Non-ischemic cerebral enhancing lesions after thrombectomy: a multicentric retrospective French national registry.
Brain-enhancing lesions
Endovascular therapy
MRI
Mechanical thrombectomy
NICE
Stroke
Journal
Neuroradiology
ISSN: 1432-1920
Titre abrégé: Neuroradiology
Pays: Germany
ID NLM: 1302751
Informations de publication
Date de publication:
May 2022
May 2022
Historique:
received:
09
11
2021
accepted:
17
02
2022
pubmed:
25
2
2022
medline:
15
4
2022
entrez:
24
2
2022
Statut:
ppublish
Résumé
To report the occurrence of non-ischemic cerebral enhancing (NICE) lesions following mechanical thrombectomy (MT) through the retrospective French nationwide registry of NICE lesions. All thrombectomy capable stroke centers (TSC) in France were invited to fill out a questionnaire disseminated through a trainee-led research network (JENI-RC: Jeunes en Neuroradiologie Interventionnelle-Research Collaborative). NICE lesions were defined according to previous literature as delayed onset punctate, nodular, or annular foci enhancements with peri-lesion edema and vascular distribution in the territory of the MT with no other confounding disease. All 43 TSC French centers responded. Three patients were reported by 3 different centers over a total of 34,824 MT (2015-2020). Patient no. 1 developed symptomatic NICE lesions 8 weeks after MT with combination of aspiration and stentriever for a right middle cerebral artery occlusion. Patient no. 2 developed asymptomatic NICE lesions 5 weeks after MT with direct thromboaspiration for a right middle cerebral artery occlusion. Patient no. 3 developed symptomatic NICE lesions 6 weeks after MT with direct thromboaspiration, and combination of aspiration and stentriever for a basilar artery occlusion. This study provides evidence that NICE lesions following MT are a possible rare complication with a similar presentation as previously described following endovascular aneurysm treatment. Both radiologists and neurologists should be aware of this adverse event and make use of MRI contrast agents in case of unexplained symptoms/images during follow-up after MT.
Identifiants
pubmed: 35199209
doi: 10.1007/s00234-022-02919-8
pii: 10.1007/s00234-022-02919-8
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1037-1042Informations de copyright
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Références
Shotar E, Law-Ye B, Baronnet-Chauvet F et al (2016) Non-ischemic cerebral enhancing lesions secondary to endovascular aneurysm therapy: nickel allergy or foreign body reaction? Case series and review of the literature. Neuroradiology 58:877–885. https://doi.org/10.1007/s00234-016-1699-5
doi: 10.1007/s00234-016-1699-5
pubmed: 27216205
Shotar E, Labeyrie M-A, Biondi A et al (2021) Non-ischemic cerebral enhancing lesions after intracranial aneurysm endovascular repair: a retrospective French national registry. J NeuroInterv Surg: neurintsurg-2021–017992. https://doi.org/10.1136/neurintsurg-2021-017992
Shapiro M, Ollenschleger MD, Baccin C et al (2015) Foreign body emboli following cerebrovascular interventions: clinical, radiographic, and histopathologic features. Am J Neuroradiol 36:2121–2126. https://doi.org/10.3174/ajnr.A4415
doi: 10.3174/ajnr.A4415
pubmed: 26294650
pmcid: 7964857
Mehta RI, Rai AT, Vos JA et al (2019) Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency. J NeuroInterv Surg 11:1191–1196. https://doi.org/10.1136/neurintsurg-2018-014684
doi: 10.1136/neurintsurg-2018-014684
pubmed: 31103995
pmcid: 6902067
Abbasi M, Dai D, Liu Y et al (2021) Iatrogenic foreign materials associated with retrieved clot tissue via mechanical thrombectomy. Am J Neuroradiol. https://doi.org/10.3174/ajnr.A7106
doi: 10.3174/ajnr.A7106
pubmed: 34916206
Kerleroux B, Bourcier R, Rouchaud A et al (2021) Interventional neuroradiology trainee-led research collaborative JENI, moving forward. J Neuroradiol 48:137–138. https://doi.org/10.1016/j.neurad.2021.01.007
doi: 10.1016/j.neurad.2021.01.007
pubmed: 33515598
Chu Y-T, Lee K-P, Chen C-H et al (2020) Contrast-Induced encephalopathy after endovascular thrombectomy for acute ischemic stroke. Stroke 51:3756–3759. https://doi.org/10.1161/STROKEAHA.120.031518
doi: 10.1161/STROKEAHA.120.031518
pubmed: 33121385
Lorentzen AO, Nome T, Bakke SJ et al (2016) Cerebral foreign body reaction after carotid aneurysm stenting. Interv Neuroradiol 22:53–57. https://doi.org/10.1177/1591019915609171
doi: 10.1177/1591019915609171
pubmed: 26510943
pmcid: 4757375
Mehta RI, Mehta RI (2018) Hydrophilic polymer embolism: implications for manufacturing, regulation, and postmarket surveillance of coated intravascular medical devices. J Patient Saf. Publish Ahead of Print. https://doi.org/10.1097/PTS.0000000000000473
Stanley JRL, Tzafriri AR, Regan K et al (2016) Particulates from hydrophilic-coated guiding sheaths embolise to the brain. EuroIntervention 11:1435–1441. https://doi.org/10.4244/EIJY15M03_02
doi: 10.4244/EIJY15M03_02
pubmed: 25735934
pmcid: 4639467
Fealey ME, Edwards WD, Giannini C et al (2008) Complications of endovascular polymers associated with vascular introducer sheaths and metallic coils in 3 patients, with literature review. Am J Surg Pathol 32:1310–1316. https://doi.org/10.1097/PAS.0b013e318165582a
doi: 10.1097/PAS.0b013e318165582a
pubmed: 18636015
Grewal SS, López Del Valle EM, Gupta V et al (2015) Neurological changes with abnormal brain reactivity following coiling of cerebral aneurysm. Possible reactivity to endovascular devices and material? J Vasc Interv Neurol 8:28–36
pubmed: 26301029
pmcid: 4535604