Detecting Glaucoma in the Ocular Hypertension Study Using Deep Learning.
Journal
JAMA ophthalmology
ISSN: 2168-6173
Titre abrégé: JAMA Ophthalmol
Pays: United States
ID NLM: 101589539
Informations de publication
Date de publication:
01 04 2022
01 04 2022
Historique:
pubmed:
18
3
2022
medline:
26
4
2022
entrez:
17
3
2022
Statut:
ppublish
Résumé
Automated deep learning (DL) analyses of fundus photographs potentially can reduce the cost and improve the efficiency of reading center assessment of end points in clinical trials. To investigate the diagnostic accuracy of DL algorithms trained on fundus photographs from the Ocular Hypertension Treatment Study (OHTS) to detect primary open-angle glaucoma (POAG). In this diagnostic study, 1636 OHTS participants from 22 sites with a mean (range) follow-up of 10.7 (0-14.3) years. A total of 66 715 photographs from 3272 eyes were used to train and test a ResNet-50 model to detect the OHTS Endpoint Committee POAG determination based on optic disc (287 eyes, 3502 photographs) and/or visual field (198 eyes, 2300 visual fields) changes. Three independent test sets were used to evaluate the generalizability of the model. Areas under the receiver operating characteristic curve (AUROC) and sensitivities at fixed specificities were calculated to compare model performance. Evaluation of false-positive rates was used to determine whether the DL model detected POAG before the OHTS Endpoint Committee POAG determination. A total of 1147 participants were included in the training set (661 [57.6%] female; mean age, 57.2 years; 95% CI, 56.6-57.8), 167 in the validation set (97 [58.1%] female; mean age, 57.1 years; 95% CI, 55.6-58.7), and 322 in the test set (173 [53.7%] female; mean age, 57.2 years; 95% CI, 56.1-58.2). The DL model achieved an AUROC of 0.88 (95% CI, 0.82-0.92) for the OHTS Endpoint Committee determination of optic disc or VF changes. For the OHTS end points based on optic disc changes or visual field changes, AUROCs were 0.91 (95% CI, 0.88-0.94) and 0.86 (95% CI, 0.76-0.93), respectively. False-positive rates (at 90% specificity) were higher in photographs of eyes that later developed POAG by disc or visual field (27.5% [56 of 204]) compared with eyes that did not develop POAG (11.4% [50 of 440]) during follow-up. The diagnostic accuracy of the DL model developed on the optic disc end point applied to 3 independent data sets was lower, with AUROCs ranging from 0.74 (95% CI, 0.70-0.77) to 0.79 (95% CI, 0.78-0.81). The model's high diagnostic accuracy using OHTS photographs suggests that DL has the potential to standardize and automate POAG determination for clinical trials and management. In addition, the higher false-positive rate in early photographs of eyes that later developed POAG suggests that DL models detected POAG in some eyes earlier than the OHTS Endpoint Committee, reflecting the OHTS design that emphasized a high specificity for POAG determination by requiring a clinically significant change from baseline.
Identifiants
pubmed: 35297959
pii: 2790198
doi: 10.1001/jamaophthalmol.2022.0244
pmc: PMC8931672
doi:
Types de publication
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
383-391Subventions
Organisme : NEI NIH HHS
ID : UG1 EY025183
Pays : United States
Organisme : NEI NIH HHS
ID : R01 EY027510
Pays : United States
Organisme : NEI NIH HHS
ID : UG1 EY025181
Pays : United States
Organisme : NEI NIH HHS
ID : R21 EY027945
Pays : United States
Organisme : NEI NIH HHS
ID : R01 EY029058
Pays : United States
Organisme : NEI NIH HHS
ID : R01 EY026574
Pays : United States
Organisme : NEI NIH HHS
ID : K99 EY030942
Pays : United States
Organisme : NEI NIH HHS
ID : R01 EY019869
Pays : United States
Organisme : NEI NIH HHS
ID : UG1 EY025180
Pays : United States
Organisme : NEI NIH HHS
ID : UG1 EY025182
Pays : United States
Organisme : NEI NIH HHS
ID : R01 EY011008
Pays : United States