Infrared Thermography Images Acquisition for a Technical Perspective in Screening and Diagnostic Processes: Protocol Standardized Acquisition.

physiotherapy sars-cov-2 temperature thermal imaging camera thermography

Journal

Cureus
ISSN: 2168-8184
Titre abrégé: Cureus
Pays: United States
ID NLM: 101596737

Informations de publication

Date de publication:
Nov 2021
Historique:
accepted: 27 11 2021
entrez: 3 1 2022
pubmed: 4 1 2022
medline: 4 1 2022
Statut: epublish

Résumé

In this technical report we describe the thermographic setting protocol suitable for the FLIR T650SC thermal imager (FLIR Systems, Inc., Wilsonville, OR), an instrument that detects electromagnetic radiation in the infrared field which is physiologically emitted from the human body. FLIR T650SC thermal imager processes infrared radiations graphically and analyzes them through a specific software. In biomedicine, infrared thermography is a promising technique amongst other conventional methods used for detecting skin temperature differences considered as a possible sign of disturbances in the human body. Currently, automatic screening of temperature from a safe distance is an instrument utilized in the front line of the SARS CoV2 emergency. The processing method of the thermogram considers an initial setting of constant parameters that cannot be subsequently modified such as temperature range, focusing and image composition. After the acquisition variable values important in the processing and analysis of the thermogram, such as detection of environment temperature, reflected temperature, emissivity, relative humidity and contrast palette, are set in the software. The analysis is performed using the FLIR Tools software. In the biomedical field standardized acquisition of thermograms facilitates the identification of trigger points and areas of hyper- and hypothermia distributed on the skin surface and muscle bundles. The protocol made it possible to create images with the same acquisition method for all patients. The thermal imaging camera is a valid screening tool because its execution is rapid, it is non-invasive, well-tolerated, and at a low cost for patients.

Identifiants

pubmed: 34976527
doi: 10.7759/cureus.19931
pmc: PMC8712241
doi:

Types de publication

Journal Article

Langues

eng

Pagination

e19931

Informations de copyright

Copyright © 2021, Politi et al.

Déclaration de conflit d'intérêts

The authors have declared that no competing interests exist.

Références

Allergol Int. 2019 Apr;68(2):254-258
pubmed: 30598404
BMC Bioinformatics. 2020 Mar 11;21(Suppl 2):88
pubmed: 32164529
IEEE Trans Med Imaging. 1998 Dec;17(6):1019-27
pubmed: 10048859
Sensors (Basel). 2017 May 05;17(5):
pubmed: 28475155
Infrared Phys Technol. 2012 Jul;55(4):221-235
pubmed: 32288544
J Bodyw Mov Ther. 2019 Jul;23(3):583-587
pubmed: 31563374
Int J Occup Saf Ergon. 2018 Sep;24(3):457-463
pubmed: 28609182
Ann Rheum Dis. 1978 Feb;37(1):48-52
pubmed: 629603
Acta Odontol Scand. 1988 Feb;46(1):41-8
pubmed: 3164162
Complement Ther Med. 2018 Aug;39:19-23
pubmed: 30012388

Auteurs

Stefano Politi (S)

Aerospace Medicine, Diagnostic Therapeutic and Rehabilitative Aeromedical Center, Italian Air Force, Rome, ITA.

Anna Aloisi (A)

Aerospace Medicine, Diagnostic Therapeutic and Rehabilitative Aeromedical Center, Italian Air Force, Rome, ITA.

Vittorio Bartoli (V)

Aerospace Medicine, Diagnostic Therapeutic and Rehabilitative Aeromedical Center, Italian Air Force, Rome, ITA.

Antonio Guglietta (A)

Physiotherapy, Motion Rehab, Itri, ITA.

Fabrizio Magnifica (F)

Neurology, Sapienza University, Rome, ITA.
Aerospace Medicine, Diagnostic Therapeutic and Rehabilitative Aeromedical Center, Italian Air Force, Rome, ITA.

Classifications MeSH