Recommendations for Determining the Validity of Consumer Wearables and Smartphones for the Estimation of Energy Expenditure: Expert Statement and Checklist of the INTERLIVE Network.


Journal

Sports medicine (Auckland, N.Z.)
ISSN: 1179-2035
Titre abrégé: Sports Med
Pays: New Zealand
ID NLM: 8412297

Informations de publication

Date de publication:
08 2022
Historique:
accepted: 15 02 2022
pubmed: 10 3 2022
medline: 29 7 2022
entrez: 9 3 2022
Statut: ppublish

Résumé

Consumer wearables and smartphone devices commonly offer an estimate of energy expenditure (EE) to assist in the objective monitoring of physical activity to the general population. Alongside consumers, healthcare professionals and researchers are seeking to utilise these devices for the monitoring of training and improving human health. However, the methods of validation and reporting of EE estimation in these devices lacks rigour, negatively impacting on the ability to make comparisons between devices and provide transparent accuracy. The Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) is a joint European initiative of six universities and one industrial partner. The network was founded in 2019 and strives towards developing best-practice recommendations for evaluating the validity of consumer wearables and smartphones. This expert statement presents a best-practice validation protocol for consumer wearables and smartphones in the estimation of EE. The recommendations were developed through (1) a systematic literature review; (2) an unstructured review of the wider literature discussing the potential factors that may introduce bias during validation studies; and (3) evidence-informed expert opinions from members of the INTERLIVE network. The systematic literature review process identified 1645 potential articles, of which 62 were deemed eligible for the final dataset. Based on these studies and the wider literature search, a validation framework is proposed encompassing six key domains for validation: the target population, criterion measure, index measure, testing conditions, data processing and the statistical analysis. The INTERLIVE network recommends that the proposed protocol, and checklists provided, are used to standardise the testing and reporting of the validation of any consumer wearable or smartphone device to estimate EE. This in turn will maximise the potential utility of these technologies for clinicians, researchers, consumers, and manufacturers/developers, while ensuring transparency, comparability, and replicability in validation. PROSPERO ID: CRD42021223508.

Sections du résumé

BACKGROUND
Consumer wearables and smartphone devices commonly offer an estimate of energy expenditure (EE) to assist in the objective monitoring of physical activity to the general population. Alongside consumers, healthcare professionals and researchers are seeking to utilise these devices for the monitoring of training and improving human health. However, the methods of validation and reporting of EE estimation in these devices lacks rigour, negatively impacting on the ability to make comparisons between devices and provide transparent accuracy.
OBJECTIVES
The Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) is a joint European initiative of six universities and one industrial partner. The network was founded in 2019 and strives towards developing best-practice recommendations for evaluating the validity of consumer wearables and smartphones. This expert statement presents a best-practice validation protocol for consumer wearables and smartphones in the estimation of EE.
METHODS
The recommendations were developed through (1) a systematic literature review; (2) an unstructured review of the wider literature discussing the potential factors that may introduce bias during validation studies; and (3) evidence-informed expert opinions from members of the INTERLIVE network.
RESULTS
The systematic literature review process identified 1645 potential articles, of which 62 were deemed eligible for the final dataset. Based on these studies and the wider literature search, a validation framework is proposed encompassing six key domains for validation: the target population, criterion measure, index measure, testing conditions, data processing and the statistical analysis.
CONCLUSIONS
The INTERLIVE network recommends that the proposed protocol, and checklists provided, are used to standardise the testing and reporting of the validation of any consumer wearable or smartphone device to estimate EE. This in turn will maximise the potential utility of these technologies for clinicians, researchers, consumers, and manufacturers/developers, while ensuring transparency, comparability, and replicability in validation.
TRIAL REGISTRATION
PROSPERO ID: CRD42021223508.

Identifiants

pubmed: 35260991
doi: 10.1007/s40279-022-01665-4
pii: 10.1007/s40279-022-01665-4
pmc: PMC9325806
doi:

Types de publication

Systematic Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

1817-1832

Informations de copyright

© 2022. The Author(s).

Références

Tankovska H. Fitness Trackers—Statistics and Facts. Statista; 2020. https://www.statista.com/topics/4393/fitness-and-activity-tracker/ . Accessed 24 Feb 2021.
O’Dea S. Smartphone users worldwide 2016–2021. Statista; 2020. https://www.statista.com/statistics/330695/number-of-smartphone-users-worldwide/ . Accessed 24 Feb 2021.
Bunn JA, Navalta JW, Fountaine CJ, et al. Current state of commercial wearable technology in physical activity monitoring 2015–2017. Int J Exerc Sci. 2018;11:503–15.
pubmed: 29541338 pmcid: 5841672
de Weir VJB. New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol. 1949;109:1–9.
pubmed: 15394301 pmcid: 1392602 doi: 10.1113/jphysiol.1949.sp004363
Levine JA. Measurement of energy expenditure. Public Health Nutr. 2005;8:1123–32.
pubmed: 16277824 doi: 10.1079/PHN2005800
Hills AP, Mokhtar N, Byrne NM. Assessment of physical activity and energy expenditure: an overview of objective measures. Front Nutr. 2014;1:5.
pubmed: 25988109 pmcid: 4428382 doi: 10.3389/fnut.2014.00005
Schoeller DA, Van Santen E. Measurement of energy expenditure in humans by doubly labeled water method. J Appl Physiol. 1982;53:955–9.
pubmed: 6759491 doi: 10.1152/jappl.1982.53.4.955
Düking P, Giessing L, Frenkel MO, et al. Wrist-worn wearables for monitoring heart rate and energy expenditure while sitting or performing light-to-vigorous physical activity: validation study. JMIR Mhealth Uhealth. 2020;8:e16716.
pubmed: 32374274 pmcid: 7240439 doi: 10.2196/16716
Kendall B, Bellovary B, Gothe NP. Validity of wearable activity monitors for tracking steps and estimating energy expenditure during a graded maximal treadmill test. J Sports Sci. 2019;37:42–9.
pubmed: 29863968 doi: 10.1080/02640414.2018.1481723
Murakami H, Kawakami R, Nakae S, et al. Accuracy of 12 wearable devices for estimating physical activity energy expenditure using a metabolic chamber and the doubly labeled water method: validation study. JMIR Mhealth Uhealth. 2019;7:e13938.
pubmed: 31376273 pmcid: 6696858 doi: 10.2196/13938
O’Driscoll R, Turicchi J, Beaulieu K, et al. How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies. Br J Sports Med. 2020;54:332–40.
pubmed: 30194221
Fuller D, Colwell E, Low J, et al. Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: systematic review. JMIR Mhealth Uhealth. 2020;8:e18694.
pubmed: 32897239 pmcid: 7509623 doi: 10.2196/18694
Welk GJ, McClain J, Ainsworth BE. Protocols for evaluating equivalency of accelerometry-based activity monitors. Med Sci Sport Exerc. 2012;44(1 Suppl 1):S39-49.
doi: 10.1249/MSS.0b013e3182399d8f
Sperlich B, Holmberg H-C. Wearable, yes, but able…? It is time for evidence-based marketing claims! Br J Sports Med. 2017;51:1240.
pubmed: 27986762 doi: 10.1136/bjsports-2016-097295
Welk GJ, Bai Y, Lee J-M, et al. Standardizing analytic methods and reporting in activity monitor validation studies. Med Sci Sports Exerc. 2019;51:1767.
pubmed: 30913159 pmcid: 6693923 doi: 10.1249/MSS.0000000000001966
Keadle SK, Lyden KA, Strath SJ, et al. A framework to evaluate devices that assess physical behavior. Exerc Sport Sci Rev. 2019;47(4):206–14.
pubmed: 31524786 doi: 10.1249/JES.0000000000000206
Mühlen JM, Stang J, Skovgaard EL, et al. Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network. Br J Sports Med. 2012;55(14):767–79.
doi: 10.1136/bjsports-2020-103148
Johnston W, Judice PB, García PM, et al. Recommendations for determining the validity of consumer wearable and smartphone step count: expert statement and checklist of the INTERLIVE network. Br J Sports Med. 2021;55(14):780–93.
pubmed: 33361276 doi: 10.1136/bjsports-2020-103147
Bassett DR Jr, Rowlands AV, Trost SG. Calibration and validation of wearable monitors. Med Sci Sports Exerc. 2012;44:S32.
pubmed: 22157772 pmcid: 3273335 doi: 10.1249/MSS.0b013e3182399cf7
Freedson P, Bowles HR, Troiano R, et al. Assessment of physical activity using wearable monitors: recommendations for monitor calibration and use in the field. Med Sci Sport Exerc. 2012;44(1 Suppl 1):S1-4.
doi: 10.1249/MSS.0b013e3182399b7e
Veritas. Covidence Systematic Review Software. Veritas Health Innovation; 2021. www.covidence.org .
Fukagawa NK, Bandini LG, Young JB. Effect of age on body composition and resting metabolic rate. Am J Physiol Metab. 1990;259:E233–8.
Poehlman ET, Goran MI, Gardner AW, et al. Determinants of decline in resting metabolic rate in aging females. Am J Physiol Metab. 1993;264:E450–5.
Van Pelt RE, Jones PP, Davy KP, et al. Regular exercise and the age-related decline in resting metabolic rate in women. J Clin Endocrinol Metab. 1997;82:3208–12.
pubmed: 9329340
Arciero PJ, Goran MI, Poehlman ET. Resting metabolic rate is lower in women than in men. J Appl Physiol. 1993;75:2514–20.
pubmed: 8125870 doi: 10.1152/jappl.1993.75.6.2514
Fitzpatrick TB. The validity and practicality of sun-reactive skin types I through VI. Arch Dermatol. 1988;124:869–71.
pubmed: 3377516 doi: 10.1001/archderm.1988.01670060015008
Lu M-J, Zhong W-H, Liu Y-X, et al. Sample size for assessing agreement between two methods of measurement by Bland−Altman method. Int J Biostat. 2016. https://doi.org/10.1515/ijb-2015-0039 .
doi: 10.1515/ijb-2015-0039 pubmed: 27838682
Carstensen B. Comparing clinical measurement methods: a practical guide. New York: Wiley; 2011.
Butler PJ, Green JA, Boyd IL, et al. Measuring metabolic rate in the field: the pros and cons of the doubly labelled water and heart rate methods. Funct Ecol. 2004;18:168–83.
doi: 10.1111/j.0269-8463.2004.00821.x
Westerterp KR. Doubly labelled water assessment of energy expenditure: principle, practice, and promise. Eur J Appl Physiol. 2017;117:1277–85.
pubmed: 28508113 pmcid: 5486561 doi: 10.1007/s00421-017-3641-x
Davidsson L. Assessment of body composition and total energy expenditure in humans using stable isotope techniques. Vienna: International Atomic Energy Agency; 2009.
DeLany JP, Lovejoy JC. Energy expenditure. Endocrinol Metab Clin N Am. 1996;25:831–46.
doi: 10.1016/S0889-8529(05)70357-1
Delsoglio M, Achamrah N, Berger MM, et al. Indirect calorimetry in clinical practice. J Clin Med. 2019;8:1387.
pmcid: 6780066 doi: 10.3390/jcm8091387
Mtaweh H, Tuira L, Floh AA, et al. Indirect calorimetry: history, technology, and application. Front Pediatr. 2018;6:257.
pubmed: 30283765 pmcid: 6157446 doi: 10.3389/fped.2018.00257
Leonard WR. Laboratory and field methods for measuring human energy expenditure. Am J Hum Biol. 2012;24:372–84.
pubmed: 22419374 doi: 10.1002/ajhb.22260
Kinnunen H, Häkkinen K, Schumann M, et al. Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique. PLoS ONE. 2019;14:e0219563.
pubmed: 31291373 pmcid: 6619827 doi: 10.1371/journal.pone.0219563
Murakami H, Kawakami R, Nakae S, et al. Accuracy of wearable devices for estimating total energy expenditure: comparison with metabolic chamber and doubly labeled water method. JAMA Intern Med. 2016;176:702–3.
pubmed: 26999758 doi: 10.1001/jamainternmed.2016.0152
Ramirez-Marrero FA, Smith BA, Sherman WM, et al. Comparison of methods to estimate physical activity and energy expenditure in African American children. Int J Sport Med. 2005;26:363–71.
doi: 10.1055/s-2004-821011
Siddall A, Powell S, Needham-Beck S, et al. Validity of energy expenditure estimation methods during 10 days of military training. Scand J Med Sci Sport. 2019;29:1313–21.
doi: 10.1111/sms.13488
Dannecker K, Sazonova N, Melanson E, et al. A comparison of energy expenditure estimation of several physical activity monitors. Med Sci Sport Exerc. 2013;45:2105–12.
doi: 10.1249/MSS.0b013e318299d2eb
Evenson KR, Goto MM, Furberg RD. Systematic review of the validity and reliability of consumer-wearable activity trackers. Int J Behav Nutr Phys Act. 2015;12:1–22.
doi: 10.1186/s12966-015-0314-1
Montoye AHK, Mitrzyk JR, Molesky MJ. Comparative accuracy of a wrist-worn activity tracker and a smart shirt for physical activity assessment. Meas Phys Educ Exerc Sci. 2017;21:201–11.
doi: 10.1080/1091367X.2017.1331166
Kane NA, Simmons MC, John D, et al. Validity of the Nike plus device during walking and running. Int J Sport Med. 2010;31:101–5.
doi: 10.1055/s-0029-1242810
Nolan M, Mitchell J, Doyle-Baker P. Validity of the Apple iPhone®/iPod Touch® as an accelerometer-based physical activity monitor: a proof-of-concept study. J Phys Act Heal. 2014;11:759–69.
doi: 10.1123/jpah.2011-0336
Maddison R, Gemming L, Monedero J, et al. Quantifying Human Movement Using the Movn Smartphone App: Validation and Field Study. JMIR Mhealth Uhealth. 2017;5(8):e122.
pubmed: 28818819 pmcid: 5579324 doi: 10.2196/mhealth.7167
Xie J, Wen D, Liang L, et al. Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: comparative study. JMIR Mhealth Uhealth. 2018;6:e94.
pubmed: 29650506 pmcid: 5920198 doi: 10.2196/mhealth.9754
Johnson M, Turek J, Dornfeld C, et al. Validity of the Samsung Phone S Health application for assessing steps and energy expenditure during walking and running: Does phone placement matter? Digit Heal. 2016;2:2055207616652747.
Cui Y, Chipchase J, Ichikawa F. A cross culture study on phone carrying and physical personalization. In: International conference on usability and internationalization. Springer, Berlin; 2007. pp. 483–92.
Chowdhury E, Western M, Nightingale T, et al. Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors. PLoS ONE. 2017;12:e0171720.
pubmed: 28234979 pmcid: 5325221 doi: 10.1371/journal.pone.0171720
Thiebaud R, Funk M, Patton J, et al. Validity of wrist-worn consumer products to measure heart rate and energy expenditure. Digit Health. 2018;4:2055207618770322.
pubmed: 29942628 pmcid: 6001222
Adam Noah J, Spierer D, Gu J, et al. Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetry. J Med Eng Technol. 2013;37:456–62.
pubmed: 24007317 doi: 10.3109/03091902.2013.831135
Alsubheen S, George A, Baker A, et al. Accuracy of the vivofit activity tracker. J Med Eng Technol. 2016;40:298–306.
pubmed: 27266422 doi: 10.1080/03091902.2016.1193238
Machač S, Procházka M, Radvanský J, et al. Validation of physical activity monitors in individuals with diabetes: energy expenditure estimation by the multisensor SenseWear Armband Pro3 and the step counter Omron HJ-720 against indirect calorimetry during walking. Diabetes Technol Ther. 2013;15:413–8.
pubmed: 23557200 pmcid: 3643221 doi: 10.1089/dia.2012.0235
McArdle WD, Katch FI, Katch VL. Exercise physiology: nutrition, energy, and human performance. New York: Lippincott Williams & Wilkins; 2010.
McClave SA, Spain DA, Skolnick JL, et al. Achievement of steady state optimizes results when performing indirect calorimetry. J Parenter Enter Nutr. 2003;27:16–20.
doi: 10.1177/014860710302700116
Plowman SA, Smith DL. Exercise physiology for health fitness and performance. New York: Lippincott Williams & Wilkins; 2013.
Popp CJ, Tisch JJ, Sakarcan KE, et al. Approximate time to steady-state resting energy expenditure using indirect calorimetry in young, healthy adults. Front Nutr. 2016;3:49.
pubmed: 27857943 pmcid: 5093115 doi: 10.3389/fnut.2016.00049
Borges JH, Langer RD, Cirolini VX, et al. Minimum time to achieve the steady state and optimum abbreviated period to estimate the resting energy expenditure by indirect calorimetry in healthy young adults. Nutr Clin Pract. 2016;31:349–54.
pubmed: 26888859 doi: 10.1177/0884533615627268
Reeves MM, Davies PSW, Bauer J, et al. Reducing the time period of steady state does not affect the accuracy of energy expenditure measurements by indirect calorimetry. J Appl Physiol. 2004;97:130–4.
pubmed: 15020579 doi: 10.1152/japplphysiol.01212.2003
Jones AM, Doust JH. A 1% treadmill grade most accurately reflects the energetic cost of outdoor running. J Sports Sci. 1996;14:321–7.
pubmed: 8887211 doi: 10.1080/02640419608727717
Scott CB, Leighton BH, Ahearn KJ, et al. Aerobic, anaerobic, and excess postexercise oxygen consumption energy expenditure of muscular endurance and strength: 1-set of bench press to muscular fatigue. J Strength Cond Res. 2011;25:903–8.
pubmed: 20703175 doi: 10.1519/JSC.0b013e3181c6a128
Scott CB. Contribution of blood lactate to the energy expenditure of weight training. J Strength Cond Res. 2006;20:404.
pubmed: 16686572
Medbo JI, Mohn A-C, Tabata I, et al. Anaerobic capacity determined by maximal accumulated O2 deficit. J Appl Physiol. 1988;64:50–60.
pubmed: 3356666 doi: 10.1152/jappl.1988.64.1.50
Speakman J. Doubly labelled water: theory and practice. New York: Springer Science & Business Media; 1997.
Zaki R, Bulgiba A, Ismail R, et al. Statistical methods used to test for agreement of medical instruments measuring continuous variables in method comparison studies: a systematic review. PLoS ONE. 2012;7:e37908.
pubmed: 22662248 pmcid: 3360667 doi: 10.1371/journal.pone.0037908
Ludbrook J. Statistical techniques for comparing measurers and methods of measurement: a critical review. Clin Exp Pharmacol Physiol. 2002;29:527–36.
pubmed: 12060093 doi: 10.1046/j.1440-1681.2002.03686.x
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;327:307–10.
doi: 10.1016/S0140-6736(86)90837-8
De Myttenaere A, Golden B, Le Grand B, et al. Mean absolute percentage error for regression models. Neurocomputing. 2016;192:38–48.
doi: 10.1016/j.neucom.2015.12.114
Bennie JA, Shakespear-Druery J, De Cocker K. Muscle-strengthening Exercise Epidemiology: a New Frontier in Chronic Disease Prevention. Sport Med. 2020;6:1–8.
Ferro Magosso R, Campanholi Neto J, de Carli JPC, et al. A Review of Ergogenesis and Effect of Training Variables on Energy Expenditure in Resistance Training Exercises. J Exerc Physiol Online. 2017;20(2).
Scott C. Misconceptions about aerobic and anaerobic energy expenditure. J Int Soc Sports Nutr. 2005;2:1–6.
doi: 10.1186/1550-2783-2-2-32

Auteurs

Rob Argent (R)

Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland. rob.argent@insight-centre.org.
School of Public Health, Physiotherapy and Sport Science, University College Dublin, Dublin, Ireland. rob.argent@insight-centre.org.
School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland, Dublin, Ireland. rob.argent@insight-centre.org.

Megan Hetherington-Rauth (M)

Exercise and Health Laboratory, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal.

Julie Stang (J)

Department of Sport Medicine, Norwegian School of Sport Sciences, Oslo, Norway.

Jakob Tarp (J)

Department of Sport Medicine, Norwegian School of Sport Sciences, Oslo, Norway.

Francisco B Ortega (FB)

PROFITH (PROmoting FITness and Health Through Physical Activity) Research Group, Department of Physical Education and Sports, Faculty of Sport Sciences, University of Granada, Granada, Spain.
Department of Bioscience and Nutrition, Karolinska Institutet, Solna, Sweden.

Pablo Molina-Garcia (P)

PROFITH (PROmoting FITness and Health Through Physical Activity) Research Group, Department of Physical Education and Sports, Faculty of Sport Sciences, University of Granada, Granada, Spain.

Moritz Schumann (M)

Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University, Cologne, Germany.
Exercise Translational Medicine Centre, the Key Laboratory of Systems Biomedicine, Ministry of Education, and Exercise, Health and Technology Centre, Department of Physical Education, Shanghai Jiao Tong University, Shanghai, China.

Wilhelm Bloch (W)

Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University, Cologne, Germany.

Sulin Cheng (S)

Institute of Cardiovascular Research and Sports Medicine, Department of Molecular and Cellular Sports Medicine, German Sport University, Cologne, Germany.
Exercise Translational Medicine Centre, the Key Laboratory of Systems Biomedicine, Ministry of Education, and Exercise, Health and Technology Centre, Department of Physical Education, Shanghai Jiao Tong University, Shanghai, China.
Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland.

Anders Grøntved (A)

Department of Sports Science and Clinical Biomechanics, Research Unit for Exercise Epidemiology, Centre of Research in Childhood Health, University of Southern Denmark, Odense M, Denmark.

Jan Christian Brønd (JC)

Department of Sports Science and Clinical Biomechanics, Research Unit for Exercise Epidemiology, Centre of Research in Childhood Health, University of Southern Denmark, Odense M, Denmark.

Ulf Ekelund (U)

Department of Sport Medicine, Norwegian School of Sport Sciences, Oslo, Norway.

Luis B Sardinha (LB)

Exercise and Health Laboratory, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal.

Brian Caulfield (B)

Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.
School of Public Health, Physiotherapy and Sport Science, University College Dublin, Dublin, Ireland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH