[Abnormally short frenulum induced by circumcision with the disposable circumcision suture device: Causes and improvement of the surgical method].


Journal

Zhonghua nan ke xue = National journal of andrology
ISSN: 1009-3591
Titre abrégé: Zhonghua Nan Ke Xue
Pays: China
ID NLM: 101093592

Informations de publication

Date de publication:
Dec 2020
Historique:
entrez: 13 12 2021
pubmed: 14 12 2021
medline: 15 12 2021
Statut: ppublish

Résumé

To investigate the causes of abnormally short frenulum induced by circumcision with disposable circumcision suture device and the improvement of the surgical method. We retrospectively analyzed the clinical data on 320 cases of phimosis or redundant prepuce treated from January 2020 to September 2020, including 160 children (group A) and 160 adults (group B), each further divided into an observation group (n = 80, groups A1 and B1) and a control group (n = 80, groups A2 and B2). The patients in groups A1 and B1 underwent circumcision by suture positioning at the frenulum with the disposable circumcision suture device, and those in groups A2 and B2 received conventional circumcision with the disposable circumcision suture device. We compared the operation time, incidence rate of abnormally short frenulum and Visual Analogue Scale (VAS) score at 6 hours after surgery among the four groups of patients. Statistically significant differences were observed between groups A1 and A2 in the operation time (12.00 [11.00, 13.00] vs 8.50 [8.50, 9.00] min, P < 0.05) and the incidence rate of abnormally short frenulum (0 vs 10%, P < 0.05) but not in the VAS score (3.00 [3.00, 4.00] vs 3.00 [3.00, 3.75], P > 0.05). Statistically significant differences were also found between groups B1 and B2 in the operation time (12.00 [11.00, 12.00] vs 6.25 [6.00, 7.00] min, P < 0.05) and the incidence rate of abnormally short frenulum (0 vs 7.5%, P < 0.05) but not in the VAS score (2.00 [2.00, 3.00] vs 2.00 [2.00, 3.00], P > 0.05). Abnormally short frenulum induced by circumcision with the disposable circumcision suture device is mainly attributed to ligation and fixation of the prepuce with the fixation band. Circumcision with the disposable circumcision suture device by suture positioning at the frenulum is a safe and effective method worthy of clinical promotion.

Identifiants

pubmed: 34898084

Types de publication

Journal Article

Langues

chi

Sous-ensembles de citation

IM

Pagination

1096-1110

Auteurs

Min-Qiang Shen (MQ)

Department of Urology, Huzhou Central Hospital, Huzhou, Zhejiang 313000, China.
Department of Urology, Central Hospital of Huzhou Normal College, Huzhou, Zhejiang 313000, China.

Tian-Li Shi (TL)

Department of Urology, Huzhou Central Hospital, Huzhou, Zhejiang 313000, China.
Department of Urology, Central Hospital of Huzhou Normal College, Huzhou, Zhejiang 313000, China.

Rong-Hua Yang (RH)

Department of Urology, Huzhou Central Hospital, Huzhou, Zhejiang 313000, China.
Department of Urology, Central Hospital of Huzhou Normal College, Huzhou, Zhejiang 313000, China.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH