Technical note: Sources of systemic error in total body irradiation and total skin electron therapy in vivo measurements using nanoDot optically stimulated luminescence dosimeters within high-efficiency clinics.
OSLD
element sensitivity
total body irradiation
total skin electron therapy
Journal
Medical physics
ISSN: 2473-4209
Titre abrégé: Med Phys
Pays: United States
ID NLM: 0425746
Informations de publication
Date de publication:
May 2022
May 2022
Historique:
revised:
09
01
2022
received:
29
10
2021
accepted:
13
02
2022
pubmed:
26
2
2022
medline:
12
5
2022
entrez:
25
2
2022
Statut:
ppublish
Résumé
To identify sources of systemic errors and estimate their effects, especially the vendor-provided sensitivity S Calibration nanoDot OSLDs were irradiated 50-300cGy under reference conditions. Raw OSLD readings M S Our findings suggest that M
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
3489-3496Informations de copyright
© 2022 American Association of Physicists in Medicine.
Références
Jursinic PA. Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements. Med Phys. 2007;34:4594.
Akselrod MS, McKeever SWS, Botter-Jensen L. Optically stimulated luminescence and its use in medical dosimetry. Radiat Meas. 2007;41:S78-S99. S1.
Yusof FH, Ung NM, Wong JHD, et al. On the use of optically stimulated luminescent dosimeter for surface dose measurement during radiotherapy. PLoS One. 2015;10(6):e0128544. https://doi.org/10.1371/journal.pone.0128544.
Kry SF, Alvarez P, Cygler JE, et al. AAPM TG 191: clinical use of luminescent dosimeters: tLDs and OSLDs. Med Phys. 2020;47:e19-e51. https://doi.org/10.1002/mp.13839.
Butson M, Haque M, Smith L, et al. Practical time considerations for optically stimulated luminescent dosimetry (OSLD) in total body irradiation. Aust Phys Eng Sci Med. 2017;40(1):167-171. https://doi.org/10.1007/s13246-016-0504-4.
Alvarez P, Kry SF, Stingo F, Followill D. TLD and OSLD dosimetry systems for remote audits of radiotherapy external beam calibration. Radiat Meas. 2017;106:412-415. https://doi.org/10.1016/j.radmeas.2017.01.005.
Dyk JV, Galvin JM, Glasgow GP, Podgorsak EB. The physical aspects of total and half body photon irradiation. American Association of Physicists in Medicine by the American Institute of Physics; 1986. https://doi.org/10.37206/16
Karzmark CJ, Anderson J, Buffa A, et al. Total skin electron therapy: Technique and dosimetry; 1987. https://doi.org/10.37206/22.
Jursinic PA. Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose. Med Phys. 2009;37(1):132-140. https://doi.org/10.1118/1.3267489.
Omotayo AA, Cygler JE, Sawakuchi GO. The effect of different bleaching wavelengths on the sensitivity of Al2O3:C optically stimulated luminescence detectors (OSLDs) exposed to 6 MV photon beams. Med Phys. 2012;39(9):5457-5468. https://doi.org/10.1118/1.4742865.
Jursinic PA. Optically stimulated luminescent dosimeters stable response to dose after repeated bleaching. Med Phys. 2020;47(7):3191-3203. https://doi.org/10.1002/mp.14182.
Piotrowski T, Milecki P, Skórska M, Fundowicz D. Total skin electron irradiation techniques: A review. Adv Dermatol Allergol. 2013;1:50-55. https://doi.org/10.5114/pdia.2013.33379.
Kim DW, Chung WK, Shin DO, et al. Dose response of commercially available optically stimulated luminescent detector, Al2O3:C for megavoltage photons and electrons. Radiat Prot Dosim. 2012;149(2):101-108. https://doi.org/10.1093/rpd/ncr223.