Concurrent Validity of a Continuous Glucose-Monitoring System at Rest and During and Following a High-Intensity Interval Training Session.
carbohydrate
nutrition
protein
sport
technology
Journal
International journal of sports physiology and performance
ISSN: 1555-0273
Titre abrégé: Int J Sports Physiol Perform
Pays: United States
ID NLM: 101276430
Informations de publication
Date de publication:
01 04 2022
01 04 2022
Historique:
received:
06
05
2021
revised:
24
08
2021
accepted:
08
09
2021
entrez:
22
2
2022
pubmed:
23
2
2022
medline:
21
4
2022
Statut:
ppublish
Résumé
To assess the concurrent validity of a continuous blood-glucose-monitoring system (CGM) postbreakfast, preexercise, exercise, and postexercise, while assessing the impact of 2 different breakfasts on the observed level of validity. Eight nondiabetic recreational athletes (age = 30.8 [9.5] y; height = 173.6 [6.6] cm; body mass = 70.3 [8.1] kg) took part in the study. Blood glucose concentration was monitored every 10 minutes using both a CGM (FreeStyle Libre, Abbott, France) and finger-prick blood glucose measurements (FreeStyle Optimum) over 4 different periods (postbreakfast, preexercise, exercise, and postexercise). Two different breakfasts (carbohydrates [CHO] and protein oriented) over 2 days (2 × 2 d in total) were used. Statistical analyses included the Bland-Altman method, standardized mean bias (expressed in standardized units), median absolute relative difference, and the Clarke error grid analysis. Overall, mean bias was trivial to small at postbreakfast (effect size ± 90% confidence limits: -0.12 ± 0.08), preexercise (-0.08 ± 0.08), and postexercise (0.25 ± 0.14), while moderate during exercise (0.66 ± 0.09). A higher median absolute relative difference was observed during exercise (13.6% vs 7%-9.5% for the other conditions). While there was no effect of the breakfast type on the median absolute relative difference results, error grid analysis revealed a higher value in zone D (ie, clinically unsafe zone) during exercise for CHO (10.5%) compared with protein (1.6%). The CGM device examined in this study can only be validly used at rest, after both a CHO and protein-rich breakfast. Using CGM to monitor blood glucose concentration during exercise is not recommended. Moreover, the accuracy decreased when CHO were consumed before exercise.
Identifiants
pubmed: 35193110
doi: 10.1123/ijspp.2021-0222
doi:
Substances chimiques
Blood Glucose
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM