Per-COVID-19: A Benchmark Dataset for COVID-19 Percentage Estimation from CT-Scans.
COVID-19
CT-scans
convolutional neural network
dataset generation
deep learning
Journal
Journal of imaging
ISSN: 2313-433X
Titre abrégé: J Imaging
Pays: Switzerland
ID NLM: 101698819
Informations de publication
Date de publication:
18 Sep 2021
18 Sep 2021
Historique:
received:
13
08
2021
revised:
14
09
2021
accepted:
14
09
2021
entrez:
26
9
2021
pubmed:
27
9
2021
medline:
27
9
2021
Statut:
epublish
Résumé
COVID-19 infection recognition is a very important step in the fight against the COVID-19 pandemic. In fact, many methods have been used to recognize COVID-19 infection including Reverse Transcription Polymerase Chain Reaction (RT-PCR), X-ray scan, and Computed Tomography scan (CT- scan). In addition to the recognition of the COVID-19 infection, CT scans can provide more important information about the evolution of this disease and its severity. With the extensive number of COVID-19 infections, estimating the COVID-19 percentage can help the intensive care to free up the resuscitation beds for the critical cases and follow other protocol for less severity cases. In this paper, we introduce COVID-19 percentage estimation dataset from CT-scans, where the labeling process was accomplished by two expert radiologists. Moreover, we evaluate the performance of three Convolutional Neural Network (CNN) architectures: ResneXt-50, Densenet-161, and Inception-v3. For the three CNN architectures, we use two loss functions: MSE and Dynamic Huber. In addition, two pretrained scenarios are investigated (ImageNet pretrained models and pretrained models using X-ray data). The evaluated approaches achieved promising results on the estimation of COVID-19 infection. Inception-v3 using Dynamic Huber loss function and pretrained models using X-ray data achieved the best performance for slice-level results: 0.9365, 5.10, and 9.25 for Pearson Correlation coefficient (PC), Mean Absolute Error (MAE), and Root Mean Square Error (RMSE), respectively. On the other hand, the same approach achieved 0.9603, 4.01, and 6.79 for PCsubj, MAEsubj, and RMSEsubj, respectively, for subject-level results. These results prove that using CNN architectures can provide accurate and fast solution to estimate the COVID-19 infection percentage for monitoring the evolution of the patient state.
Identifiants
pubmed: 34564115
pii: jimaging7090189
doi: 10.3390/jimaging7090189
pmc: PMC8468956
pii:
doi:
Types de publication
Journal Article
Langues
eng
Références
Sci Rep. 2021 Apr 26;11(1):8992
pubmed: 33903608
Nat Commun. 2021 Jan 27;12(1):634
pubmed: 33504775
Pattern Recognit. 2021 May;113:107828
pubmed: 33495661
IEEE Trans Med Imaging. 2021 Oct;40(10):2808-2819
pubmed: 33760731
IEEE Trans Med Imaging. 2020 Aug;39(8):2615-2625
pubmed: 33156775
Sci Rep. 2020 Nov 11;10(1):19549
pubmed: 33177550
Ann Intern Med. 2020 Aug 18;173(4):262-267
pubmed: 32422057
J Imaging. 2021 Aug 04;7(8):
pubmed: 34460767
Radiology. 2020 Apr;295(1):18
pubmed: 32003646
Med Phys. 2021 Mar;48(3):1197-1210
pubmed: 33354790
Sensors (Basel). 2021 Mar 03;21(5):
pubmed: 33802428
Sensors (Basel). 2021 Mar 22;21(6):
pubmed: 33810066
J Imaging. 2021 Mar 09;7(3):
pubmed: 34460707
Sensors (Basel). 2021 Mar 20;21(6):
pubmed: 33804609
IEEE Trans Med Imaging. 2020 Aug;39(8):2626-2637
pubmed: 32730213
Nat Biomed Eng. 2021 Jun;5(6):509-521
pubmed: 33859385
Comput Biol Med. 2021 Aug;135:104526
pubmed: 34146799
Diagn Interv Imaging. 2020 Jul - Aug;101(7-8):431-437
pubmed: 32571748
Sensors (Basel). 2021 Aug 31;21(17):
pubmed: 34502769