Résumé
Indocyanine green (ICG) fluorescence has proven to be a high potential navigation tool during liver surgery; however, its optimal usage is still far from being standardized. A systematic review was conducted on MEDLINE/PubMed for English articles that contained the information of dose and timing of ICG administration until February 2021. Successful rates of tumor detection and liver segmentation, as well as tumor/patient background and imaging settings were also reviewed. The quality assessment of the articles was performed in accordance with the Scottish Intercollegiate Guidelines Network (SIGN). Out of initial 311 articles, a total of 72 manuscripts were obtained. The quality assessment of the included studies revealed usually low; only 9 articles got qualified as high quality. Forty articles (55%) focused on open resections, whereas 32 articles (45%) on laparoscopic and robotic liver resections. Thirty-four articles (47%) described tumor detection ability, and 25 articles (35%) did liver segmentation ability, and the others (18%) did both abilities. Negative staining was reported (42%) more than positive staining (32%). For tumor detection, majority used the dose of 0.5 mg/kg within 14 days before the operation day, and an additional administration (0.02-0.5 mg/kg) in case of longer preoperative interval. Tumor detection rate was reported to be 87.4% (range, 43%-100%) with false positive rate reported to be 10.5% (range, 0%-31.3%). For negative staining method, the majority used 2.5 mg/body, ranging from 0.025 to 25 mg/body. For positive staining method, the majority used 0.25 mg/body, ranging from 0.025 to 12.5 mg/body. Successful segmentation rate was 88.0% (range, 53%-100%). The time point and dose of ICG administration strongly needs to be tailored case by case in daily practice, due to various tumor/patient backgrounds and imaging settings.
Sections du résumé
BACKGROUND
Indocyanine green (ICG) fluorescence has proven to be a high potential navigation tool during liver surgery; however, its optimal usage is still far from being standardized.
METHODS
A systematic review was conducted on MEDLINE/PubMed for English articles that contained the information of dose and timing of ICG administration until February 2021. Successful rates of tumor detection and liver segmentation, as well as tumor/patient background and imaging settings were also reviewed. The quality assessment of the articles was performed in accordance with the Scottish Intercollegiate Guidelines Network (SIGN).
RESULTS
Out of initial 311 articles, a total of 72 manuscripts were obtained. The quality assessment of the included studies revealed usually low; only 9 articles got qualified as high quality. Forty articles (55%) focused on open resections, whereas 32 articles (45%) on laparoscopic and robotic liver resections. Thirty-four articles (47%) described tumor detection ability, and 25 articles (35%) did liver segmentation ability, and the others (18%) did both abilities. Negative staining was reported (42%) more than positive staining (32%). For tumor detection, majority used the dose of 0.5 mg/kg within 14 days before the operation day, and an additional administration (0.02-0.5 mg/kg) in case of longer preoperative interval. Tumor detection rate was reported to be 87.4% (range, 43%-100%) with false positive rate reported to be 10.5% (range, 0%-31.3%). For negative staining method, the majority used 2.5 mg/body, ranging from 0.025 to 25 mg/body. For positive staining method, the majority used 0.25 mg/body, ranging from 0.025 to 12.5 mg/body. Successful segmentation rate was 88.0% (range, 53%-100%).
CONCLUSION
The time point and dose of ICG administration strongly needs to be tailored case by case in daily practice, due to various tumor/patient backgrounds and imaging settings.
Identifiants
pubmed: 35121701
doi: 10.1097/SLA.0000000000005406
pii: 00000658-202206000-00001
doi:
Substances chimiques
Indocyanine Green
IX6J1063HV
Types de publication
Journal Article
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
1025-1034Commentaires et corrections
Type : CommentIn
Informations de copyright
Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc.
Déclaration de conflit d'intérêts
The authors report no conflicts of interest.
Références
Ban D, Tanabe M, Kumamaru H, et al. Safe dissemination of laparoscopic liver resection in 27,146 cases between 2011 and 2017 From the National Clinical Database of Japan. Ann Surg 2021; 274:1043–1050.
Olthof PB, Elfrink AKE, Marra E, et al. Volume-outcome relationship of liver surgery: a nationwide analysis. Br J Surg 2020; 107:917–926.
Rackauskas R, Bausys A, Sokolovas V, et al. Short- and long-term outcomes of surgery for colorectal and non-colorectal liver metastasis: a report from a single center in the Baltic country. World J Surg Oncol 2020; 18:164.
Benedetti Cacciaguerra A, Gorgec B, Cipriani F, et al. Risk factors of positive resection margin in laparoscopic and open liver surgery for colorectal liver metastases: a new perspective in the perioperative assessment: a European multicenter study. Ann Surg 2022; 275:e213–e221.
Marino MV, Podda M, Fernandez CC, et al. Theapplication of indocyanine green-fluorescence imaging during robotic-assisted liver resection for malignant tumors: a single-arm feasibility cohort study. HPB (Oxford) 2020; 22:422–431.
Nishino H, Seo S, Hatano E, et al. What is aprecise anatomic resection of the liver? Proposal of a new evaluation method in the era of fluorescence navigation surgery. J Hepatobiliary Pancreat Sci 2021; 28:479–488.
Wakabayashi T, Benedetti Cacciaguerra A, Ciria R, et al. Landmarks to identify segmental borders of the liver: a review prepared for PAM-HBP expert consensus meeting. J Hepatobiliary Pancreat Sci 2022; 29:82–98.
Reinhart MB, Huntington CR, Blair LJ, et al. Indocyanine green: historical context, current applications, and future considerations. Surg Innov 2016; 23:166–175.
Kobayashi K, Kawaguchi Y, Kobayashi Y, et al. Identification of liver lesions using fluorescence imaging: comparison of methods for administering indocyanine green. HPB (Oxford) 2021; 23:262–269.
Wang X, Teh CSC, Ishizawa T, et al. Consensus guidelines for the use of fluorescence imaging in hepatobiliary surgery. Ann Surg 2021; 274:97–106.
Majlesara A, Golriz M, Hafezi M, et al. Indocyanine green fluorescence imaging in hepatobiliary surgery. Photodiagnosis Photodyn Ther 2017; 17:208–215.
Berardi G, Igarashi K, Li CJ, et al. Parenchymal sparing anatomical liver resections with full laparoscopic approach: description of technique and short-term results. Ann Surg 2021; 273:785–791.
Mehdorn AS, Beckmann JH, Braun F, et al. Usability of indocyanine green in robot-assisted hepatic surgery. J Clin Med 2021; 10:456.
Abo T, Nanashima A, Tobinaga S, et al. Usefulness of intraoperative diagnosis of hepatic tumors located at the liver surface and hepatic segmental visualization using indocyanine green-photodynamic eye imaging. Eur J Surg Oncol 2015; 41:257–264.
Tummers QR, Hoogstins CE, Peters AA, et al. The value of intraoperative near-infrared fluorescence imaging based on enhanced permeability and retention of indocyanine green: feasibility and false-positives in ovarian cancer. PLoS One 2015; 10:e0129766.
Liberale G, Bourgeois P, Larsimont D, et al. Indocyanine green fluorescence-guided surgery after IV injection in metastatic colorectal cancer: A systematic review. Eur J Surg Oncol 2017; 43:1656–1667.
Nanashima A, Tominaga T, Sumida Y, et al. Indocyanine green identification for tumor infiltration or metastasis originating from hepatocellular carcinoma. Int J Surg Case Rep 2018; 46:56–61.
Zhang YM, Shi R, Hou JC, et al. Liver tumor boundaries identified intraoperatively using real-time indocyanine green fluorescence imaging. J Cancer Res Clin Oncol 2017; 143:51–58.
Lim HJ, Chiow AKH, Lee LS, et al. Novel method of intraoperative liver tumour localisation with indocyanine green and near-infrared imaging. Singapore Med J 2021; 62:182–189.
Cheung TT, Ma KW, She WH, et al. Pure laparoscopic hepatectomy with augmented reality-assisted indocyanine green fluorescence versus open hepatectomy for hepatocellular carcinoma with liver cirrhosis: a propensity analysis at a single center. Asian J Endosc Surg 2018; 11:104–111.
Moher D, Liberati A, Tetzlaff J, et al. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 2009; 339:b2535.
Petrie JC, Grimshaw JM, Bryson A. The Scottish Intercollegiate Guidelines Network Initiative: getting validated guidelines into local practice. Health Bull (Edinb) 1995; 53:345–348.
Alfano MS, Molfino S, Benedicenti S, et al. Intraoperative ICG-based imaging of liver neoplasms: a simple yet powerful tool. Preliminary results. Surg Endosc 2019; 33:126–134.
Dip F, Boni L, Bouvet M, et al. Consensus conference statement on the general use of near-infrared fluorescence imaging and indocyanine green guided surgery: results of a Modified Delphi Study. Ann Surg 2022; 275:685–691.
Ishizawa T, Fukushima N, Shibahara J, et al. Real-time identification of liver cancers by using indocyanine green fluorescent imaging. Cancer 2009; 115:2491–2504.
Kawaguchi Y, Nagai M, Nomura Y, et al. Usefulness of indocyanine green-fluorescence imaging during laparoscopic hepatectomy to visualize subcapsular hard-to-identify hepatic malignancy. J Surg Oncol 2015; 112:514–516.
van der Vorst JR, Schaafsma BE, Hutteman M, et al. Near-infrared fluorescence-guided resection of colorectal liver metastases. Cancer 2013; 119:3411–3418.
Tanaka T, Takatsuki M, Hidaka M, et al. Is a fluorescence navigation system with indocyanine green effective enough to detect liver malignancies? J Hepatobiliary Pancreat Sci 2014; 21:199–204.
Morita Y, Sakaguchi T, Unno N, et al. Detection of hepatocellular carcinomas with near-infrared fluorescence imaging using indocyanine green: its usefulness and limitation. Int J Clin Oncol 2013; 18:232–241.
Masuda K, Kaneko J, Kawaguchi Y, et al. Diagnostic accuracy of indocyanine green fluorescence imaging and multidetector row computed tomography for identifying hepatocellular carcinoma with liver explant correlation. Hepatol Res 2017; 47:1299–1307.
Handgraaf HJM, Boogerd LSF, Hoppener DJ, et al. Long-term follow-up after near-infrared fluorescence-guided resection of colorectal liver metas-tases: aretrospective multicenter analysis. Eur J Surg Oncol 2017; 43:1463–1471.
Boogerd LS, Handgraaf HJ, Lam HD, et al. Laparoscopic detection and resection of occult liver tumors of multiple cancer types using real-time near-infrared fluorescence guidance. Surg Endosc 2017; 31:952–961.
Pesce A, Piccolo G, La Greca G, et al. Utility of fluorescent cholangiography during laparoscopic cholecystectomy: a systematic review. World J Gastroenterol 2015; 21:7877–7883.
Felli E, Ishizawa T, Cherkaoui Z, et al. Laparoscopic anatomical liver resection for malignancies using positive or negative staining technique with intraoperative indocyanine green-fluorescence imaging. HPB (Oxford) 2021; 23:1647–1655.
Urade T, Sawa H, Iwatani Y, et al. Laparoscopic anatomical liver resection using indocyanine green fluorescence imaging. Asian J Surg 2020; 43:362–368.
Karampinis I, Ronellenfitsch U, Mertens C, et al. Indocyanine green tissue angiography affects anastomotic leakage after esophagectomy. A retrospective, case-control study. Int J Surg 2017; 48:210–214.
Ohdaira H, Yoshida M, Okada S, et al. New method of indocyanine green fluorescence sentinel node mapping for early gastric cancer. Ann Med Surg (Lond) 2017; 20:61–65.
Jones GE, King VA, Yoo A, et al. Use of new technologies in implant-based breast reconstruction. Semin Plast Surg 2019; 33:258–263.
Ueno M, Hayami S, Sonomura T, et al. Concomitant use of indocyanine green fluorescence imaging and interventional radiology for detection of liver segments during laparoscopic anatomical liver resection: pilot feasibility study. Surg Laparosc Endosc Percutan Tech 2019; 29:242–246.
Aoki T, Yasuda D, Shimizu Y, et al. Image-guided liver mapping using fluorescence navigation system with indocyanine green for anatomical hepatic resection. World J Surg 2008; 32:1763–1767.
Ishizawa T, Zuker NB, Kokudo N, et al. Positive and negative staining of hepatic segments by use of fluorescent imaging techniques during laparoscopic hepatectomy. Arch Surg 2012; 147:393–394.
Kobayashi Y, Kawaguchi Y, Kobayashi K, et al. Portal vein territory identification using indocyanine green fluorescence imaging: Technical details and short-term outcomes. J Surg Oncol 2017; 116:921–931.
Uchiyama K, Ueno M, Ozawa S, et al. Combined intraoperative use of contrast-enhanced ultrasonography imaging using a sonazoid and fluorescence navigation system with indocyanine green during anatomical hepatectomy. Langenbecks Arch Surg 2011; 396:1101–1107.
Aoki T, Koizumi T, Mansour DA, et al. Ultrasound-guided preoperative positive percutaneous indocyanine green fluorescence staining for laparoscopic anatomical liver resection. J Am Coll Surg 2020; 230:e7–e12.
Xu Y, Chen M, Meng X, et al. Laparoscopic anatomical liver resection guided by real-time indocyanine green fluorescence imaging: experience and lessons learned from the initial series in a single center. Surg Endosc 2020; 34:4683–4691.
Marino MV, Di Saverio S, Podda M, et al. The application of indocyanine green fluorescence imaging during robotic liver resection: a case-matched study. World J Surg 2019; 43:2595–2606.
Kose E, Kahramangil B, Aydin H, et al. A comparison of indocyanine green fluorescence and laparoscopic ultrasound for detection of liver tumors. HPB (Oxford) 2020; 22:764–769.
Yamada Y, Ohno M, Fujino A, et al. Fluorescence-guided surgery for hepatoblastoma with indocyanine green. Cancers (Basel) 2019; 11:1215.
Benedicenti S, Molfino S, Alfano MS, et al. Indocyanine-green fluorescence-GUIDED liver resection of metastasis from squamous cell carcinoma invading the biliary tree. Case Rep Gastrointest Med 2018; 2018:5849816.
Harada N, Ishizawa T, Muraoka A, et al. Fluorescence navigation hepatectomy by visualization of localized cholestasis from bile duct tumor infiltration. J Am Coll Surg 2010; 210:e2–e6.
Malerba V, Benedetti Cacciaguerra A, Zimmitti G, et al. From PVE to HVE to fully laparoscopic rescue ALPPS: a case report of multidisciplinary management of giant HCC. Hepatoma Research 2021; 7:19.
Gorgec B, Suhool A, Al-Jarrah R, et al. Surgical technique and clinical results of one- or two-stage laparoscopic right hemihepatectomy after portal vein embolization in patients with initially unresectable colorectal liver metastases: a case series. Int J Surg 2020; 77:69–75.
Satou S, Ishizawa T, Masuda K, et al. Indocyanine green fluorescent imaging for detecting extrahepatic metastasis of hepatocellular carcinoma. J Gastroenterol 2013; 48:1136–1143.
Liberale G, Vankerckhove S, Caldon MG, et al. Fluorescence imaging after indocyanine green injection for detection of peritoneal metastases in patients undergoing cytoreductive surgery for peritoneal carcinomatosis from colorectal cancer: a pilot study. Ann Surg 2016; 264:1110–1115.
Xiong L, Gazyakan E, Yang W, et al. Indocyanine green fluorescence-guided sentinel node biopsy: a meta-analysis on detection rate and diagnostic performance. Eur J Surg Oncol 2014; 40:843–849.
Gotoh K, Yamada T, Ishikawa O, et al. A novel image-guided surgery of hepatocellular carcinoma by indocyanine green fluorescence imaging navigation. J Surg Oncol 2009; 100:75–79.
Aoki T, Murakami M, Yasuda D, et al. Intraoperative fluorescent imaging using indocyanine green for liver mapping and cholangiography. J Hepatobiliary Pancreat Sci 2010; 17:590–594.
Uchiyama K, Ueno M, Ozawa S, et al. Combined use of contrast-enhanced intraoperative ultrasonography and a fluorescence navigation system for identifying hepatic metastases. World J Surg 2010; 34:2953–2959.
Ishizuka M, Kubota K, Kita J, et al. Intraoperative observation using a fluorescence imaging instrument during hepatic resection for liver metastasis from colorectal cancer. Hepatogastroenterology 2012; 59:90–92.
Peloso A, Franchi E, Canepa MC, et al. Combined use of intraoperative ultrasound and indocyanine green fluorescence imaging to detect liver metastases from colorectal cancer. HPB (Oxford) 2013; 15:928–934.
Sakoda M, Ueno S, Iino S, et al. Anatomical laparoscopic hepatectomy for hepatocellular carcinoma using indocyanine green fluorescence imaging. J Laparoendosc Adv Surg Tech A 2014; 24:878–882.
Kudo H, Ishizawa T, Tani K, et al. Visualization of subcapsular hepatic malignancy by indocyanine-green fluorescence imaging during laparoscopic hepatectomy. Surg Endosc 2014; 28:2504–2508.
Ishizawa T, Masuda K, Urano Y, et al. Mechanistic background and clinical applications of indocyanine green fluorescence imaging of hepatocellular carcinoma. Ann Surg Oncol 2014; 21:440–448.
Kurihara T, Yamashita Y, Yoshida Y, et al. Indocyanine green fluorescent imaging for hepatic resection of the right hepatic vein drainage area. JAm Coll Surg 2015; 221:e49–e53.
Inoue Y, Saiura A, Arita J, et al. Hepatic vein-oriented liver resection using fusion indocyanine green fluorescence imaging. Ann Surg 2015; 262:e98–e99.
Miyata A, Ishizawa T, Tani K, et al. Reappraisal of a dye-staining technique for anatomic hepatectomy by the concomitant use of indocyanine green fluorescence imaging. J Am Coll Surg 2015; 221:e27–e36.
Tummers QR, Verbeek FP, Prevoo HA, et al. First experience on laparoscopic near-infrared fluorescence imaging of hepatic uveal melanoma metastases using indocyanine green. Surg Innov 2015; 22:20–25.
Takahashi H, Zaidi N, Berber E. An initial report on the intraoperative use of indocyanine green fluorescence imaging in the surgical management of liver tumorss. J Surg Oncol 2016; 114:625–629.
Kaibori M, Matsui K, Ishizaki M, et al. Intraoperative detection ofsuperficial liver tumors by fluorescence imaging using indocyanine green and 5-aminolevulinic| acid. Anticancer Res 2016; 36:1841–1849.
Barabino G, Porcheron J, Cottier M, et al. Improving surgical resection of metastatic liver tumors with near-infrared optical-guided fluorescence imaging. Surg Innov 2016; 23:354–359.
Kawaguchi Y, Nomura Y, Nagai M, et al. Liver transection using indocyanine green fluorescence imaging and hepatic vein clamping. Br J Surg 2017; 104:898–906.
Terasawa M, Ishizawa T, Mise Y, et al. Applications of fusion-fluorescence imaging using indocyanine green in laparoscopic hepatectomy. Surg Endosc 2017; 31:5111–5118.
Meng X, Wang H, Xu Y, et al. Indocyanine green fluorescence image-guided total laparoscopic living donor right hepatectomy: the first case report from Mainland China. Int J Surg Case Rep 2018; 53:406–409.
Nomi T, Hokuto D, Yoshikawa, et al. A novel navigation for laparoscopic anatomic liver resection using indocyanine green fluorescence. Ann Surg Oncol 2018; 25:3982.
Nishino H, Hatano E, Seo S, et al. Real-time navigation for liver surgery using projection mapping with indocyanine green fluorescence: development of the novel medical imaging projection system. Ann Surg 2018; 267:1134–1140.
Lieto E, Galizia G, Cardella F, et al. Indocyanine green fluorescence imaging-guided surgery in primary and metastatic liver tumors. Surg Innov 2018; 25:62–68.
Peyrat P, Blanc E, Guillermet S, et al. HEPATOFLUO: a prospective monocentric study assessing the benefits of indocyanine green (ICG) fluorescence for hepatic surgery. J Surg Oncol 2018; 117:922–927.
Ueno M, Hayami S, Sonomura T, et al. Indocyanine green fluorescence imaging techniques and interventional radiology during laparoscopic anatomical liver resection (with video). Surg Endosc 2018; 32:1051–1055.
Nanashima A, Yano K, Tobinaga S. Efficacy of hepatic segmental visualization using indocyanine green photodynamic eye imaging. World J Surg 2019; 43:1308–1312.
Chiba N, Shimazu M, Ochiai S, et al. Resection ofhepatic lesions perfused by the cholecystic vein using indocyanine green navigation in patients with cT2 gallbladder cancer. World J Surg 2019; 43:608–614.
Gon H, Komatsu S, Murakami S, et al. Real-time navigation during hepa-tectomy using fusion indocyanine green-fluorescence imaging: protocol for a prospective cohort study. BMJ Open 2019; 9:e030233.
Yoshioka M, Taniai N, Kawano Y, et al. Laparoscopic repeat hepatectomy with indocyanine green fluorescence navigation: a case report. J Nippon Med Sch 2019; 86:291–295.
Kubo N, Araki K, Harimoto N, et al. Hepatic resection for the right hepatic vein drainage area with indocyanine green fluorescent imaging navigation. J Hepatobiliary Pancreat Sci 2020; 27:371–379.
Ito D, Ishizawa T, Hasegawa K. Laparoscopic positive staining of hepatic segments using indocyanine green-fluorescence imaging. J Hepatobiliary Pancreat Sci 2020; 27:441–443.
He JM, Zhen ZP, Ye Q, et al. Laparoscopic anatomical segment VII resection for hepatocellular carcinoma using the glissonian approach with indocyanine green dye fluorescence. J Gastrointest Surg 2020; 24:1228–1229.
Pansa A, Torzilli G, Procopio F, et al. Indocyanine-green fluorescence guided anatomical segmentectomy for HCC with portal thrombosis: the counter-fluorescence technique. Updates Surg 2020; 72:219–222.
Li CG, Zhou ZP, Tan XL, et al. Robotic resection of liver focal nodal hyperplasia guided by indocyanine green fluorescence imaging: a preliminary analysis of23 cases. World JGastrointest Oncol 2020; 12:1407–1415.
Achterberg FB, Sibinga Mulder BG, Meijer RPJ, et al. Real-time surgical margin assessment using ICG-fluorescence during laparoscopic and robot-assisted resections of colorectal liver metastases. Ann Transl Med 2020; 8:1448.
Li B, Liu T, Zhang Y, et al. Retroperitoneal laparoscopic hepatectomy of recurrent hepatocellular carcinoma: case report and literature review. BMC Gastroenterol 2020; 20:278.
Tashiro Y, Aoki T, Hirai T, et al. Pathological validity of using near-infrared fluorescence imaging for securing surgical margins during liver resection. Anticancer Res 2020; 40:3873–3882.
He K, Hong X, Chi C, et al. A new method of near-infrared fluorescence image-guided hepatectomy for patients with hepatolithiasis: a randomized controlled trial. Surg Endosc 2020; 34:4975–4982.
Lu H, Gu J, Qian XF, et al. Indocyanine green fluorescence navigation in laparoscopic hepatectomy: a retrospective single-center study of 120 cases. Surg Today 2021; 51:695–702.
Li YP, Ma ZG, Tuxun T, et al. The application oflaparoscopy combined with indocyanine green fluorescence imaging technique for hepatic cystic echinococcosis. BMC Surg 2020; 20:249.
Miyashita S, Hatano E, Tada M, et al. Hepatectomy using a novel cartbased indocyanine green fluorescence imaging system. Surg Today 2020; 50:1308–1313.
Yao S, Zhang L, Ma J, et al. Precise righthemihepatectomy forthe treatment of hepatocellular carcinoma guided by fusion ICG fluorescence imaging. J Cancer 2020; 11:2465–2475.
Zhang P, Luo H, Zhu W, et al. Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging. Surg Endosc 2020; 34:3449–3459.
Kim J, Hong SK, Lim J, et al. Demarcating the exact midplane of the liver using indocyanine green near-infrared fluorescence imaging during laparo-scopic donor hepatectomy. Liver Transpl 2021; 27:830–839.
Procopio F, Torzilli G, Franchi E, et al. Ultrasound-guided anatomical liver resection using a compression technique combined with indocyanine green fluorescence imaging. HPB (Oxford) 2021; 23:206–211.
Matsumura M, Seyama Y, Ishida H, et al. Indocyanine green fluorescence navigation for hepatocellular carcinoma with bile duct tumor thrombus: a case report. Surg Case Rep 2021; 7:18.
Bijlstra OD, Achterberg FB, Tummers Q, et al. Near-infrared fluorescence-guided metastasectomy for hepatic gastrointestinal stromal tumor metastases using indocyanine green: a case report. Int J Surg Case Rep 2021; 78:250–253.
Zheng JH, Zhai ST, Liang X. Laparoscopic portal territory hepatectomy (extended segment 5) by an indocyanine green fluorescent dual staining technique (video). J Gastrointest Surg 2021; 25:329–330.