Comparative effectiveness of different localization techniques for non-palpable breast cancer. A systematic review and network meta-analysis.
Breast Neoplasms
/ surgery
Comparative Effectiveness Research
Female
Humans
Indocyanine Green
Magnetic Resonance Imaging
Margins of Excision
Mastectomy, Segmental
/ methods
Methylene Blue
Network Meta-Analysis
Operative Time
Radiopharmaceuticals
Reoperation
Surgery, Computer-Assisted
/ methods
Ultrasonography
Breast localization techniques
Non palpable breast cancer
Ultrasound guided surgery
Journal
European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology
ISSN: 1532-2157
Titre abrégé: Eur J Surg Oncol
Pays: England
ID NLM: 8504356
Informations de publication
Date de publication:
Jan 2022
Jan 2022
Historique:
received:
31
08
2021
revised:
25
09
2021
accepted:
01
10
2021
pubmed:
18
10
2021
medline:
22
2
2022
entrez:
17
10
2021
Statut:
ppublish
Résumé
Several localization techniques are in use for localization of non palpable breast cancer but data on comparative effectiveness of these techniques are sparse. Our aim was to provide the first comparative effectiveness data on the topic. PubMed, Ovid, Scopus and Cochrane library were searched for randomized controlled trials. Pairwise meta-analysis was performed when more than 2 studies reported on the same head-to-head comparison. Network meta-analysis was performed in Stata. Eighteen studies with 3112 patients were identified. A star shaped network was formed for every outcome as all studies had as common comparator the wire localization technique (WGL). Ultrasound guided surgery (UGS) had decreased positive margin both in the pairwise [OR = 0.19(0.11, 0.35); P < 0.01] and network meta-analysis OR = 0.19 (0.11,0.60). There was also a statistically significant reduction in re-operation rate [OR = 0.19 (0.11, 0.36); P < 0.01] and operative time [MD = -4.24(-7.85,-0.63); P = 0.02] as compared to WGL in pairwise meta-analysis. Re-operation rate and operative time did not hold there statistical significance in network meta-analysis. On network meta-analysis UGS had a statistically significant reduction in positive margin as compared to radio-guided occult lesion localization (ROLL) OR = 0.19 (0.11,0.6) and radioactive seed localization (RSL) OR = 0.26(0.13, 0.52). UGS had a 54.6% of being the best technique for positive margin. All techniques were equivalent for successful excision, localization complications, operative time and overall complications. UGS has potential benefits in reduction of positive surgical margin, the rest of the techniques seem to have equivalent efficacy. Further randomized trials are required to verify these results.
Sections du résumé
BACKGROUND
BACKGROUND
Several localization techniques are in use for localization of non palpable breast cancer but data on comparative effectiveness of these techniques are sparse. Our aim was to provide the first comparative effectiveness data on the topic.
METHODS
METHODS
PubMed, Ovid, Scopus and Cochrane library were searched for randomized controlled trials. Pairwise meta-analysis was performed when more than 2 studies reported on the same head-to-head comparison. Network meta-analysis was performed in Stata.
RESULTS
RESULTS
Eighteen studies with 3112 patients were identified. A star shaped network was formed for every outcome as all studies had as common comparator the wire localization technique (WGL). Ultrasound guided surgery (UGS) had decreased positive margin both in the pairwise [OR = 0.19(0.11, 0.35); P < 0.01] and network meta-analysis OR = 0.19 (0.11,0.60). There was also a statistically significant reduction in re-operation rate [OR = 0.19 (0.11, 0.36); P < 0.01] and operative time [MD = -4.24(-7.85,-0.63); P = 0.02] as compared to WGL in pairwise meta-analysis. Re-operation rate and operative time did not hold there statistical significance in network meta-analysis. On network meta-analysis UGS had a statistically significant reduction in positive margin as compared to radio-guided occult lesion localization (ROLL) OR = 0.19 (0.11,0.6) and radioactive seed localization (RSL) OR = 0.26(0.13, 0.52). UGS had a 54.6% of being the best technique for positive margin. All techniques were equivalent for successful excision, localization complications, operative time and overall complications.
CONCLUSIONS
CONCLUSIONS
UGS has potential benefits in reduction of positive surgical margin, the rest of the techniques seem to have equivalent efficacy. Further randomized trials are required to verify these results.
Identifiants
pubmed: 34656392
pii: S0748-7983(21)00751-4
doi: 10.1016/j.ejso.2021.10.001
pii:
doi:
Substances chimiques
Radiopharmaceuticals
0
Indocyanine Green
IX6J1063HV
Methylene Blue
T42P99266K
Types de publication
Comparative Study
Journal Article
Meta-Analysis
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
53-59Informations de copyright
Copyright © 2021. Published by Elsevier Ltd.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.