Relining of infrarenal stent-graft with preloaded modified Gore Excluder for occult endoleak with sac expansion.

Cannulation Contralateral gate Endovascular aortic repair Infrarenal abdominal aortic aneurysm Metal artifact Occult endoleak

Journal

Journal of vascular surgery cases and innovative techniques
ISSN: 2468-4287
Titre abrégé: J Vasc Surg Cases Innov Tech
Pays: United States
ID NLM: 101701125

Informations de publication

Date de publication:
Dec 2021
Historique:
received: 01 04 2021
accepted: 10 07 2021
entrez: 25 10 2021
pubmed: 26 10 2021
medline: 26 10 2021
Statut: epublish

Résumé

Endoleaks remain one of the most common indications for reintervention after endovascular aortic repair. Occasionally, aneurysm sac expansion will occur in the absence of a visible endoleak or due to endotension. We describe a case of continued sac expansion without an identifiable endoleak after endovascular aortic repair. Technical challenges during the case included a short distance from the renal arteries to the flow divider and a significant metal artifact. These challenges were addressed by shortening the gate of a Gore Excluder (W.L. Gore & Associates, Flagstaff, Ariz) to the desired length. The contralateral gate was preloaded to allow for use of the snare-ride technique for gate cannulation and overcome the metal artifact that was hindering visualization.

Identifiants

pubmed: 34693100
doi: 10.1016/j.jvscit.2021.07.007
pii: S2468-4287(21)00136-2
pmc: PMC8515168
doi:

Types de publication

Case Reports

Langues

eng

Pagination

669-674

Informations de copyright

© 2021 Published by Elsevier Inc. on behalf of Society for Vascular Surgery.

Références

Eur J Vasc Endovasc Surg. 2018 Dec;56(6):794-807
pubmed: 30104089
CVIR Endovasc. 2019 Oct 27;2(1):34
pubmed: 32026021
Ann Vasc Surg. 2020 Aug;67:223-231
pubmed: 32173471
J Vasc Surg Cases Innov Tech. 2020 Nov 28;7(1):84-88
pubmed: 33665538
Semin Interv Cardiol. 2000 Mar;5(1):35-46
pubmed: 10875222
J Vasc Surg. 2017 Oct;66(4):1285-1289
pubmed: 28705593
J Vasc Surg. 2002 Mar;35(3):461-73
pubmed: 11877693
Eur J Vasc Endovasc Surg. 2019 Oct;58(4):511
pubmed: 31405727
J Endovasc Ther. 2017 Aug;24(4):556-558
pubmed: 28514896
Ann Vasc Surg. 2016 Feb;31:229-38
pubmed: 26627324
J Vasc Surg. 2016 Sep;64(3):600-4
pubmed: 27565586
Invest Radiol. 2010 Sep;45(9):548-53
pubmed: 20644485
J Vasc Surg. 2012 Aug;56(2):538-41
pubmed: 22703976

Auteurs

Aleem K Mirza (AK)

Division of Vascular and Endovascular Surgery, Minneapolis Heart Institute at Abbott Northwestern Hospital, Minneapolis, Minn.

Nedaa Skeik (N)

Division of Vascular and Endovascular Surgery, Minneapolis Heart Institute at Abbott Northwestern Hospital, Minneapolis, Minn.

Jesse Manunga (J)

Division of Vascular and Endovascular Surgery, Minneapolis Heart Institute at Abbott Northwestern Hospital, Minneapolis, Minn.

Classifications MeSH