Topological Optimization of Auxetic Coronary Stents Considering Hemodynamics.
auxetic metamaterials
computational fluid dynamics
coronary stents
hemodynamics
topology optimization
Journal
Frontiers in bioengineering and biotechnology
ISSN: 2296-4185
Titre abrégé: Front Bioeng Biotechnol
Pays: Switzerland
ID NLM: 101632513
Informations de publication
Date de publication:
2021
2021
Historique:
received:
22
06
2021
accepted:
27
08
2021
entrez:
30
9
2021
pubmed:
1
10
2021
medline:
1
10
2021
Statut:
epublish
Résumé
This paper is to design a new type of auxetic metamaterial-inspired structural architectures to innovate coronary stents under hemodynamics via a topological optimization method. The new architectures will low the occurrence of stent thrombosis (ST) and in-stent restenosis (ISR) associated with the mechanical factors and the adverse hemodynamics. A multiscale level-set approach with the numerical homogenization method and computational fluid dynamics is applied to implement auxetic microarchitectures and stenting structure. A homogenized effective modified fluid permeability (MFP) is proposed to efficiently connect design variables with motions of blood flow around the stent, and a Darcy-Stokes system is used to describe the coupling behavior of the stent structure and fluid. The optimization is formulated to include three objectives from different scales: MFP and auxetic property in the microscale and stenting stiffness in the macroscale. The design is numerically validated in the commercial software MATLAB and ANSYS, respectively. The simulation results show that the new design can not only supply desired auxetic behavior to benefit the deliverability and reduce incidence of the mechanical failure but also improve wall shear stress distribution to low the induced adverse hemodynamic changes. Hence, the proposed stenting architectures can help improve safety in stent implantation, to facilitate design of new generation of stents.
Identifiants
pubmed: 34589473
doi: 10.3389/fbioe.2021.728914
pii: 728914
pmc: PMC8473832
doi:
Types de publication
Journal Article
Review
Langues
eng
Pagination
728914Informations de copyright
Copyright © 2021 Xue, Saha, Beier, Jepson and Luo.
Déclaration de conflit d'intérêts
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Références
Ann Biomed Eng. 2016 Feb;44(2):357-67
pubmed: 26183960
Ann Biomed Eng. 2016 Feb;44(2):315-29
pubmed: 26178872
Circulation. 2006 Feb 7;113(5):657-63
pubmed: 16461838
Circulation. 2001 Apr 3;103(13):1740-5
pubmed: 11282904
J Biomech Eng. 2012 Jan;134(1):011002
pubmed: 22482657
Eur Heart J. 2019 Nov 1;40(41):3421-3433
pubmed: 31566246
Circulation. 2000 Feb 22;101(7):812-8
pubmed: 10683357
Front Bioeng Biotechnol. 2019 Dec 06;7:366
pubmed: 31867313
Med Biol Eng Comput. 2019 Jan;57(1):15-26
pubmed: 29967933
J Biomech. 2006;39(6):1116-28
pubmed: 16549100
Front Bioeng Biotechnol. 2020 Jul 14;8:736
pubmed: 32766219
Ann Biomed Eng. 2019 Mar;47(3):878-890
pubmed: 30552528
Ann Biomed Eng. 2000 Apr;28(4):386-98
pubmed: 10870895
Arterioscler Thromb Vasc Biol. 1998 May;18(5):677-85
pubmed: 9598824
Biomed Tech (Berl). 2019 May 27;64(3):251-262
pubmed: 29933242
J Biomech. 2021 Aug 26;125:110575
pubmed: 34186293
Am J Physiol Heart Circ Physiol. 2005 May;288(5):H2465-75
pubmed: 15653759
J Biomech. 2008;41(5):1053-61
pubmed: 18215394
Acta Bioeng Biomech. 2020;22(3):169-183
pubmed: 33518735
Circulation. 1995 Jun 15;91(12):2995-3001
pubmed: 7796511