A multi-measure approach for assessing the performance of fMRI preprocessing strategies in resting-state functional connectivity.
FIX
Motion biases
Noise correction techniques
Physiological noise
aCompCor
fMRI artifacts
Journal
Magnetic resonance imaging
ISSN: 1873-5894
Titre abrégé: Magn Reson Imaging
Pays: Netherlands
ID NLM: 8214883
Informations de publication
Date de publication:
01 2022
01 2022
Historique:
received:
18
03
2021
revised:
17
09
2021
accepted:
17
10
2021
pubmed:
30
10
2021
medline:
22
3
2022
entrez:
29
10
2021
Statut:
ppublish
Résumé
It is well established that head motion and physiological processes (e.g. cardiac and breathing activity) should be taken into consideration when analyzing and interpreting results in fMRI studies. However, even though recent studies aimed to evaluate the performance of different preprocessing pipelines there is still no consensus on the optimal strategy. This is partly due to the fact that the quality control (QC) metrics used to evaluate differences in performance across pipelines have often yielded contradictory results. Furthermore, preprocessing techniques based on physiological recordings or data decomposition techniques (e.g. aCompCor) have not been comprehensively examined. Here, to address the aforementioned issues, we propose a framework that summarizes the scores from eight previously proposed and novel QC metrics to a reduced set of two QC metrics that reflect the signal-to-noise ratio and the reduction in motion artifacts and biases in the preprocessed fMRI data. Using this framework, we evaluate the performance of three commonly used practices on the quality of data: 1) Removal of nuisance regressors from fMRI data, 2) discarding motion-contaminated volumes (i.e., scrubbing) before regression, and 3) low-pass filtering the data and the nuisance regressors before their removal. Using resting-state fMRI data from the Human Connectome Project, we show that the scores of the examined QC metrics improve the most when the global signal (GS) and about 17% of principal components from white matter (WM) are removed from the data. Finally, we observe a small further improvement with low-pass filtering at 0.20 Hz and milder variants of WM denoising, but not with scrubbing.
Identifiants
pubmed: 34715292
pii: S0730-725X(21)00195-8
doi: 10.1016/j.mri.2021.10.028
pii:
doi:
Types de publication
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
228-250Informations de copyright
Copyright © 2021 Elsevier Inc. All rights reserved.