Meta-analysis: Architectural distortion and breast MRI.


Journal

Breast disease
ISSN: 1558-1551
Titre abrégé: Breast Dis
Pays: Netherlands
ID NLM: 8801277

Informations de publication

Date de publication:
2022
Historique:
entrez: 31 1 2022
pubmed: 1 2 2022
medline: 9 3 2022
Statut: ppublish

Résumé

The implementation of digital breast tomosynthesis has increased the detection of architectural distortion (AD). Managing this finding may be experienced as a clinical dilemma in daily practice. Breast Contrast-Enhanced MRI (CE-BMR) is a known modality in case of problem-solving tool for mammographic abnormalities. However, the data about AR and CE-BMR are scant. The purpose was to estimate the benefit of CE-BMR in the setting of architectural distortion detected mammographically through a systematic review and meta-analysis of the literature. A search of MEDLINE and EMBASE databases were conducted in 2020. Based on the PRISMA guidelines, an analysis was performed using the chi-square test of independence to determine if there was a significant association between the result of the test (positive or negative) and the participant condition (malignant or non-malignant). Four studies were available. The negative predictive value (NPV) was 98.3% to 100%. The result of the chi-square indicated that there was significant association between the participant test result and the participant condition for the included publications (X(1,175)2= 84.051, p = 0.0001). The high NPV could allow for deferral of a biopsy in favor of a short-interval imaging follow-up in the setting of a negative CE-BMR.

Sections du résumé

BACKGROUND BACKGROUND
The implementation of digital breast tomosynthesis has increased the detection of architectural distortion (AD). Managing this finding may be experienced as a clinical dilemma in daily practice. Breast Contrast-Enhanced MRI (CE-BMR) is a known modality in case of problem-solving tool for mammographic abnormalities. However, the data about AR and CE-BMR are scant.
OBJECTIVE OBJECTIVE
The purpose was to estimate the benefit of CE-BMR in the setting of architectural distortion detected mammographically through a systematic review and meta-analysis of the literature.
METHODS METHODS
A search of MEDLINE and EMBASE databases were conducted in 2020. Based on the PRISMA guidelines, an analysis was performed using the chi-square test of independence to determine if there was a significant association between the result of the test (positive or negative) and the participant condition (malignant or non-malignant).
RESULTS RESULTS
Four studies were available. The negative predictive value (NPV) was 98.3% to 100%. The result of the chi-square indicated that there was significant association between the participant test result and the participant condition for the included publications (X(1,175)2= 84.051, p = 0.0001).
CONCLUSIONS CONCLUSIONS
The high NPV could allow for deferral of a biopsy in favor of a short-interval imaging follow-up in the setting of a negative CE-BMR.

Identifiants

pubmed: 35094984
pii: BD210045
doi: 10.3233/BD-210045
doi:

Substances chimiques

Contrast Media 0

Types de publication

Journal Article Meta-Analysis Systematic Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

205-214

Auteurs

Romuald Ferre (R)

Radiology Department, La Sarre Hospital, QC, Canada.

Cherie M Kuzmiak (CM)

Department of Radiology, UNC School of Medicine, Chapel Hill, NC, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH