custom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.
Sections du résumé
BACKGROUND
Automated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification.
METHODS
A derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one "all-inclusive" model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance.
RESULTS
The VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X-lead QRS amplitude change, Y-lead QRS amplitude change, and Z-lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95).
CONCLUSION
Custom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.
Identifiants
pubmed: 34562325
doi: 10.1111/anec.12890
pmc: PMC8739609
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e12890Informations de copyright
© 2021 The Authors. Annals of Noninvasive Electrocardiology published by Wiley Periodicals LLC.
Références
Data Brief. 2020 Apr 21;30:105515
pubmed: 32382594
J Cardiovasc Electrophysiol. 2020 Jan;31(1):185-195
pubmed: 31840870
Heart Rhythm. 2020 Mar;17(3):431-438
pubmed: 31546028
J Electrocardiol. 2017 Sep - Oct;50(5):704-709
pubmed: 28506602
Indian Heart J. 2021 Jan-Feb;73(1):7-13
pubmed: 33714412
Ann Noninvasive Electrocardiol. 2022 Jan;27(1):e12890
pubmed: 34562325
J Am Heart Assoc. 2020 Jun 2;9(11):e016598
pubmed: 32427020
Heart Rhythm. 2010 Jul;7(7):922-6
pubmed: 20215043
J Electrocardiol. 2020 Jul - Aug;61:121-129
pubmed: 32599290
Heart Rhythm. 2008 Jan;5(1):89-98
pubmed: 18180024
Circulation. 1991 May;83(5):1649-59
pubmed: 2022022
J Electrocardiol. 2021 Mar-Apr;65:50-54
pubmed: 33503517
Data Brief. 2019 Apr 17;24:103924
pubmed: 31061863
J Electrocardiol. 2019 May - Jun;54:61-68
pubmed: 30925275