Long-Term Follow-Up of the Auditory Threshold After a Fully Implantable Middle Ear Implant.
active middle ear implant
auditory rehabilitation
bone conduction threshold change
fully implantable
sensorineural hearing loss (SNHL)
Journal
Frontiers in neurology
ISSN: 1664-2295
Titre abrégé: Front Neurol
Pays: Switzerland
ID NLM: 101546899
Informations de publication
Date de publication:
2022
2022
Historique:
received:
13
12
2021
accepted:
17
01
2022
entrez:
28
2
2022
pubmed:
1
3
2022
medline:
1
3
2022
Statut:
epublish
Résumé
A fully implantable active middle ear device has been proposed and indicated for the rehabilitation of bilateral moderate or moderate-to-severe sensorineural hearing loss, assuming it would overcome the disadvantages of a conventional hearing aid. The indications have further been extended to severe or severe-to-profound forms of hearing loss in the case of an expected limited or null efficacy of hearing aids. While the literature has highlighted several positive aspects of the device, including a better quality of life related to its invisibility, the improvement of auditory and perceptual functions has not been controlled for throughout a long period of follow-up. The present study aimed to verify the behavior of the auditory threshold, especially the bone conduction (BC) component, in the implanted ear in a group of implantees affected by initial bilateral symmetric hearing loss of different severity grades. The BC threshold was assessed preoperatively at activation and at the last follow-up (ranging from 4 to 12 years) in the implanted ear, and preoperatively and at the last follow-up in the contralateral ear, to monitor eventual deteriorated values in both ears over time. The pure tone average (PTA; 250-4,000 Hz), speech reception threshold (SRT) and the maximum word recognition score as a percentage (% WRS) and in dB HL were measured in the implanted ear to verify the efficacy of the device after the first fitting at device activation. A significant worsening of the BC threshold with respect to the baseline threshold was noticed during further follow-up. When comparing the implanted ear with the contralateral ear, a significant worsening of the bone PTA was assessed in the former with respect to the contralateral ear. Despite the worsened hearing found in the implanted ears, the beneficial gains in PTA and speech audiometry observed at the first activation remained constant at the follow-up, thus showing an extension of the efficacy of this device in aiding those with up to the most severe forms of sensorineural hearing loss.
Identifiants
pubmed: 35222257
doi: 10.3389/fneur.2022.834402
pmc: PMC8866237
doi:
Types de publication
Journal Article
Langues
eng
Pagination
834402Informations de copyright
Copyright © 2022 Monini, Filippi, Salerno and Barbara.
Déclaration de conflit d'intérêts
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Références
Laryngoscope. 2019 May;129(5):1023-1024
pubmed: 30408187
Otolaryngol Clin North Am. 2019 Apr;52(2):297-309
pubmed: 30770176
Adv Otorhinolaryngol. 2010;69:59-71
pubmed: 20610915
Exp Gerontol. 2003 Apr;38(4):353-9
pubmed: 12670621
Adv Otorhinolaryngol. 2010;69:20-26
pubmed: 20610910
Acta Otolaryngol. 2020 Mar;140(3):236-241
pubmed: 32003288
Laryngoscope Investig Otolaryngol. 2020 Nov 06;5(6):1184-1191
pubmed: 33364411
Eur Arch Otorhinolaryngol. 2011 Oct;268(10):1421-5
pubmed: 21328002
Otolaryngol Head Neck Surg. 2004 Dec;131(6):904-16
pubmed: 15577788
Eur Arch Otorhinolaryngol. 2021 Nov;278(11):4289-4294
pubmed: 33386437
Otol Neurotol. 2011 Dec;32(9):1428-31
pubmed: 22072264
Acta Otolaryngol. 2011 Apr;131(4):399-404
pubmed: 21198340
Otolaryngol Head Neck Surg. 2011 Jul;145(1):100-9
pubmed: 21493292
Eur Arch Otorhinolaryngol. 2013 Jul;270(7):2027-33
pubmed: 23143506
Otolaryngol Clin North Am. 2014 Dec;47(6):941-52
pubmed: 25256656
Acta Otolaryngol. 2018 Sep;138(9):807-814
pubmed: 29852816
Acta Otolaryngol. 2017 Apr;137(4):389-397
pubmed: 27918233
Laryngoscope. 2018 Jan;128(1):210-216
pubmed: 28407310
Laryngoscope. 2018 Dec;128(12):2872-2878
pubmed: 30194720