Calibration of an underwater binocular vision system based on the refraction model.
Journal
Applied optics
ISSN: 1539-4522
Titre abrégé: Appl Opt
Pays: United States
ID NLM: 0247660
Informations de publication
Date de publication:
01 Mar 2022
01 Mar 2022
Historique:
entrez:
17
3
2022
pubmed:
18
3
2022
medline:
18
3
2022
Statut:
ppublish
Résumé
Underwater measurement based on stereo vision attaches great importance to camera calibration. However, it is challenging to perform accurate calibration due to the significant refraction presented at the interfaces of air and water. To solve this problem, a calibration method for an underwater binocular vision system based on the optimized refractive model is proposed. First, conventional calibration is performed to obtain basic initial camera parameters using checkerboard images collected in the air. Then, an evolutionary multi-objective function is established according to Snell's law, the refractive light propagation path, and checkerboard geometric relationship. Finally, precise camera parameters and involved refraction parameters are both obtained for underwater target positioning and size measurement by the non-dominated sorting genetic algorithm of the reference point. A group of experiments is performed, and the validity and effectiveness of the proposed calibration algorithm is demonstrated.
Identifiants
pubmed: 35297844
pii: 469792
doi: 10.1364/AO.448184
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM