Meta-analysis: Architectural distortion and breast MRI.
Breast
MRI
architectural distortion
mammogram
tomosynthesis
Journal
Breast disease
ISSN: 1558-1551
Titre abrégé: Breast Dis
Pays: Netherlands
ID NLM: 8801277
Informations de publication
Date de publication:
2022
2022
Historique:
entrez:
31
1
2022
pubmed:
1
2
2022
medline:
9
3
2022
Statut:
ppublish
Résumé
The implementation of digital breast tomosynthesis has increased the detection of architectural distortion (AD). Managing this finding may be experienced as a clinical dilemma in daily practice. Breast Contrast-Enhanced MRI (CE-BMR) is a known modality in case of problem-solving tool for mammographic abnormalities. However, the data about AR and CE-BMR are scant. The purpose was to estimate the benefit of CE-BMR in the setting of architectural distortion detected mammographically through a systematic review and meta-analysis of the literature. A search of MEDLINE and EMBASE databases were conducted in 2020. Based on the PRISMA guidelines, an analysis was performed using the chi-square test of independence to determine if there was a significant association between the result of the test (positive or negative) and the participant condition (malignant or non-malignant). Four studies were available. The negative predictive value (NPV) was 98.3% to 100%. The result of the chi-square indicated that there was significant association between the participant test result and the participant condition for the included publications (X(1,175)2= 84.051, p = 0.0001). The high NPV could allow for deferral of a biopsy in favor of a short-interval imaging follow-up in the setting of a negative CE-BMR.
Sections du résumé
BACKGROUND
BACKGROUND
The implementation of digital breast tomosynthesis has increased the detection of architectural distortion (AD). Managing this finding may be experienced as a clinical dilemma in daily practice. Breast Contrast-Enhanced MRI (CE-BMR) is a known modality in case of problem-solving tool for mammographic abnormalities. However, the data about AR and CE-BMR are scant.
OBJECTIVE
OBJECTIVE
The purpose was to estimate the benefit of CE-BMR in the setting of architectural distortion detected mammographically through a systematic review and meta-analysis of the literature.
METHODS
METHODS
A search of MEDLINE and EMBASE databases were conducted in 2020. Based on the PRISMA guidelines, an analysis was performed using the chi-square test of independence to determine if there was a significant association between the result of the test (positive or negative) and the participant condition (malignant or non-malignant).
RESULTS
RESULTS
Four studies were available. The negative predictive value (NPV) was 98.3% to 100%. The result of the chi-square indicated that there was significant association between the participant test result and the participant condition for the included publications (X(1,175)2= 84.051, p = 0.0001).
CONCLUSIONS
CONCLUSIONS
The high NPV could allow for deferral of a biopsy in favor of a short-interval imaging follow-up in the setting of a negative CE-BMR.