Open-Source Automatic Biomarker Measurement on Slit-Lamp Photography to Estimate Visual Acuity in Microbial Keratitis.


Journal

Translational vision science & technology
ISSN: 2164-2591
Titre abrégé: Transl Vis Sci Technol
Pays: United States
ID NLM: 101595919

Informations de publication

Date de publication:
04 10 2021
Historique:
entrez: 4 10 2021
pubmed: 5 10 2021
medline: 26 10 2021
Statut: ppublish

Résumé

To assess clinical applicability of automatic image analysis in microbial keratitis (MK) by evaluating the relationship between biomarker measurements on slit-lamp photography (SLP) and best-corrected visual acuity (BCVA). Seventy-six patients with MK with SLP images and same-day logarithm of the minimum angle of resolution (logMAR) BCVA were evaluated. MK biomarkers (stromal infiltrate, white blood cell infiltration, corneal edema, hypopyon, epithelial defect) were segmented manually by ophthalmologists and automatically by a novel, open-source, deep learning-based segmentation algorithm. Five measurements (presence, maximum width, total area, proportion of the corneal limbus area affected, centrality) were calculated. Correlations between the measurements and BCVA were calculated. An automatic regression model estimated BCVA from the measurements. Differences in performance between using manual and automatic measurements were evaluated using William's test (for correlation) and the paired-sample t-test (for absolute error). Measurements had high correlations of 0.86 (manual) and 0.84 (automatic) with true BCVA. Estimated BCVA had average (mean ± SD) absolute errors of 0.39 ± 0.27 logMAR (manual, median: 0.30) and 0.35 ± 0.28 logMAR (automatic, median: 0.30) and high correlations of 0.76 (manual) and 0.80 (automatic) with true BCVA. Differences between using manual and automatic measurements were not statistically significant for correlations of measurements with true BCVA (P = .66), absolute errors of estimated BCVA (P = .15), or correlations of estimated BCVA with true BCVA (P = .60). The proposed algorithm measured MK biomarkers as accurately as ophthalmologists. Measurements were highly correlated with and estimative of visual acuity. This study demonstrates the potential of developing fully automatic objective and standardized strategies to aid ophthalmologists in the clinical assessment of MK.

Identifiants

pubmed: 34605877
pii: 2777943
doi: 10.1167/tvst.10.12.2
pmc: PMC8496413
doi:

Substances chimiques

Biomarkers 0

Types de publication

Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

2

Subventions

Organisme : NEI NIH HHS
ID : P30 EY005722
Pays : United States
Organisme : NEI NIH HHS
ID : R01 EY031033
Pays : United States
Organisme : NCATS NIH HHS
ID : UL1 TR002240
Pays : United States

Références

N Engl J Med. 2006 Oct 5;355(14):1419-31
pubmed: 17021318
Eye (Lond). 2002 Sep;16(5):608-18
pubmed: 12194077
Cornea. 2018 Mar;37(3):331-339
pubmed: 29256985
Ophthalmology. 2019 Dec;126(12):1722-1724
pubmed: 31307829
Ophthalmology. 1999 Jun;106(6):1166-70; discussion 1171
pubmed: 10366087
Eye Contact Lens. 2016 Sep;42(5):295-7
pubmed: 26618904
Cornea. 2007 Jan;26(1):16-20
pubmed: 17198008
Ophthalmology. 2006 Apr;113(4):526-30
pubmed: 16581414
Arch Ophthalmol. 1983 Oct;101(10):1545-8
pubmed: 6626005
J Refract Surg. 1997 Jul-Aug;13(4):388-91
pubmed: 9268940
Ophthalmology. 2020 Jun;127(6):793-801
pubmed: 32019699
Annu Int Conf IEEE Eng Med Biol Soc. 2019 Jul;2019:6298-6301
pubmed: 31947282
N Engl J Med. 2011 May 19;364(20):1897-908
pubmed: 21526923
Cornea. 2019 Aug;38(8):933-937
pubmed: 31276456
Clin Exp Ophthalmol. 2012 May-Jun;40(4):369-80
pubmed: 22339936
Malawi Med J. 2012 Sep;24(3):69-71
pubmed: 23638278
Ophthalmology. 2017 Dec;124(12S):S66-S70
pubmed: 29157364
Ophthalmic Epidemiol. 2014 Feb;21(1):24-32
pubmed: 24467559
Lancet Glob Health. 2013 Dec;1(6):e339-49
pubmed: 25104599
Trans Am Ophthalmol Soc. 2009 Dec;107:311-24
pubmed: 20126505
Invest Ophthalmol Vis Sci. 2014 Jun 06;55(7):4206-12
pubmed: 24906863
Ophthalmology. 1996 Jan;103(1):23-8
pubmed: 8628555
Retina. 2011 Sep;31(8):1564-73
pubmed: 21451442
Ophthalmology. 2012 Dec;119(12):2537-48
pubmed: 23084240
Bull World Health Organ. 2001;79(3):214-21
pubmed: 11285665
Indian J Ophthalmol. 2009 Jul-Aug;57(4):273-9
pubmed: 19574694
N Engl J Med. 2006 Oct 5;355(14):1432-44
pubmed: 17021319
J Cataract Refract Surg. 2004 Feb;30(2):374-80
pubmed: 15030827
Ophthalmology. 1995 Dec;102(12):1943-8
pubmed: 9098300
Cornea. 2017 Apr;36(4):419-424
pubmed: 28129296
Lancet. 1991 Sep 14;338(8768):650-3
pubmed: 1679472
Med Care. 2003 May;41(5):582-92
pubmed: 12719681
IEEE J Biomed Health Inform. 2021 Jan;25(1):88-99
pubmed: 32248131
Cornea. 2020 Dec;39(12):1503-1509
pubmed: 32833849
Lancet Glob Health. 2017 Dec;5(12):e1221-e1234
pubmed: 29032195

Auteurs

Jessica Loo (J)

Department of Biomedical Engineering, Duke University, Durham, NC, USA.

Maria A Woodward (MA)

Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA.
Institute for Healthcare Policy and Innovation, University of Michigan, Ann Arbor, MI, USA.

Venkatesh Prajna (V)

Department of Cornea and Refractive Services, Aravind Eye Care System, Madurai, Tamil Nadu, India.

Matthias F Kriegel (MF)

Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA.
Department of Ophthalmology, Augenzentrum am St. Franziskus Hospital Münster, Münster, Germany.

Mercy Pawar (M)

Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA.

Mariam Khan (M)

Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA.

Leslie M Niziol (LM)

Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA.

Sina Farsiu (S)

Department of Biomedical Engineering, Duke University, Durham, NC, USA.
Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH