Stability of 1-unit/mL insulin aspart solution in cyclic olefin copolymer vials and polypropylene syringes.
drug stability
insulin aspart
intravenous administration
stability-indicating method
Journal
American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists
ISSN: 1535-2900
Titre abrégé: Am J Health Syst Pharm
Pays: England
ID NLM: 9503023
Informations de publication
Date de publication:
01 04 2022
01 04 2022
Historique:
pubmed:
1
1
2022
medline:
6
4
2022
entrez:
31
12
2021
Statut:
ppublish
Résumé
This study evaluated the stability of diluted insulin aspart solutions (containing insulin aspart and preservatives) at their most commonly used concentration in intensive care units (1 unit/mL), in 2 container types: cyclic olefin copolymer (COC) vials and polypropylene (PP) syringes. Insulin aspart solution (1 unit/mL, diluted in 0.9% sodium chloride injection) was stored for 365 days in COC vials with gray stoppers and PP syringes at refrigerated (5°C ± 3°C) and ambient temperatures (25°C ± 2°C at 60% ± 5% relative humidity and protected from light). Chemical testing was conducted monthly using a validated high-performance liquid chromatography method (quantification of insulin aspart, phenol, and metacresol). Physical stability was evaluated monthly via pH measurements, visible and subvisible particle counts, and osmolality measurements. Sterility testing was also performed to validate the sterile preparation process and the maintenance of sterility throughout the study. The limit of stability was set at 90% of the initial concentrations of insulin aspart, phenol, and metacresol. The physicochemical stability of 1-unit/mL insulin solutions stored refrigerated and protected from light, was unchanged in COC vials for the 365-day period and for 1 month in PP syringes. At ambient temperature, subvisible particulate contamination as well as the chemical stability of insulin and metacresol were acceptable for only 1 month's storage in PP syringes, while insulin chemical stability was maintained for only 3 months' storage in COC vials. According to our results, it is not recommended to administer 1-unit/mL pharmacy-diluted insulin solutions after 3 months' storage in COC vials at ambient temperature or after 1 month in PP syringes at ambient temperature. The findings support storage of 1-unit/mL insulin aspart solution in COC vials at refrigerated temperature as the best option over the long term. Sterility was maintained in every condition. Both sterility and physicochemical stability are essential to authorize the administration of a parenteral insulin solution.
Identifiants
pubmed: 34971359
pii: 6490992
doi: 10.1093/ajhp/zxab484
doi:
Substances chimiques
Cycloparaffins
0
Polypropylenes
0
Insulin Aspart
D933668QVX
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
665-675Informations de copyright
© American Society of Health-System Pharmacists 2021. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.