Lower Extremity Splinting: A Head-to-Head Comparison of A Novel One-Step Spray-on Splint Versus Standard Splinting.


Journal

Military medicine
ISSN: 1930-613X
Titre abrégé: Mil Med
Pays: England
ID NLM: 2984771R

Informations de publication

Date de publication:
04 Dec 2021
Historique:
received: 30 08 2021
revised: 25 10 2021
accepted: 23 11 2021
entrez: 5 12 2021
pubmed: 6 12 2021
medline: 6 12 2021
Statut: aheadofprint

Résumé

Splinting is an essential component of treating many lower extremity musculoskeletal injuries; however, little development has been made in splinting technology. The purpose of this study is to evaluate the efficacy of current immobilization equipment for lower extremity fractures by testing a novel one-step spray-on foam splint (Fast Cast) against structural aluminum malleable (SAM) lower extremity musculoskeletal injuries and 6-inch ACE (3M Corp., Minneapolis, MN, USA) bandage splints. Six orthopedic surgical residents and two medical students participated in a prospective analysis of austere splinting techniques and equipment that utilized a cadaveric model with a distal third tibia-fibula shaft fracture. Each participant was observed and scored by three fellowship trained attending orthopedic surgeons. All scoring was independent using a 5-point Likert scale based on 10 splinting criteria (50 total points possible), including quality of radiographic reduction, time to completion, safety, and sustain longitudinal traction. The Likert scale is a set of questions that reflects the respondent's degree of agreement or disagreement with a statement. Each of the 10 questions has a range of 1-5. A score of 50 means the splint performed perfectly. The lowest possible score is a 10. The participants utilized standard equipment that included SAM splints and 6-inch ACE wraps (3M Corp., Minneapolis, MN, USA) in their first attempt. A second immobilization attempt was done with a one-step spray-on foam splint (Fast Cast). After each splinting attempt, the reduction was verified with radiographic imaging. Data analysis was performed using standard descriptive statistics, Student's t-tests, and inter-rater reliability was calculated using Cronbach's alpha scores. This project is Institutional Review Board (IRB) exempt. The one-step spray-on foam splinting technique was superior (P < .05) in all parameters of the Likert scale, yielding a mean overall score of 45.1 points (±3.8), safety 4.7 points, longitudinal traction 4.5 points, and time 136 seconds (±23). The SAM resulted in a mean overall score of 33.8 points (±7.3), safety 2.8 points, longitudinal traction 4.1 points, and time 170 seconds (±52). Radiographic rating was 4.1 points (±0.7) for the SAM splint and 4.5 (±0.6) for Fast Cast. The differences in time to completion and radiograph rating did not reach statistical significance (P = .12 and P = .07, respectively). A one-step spray-on foam splinting technique demonstrated consistent superiority in reducing fracture motion, potential soft-tissue damage, and sustained longitudinal traction as compared to the standard technique.

Identifiants

pubmed: 34865117
pii: 6449326
doi: 10.1093/milmed/usab505
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© The Association of Military Surgeons of the United States 2021. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Auteurs

Tyler Webb (T)

The Ohio State University College of Medicine, Columbus, OH 43210, USA.

Daniel Lynch (D)

The Ohio State University College of Medicine, Columbus, OH 43210, USA.

James Lin (J)

Department of Orthopaedic Surgery, The Ohio State University, Columbus, OH 43202, USA.

Adam Groth (A)

Department of Orthopaedic Surgery, The Ohio State University, Columbus, OH 43202, USA.

Thuan Ly (T)

Division of Orthopaedic Trauma, Massachusetts General Hospital, Boston, MA 02114, USA.

Kevin D Martin (KD)

Department of Orthopaedic Surgery, The Ohio State University, Columbus, OH 43202, USA.

Classifications MeSH