Image-based shading correction for narrow-FOV truncated pelvic CBCT with deep convolutional neural networks and transfer learning.


Journal

Medical physics
ISSN: 2473-4209
Titre abrégé: Med Phys
Pays: United States
ID NLM: 0425746

Informations de publication

Date de publication:
Nov 2021
Historique:
revised: 29 09 2021
received: 20 04 2020
accepted: 01 10 2021
pubmed: 13 10 2021
medline: 18 11 2021
entrez: 12 10 2021
Statut: ppublish

Résumé

Cone beam computed tomography (CBCT) is a standard solution for in-room image guidance for radiation therapy. It is used to evaluate and compensate for anatomopathological changes between the dose delivery plan and the fraction delivery day. CBCT is a fast and versatile solution, but it suffers from drawbacks like low contrast and requires proper calibration to derive density values. Although these limitations are even more prominent with in-room customized CBCT systems, strategies based on deep learning have shown potential in improving image quality. As such, this article presents a method based on a convolutional neural network and a novel two-step supervised training based on the transfer learning paradigm for shading correction in CBCT volumes with narrow field of view (FOV) acquired with an ad hoc in-room system. We designed a U-Net convolutional neural network, trained on axial slices of corresponding CT/CBCT couples. To improve the generalization capability of the network, we exploited two-stage learning using two distinct data sets. At first, the network weights were trained using synthetic CBCT scans generated from a public data set, and then only the deepest layers of the network were trained again with real-world clinical data to fine-tune the weights. Synthetic data were generated according to real data acquisition parameters. The network takes a single grayscale volume as input and outputs the same volume with corrected shading and improved HU values. Evaluation was carried out with a leave-one-out cross-validation, computed on 18 unique CT/CBCT pairs from six different patients from a real-world dataset. Comparing original CBCT to CT and improved CBCT to CT, we obtained an average improvement of 6 dB on peak signal-to-noise ratio (PSNR), +2% on structural similarity index measure (SSIM). The median interquartile range (IQR) Hounsfield unit (HU) difference between CBCT and CT improved from 161.37 (162.54) HU to 49.41 (66.70) HU. Region of interest (ROI)-based HU difference was narrowed by 75% in the spongy bone (femoral head), 89% in the bladder, 85% for fat, and 83% for muscle. The improvement in contrast-to-noise ratio for these ROIs was about 67%. We demonstrated that shading correction obtaining CT-compatible data from narrow-FOV CBCTs acquired with a customized in-room system is possible. Moreover, the transfer learning approach proved particularly beneficial for such a shading correction approach.

Identifiants

pubmed: 34636429
doi: 10.1002/mp.15282
pmc: PMC9297981
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

7112-7126

Subventions

Organisme : CNAO Foundation (Pavia, Italy)
ID : BAA9CONV01

Informations de copyright

© 2021 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.

Références

Int J Radiat Oncol Biol Phys. 2017 Nov 15;99(4):994-1003
pubmed: 28916139
Med Phys. 2019 Jul;46(7):2969-2977
pubmed: 31055859
Med Phys. 2016 Oct;43(10):5635
pubmed: 27782706
Phys Med Biol. 2019 Jul 11;64(14):145003
pubmed: 31117060
Med Phys. 2000 Jan;27(1):39-46
pubmed: 10659736
Phys Med Biol. 2018 Sep 13;63(18):185012
pubmed: 30113015
Med Phys. 2018 Nov;45(11):e1086-e1095
pubmed: 30421805
Med Phys. 2011 Jul;38(7):4296-311
pubmed: 21859031
Int J Radiat Oncol Biol Phys. 2016 May 1;95(1):549-559
pubmed: 27084664
IEEE Trans Image Process. 2004 Apr;13(4):600-12
pubmed: 15376593
Comput Methods Programs Biomed. 2020 Aug;192:105420
pubmed: 32171151
Cureus. 2018 Apr 29;10(4):e2548
pubmed: 29963342
Med Phys. 2018 Oct;45(10):e908-e922
pubmed: 30168155
J Radiat Res. 2013 Jul;54 Suppl 1:i129-35
pubmed: 23824116
Front Neuroinform. 2014 Feb 20;8:13
pubmed: 24600387
Phys Med Biol. 2020 Jul 13;65(14):145002
pubmed: 32294626
Phys Med. 2020 Jan;69:269-274
pubmed: 31927264
Med Phys. 2015 Mar;42(3):1354-66
pubmed: 25735290
Phys Imaging Radiat Oncol. 2020 May 25;14:24-31
pubmed: 33458310
Br J Radiol. 2020 Mar;93(1107):20190594
pubmed: 31647313
Br J Radiol. 2017 Nov;90(1079):20170266
pubmed: 28830239
Med Phys. 2015 Aug;42(8):4449-59
pubmed: 26233175
Med Phys. 2012 Apr;39(4):1991-2000
pubmed: 22482620
Phys Med Biol. 2016 Aug 7;61(15):5781-802
pubmed: 27405692
Med Phys. 1982 Jul-Aug;9(4):464-72
pubmed: 7110075
J Big Data. 2021;8(1):101
pubmed: 34306963
Acta Oncol. 2015;54(9):1651-7
pubmed: 26198654
Med Phys. 2019 Jan;46(1):238-249
pubmed: 30390295
Phys Med. 2015 Feb;31(1):9-15
pubmed: 25455440
Phys Med Biol. 2019 Jan 24;64(3):035011
pubmed: 30523998
Med Phys. 2018 Nov;45(11):4916-4926
pubmed: 30199101
Med Phys. 2021 Nov;48(11):7112-7126
pubmed: 34636429
Med Phys. 2011 Sep;38(9):5186-99
pubmed: 21978063
Phys Med Biol. 2010 Aug 21;55(16):4495-507
pubmed: 20668342
Phys Med Biol. 2019 Jun 10;64(12):125002
pubmed: 31108465
Med Phys. 2010 Oct;37(10):5395-406
pubmed: 21089775
Med Phys. 2018 Jun 11;:
pubmed: 29888791
Int J Radiat Oncol Biol Phys. 2012 Nov 1;84(3):e427-33
pubmed: 22672753

Auteurs

Matteo Rossi (M)

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.

Gabriele Belotti (G)

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.

Chiara Paganelli (C)

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.

Andrea Pella (A)

Bioengineering Unit, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy.

Amelia Barcellini (A)

Radiation Oncology Unit, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy.

Pietro Cerveri (P)

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.

Guido Baroni (G)

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
Bioengineering Unit, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH