Feasibility of microvolumetric capillary whole blood collections for usage in Athlete Biological Passport analysis.
antidoping
biological passport
capillary blood
Journal
Drug testing and analysis
ISSN: 1942-7611
Titre abrégé: Drug Test Anal
Pays: England
ID NLM: 101483449
Informations de publication
Date de publication:
Jul 2022
Jul 2022
Historique:
revised:
04
03
2022
received:
04
02
2022
accepted:
10
03
2022
pubmed:
19
3
2022
medline:
16
7
2022
entrez:
18
3
2022
Statut:
ppublish
Résumé
The hematological module of the Athlete Biological Passport (ABP) represents an important tool in the pursuit to detect blood doping in athletes. Currently, collecting blood samples for ABP analysis can be cumbersome, invasive, and expensive, involving a venous blood draw performed by a trained phlebotomist followed by cold-chain monitored shipping to the analysis laboratory. Developing innovative methods to collect and transport ABP blood samples while adhering to strict preanalytical and analytical requirements has the potential to greatly increase testing frequency and, consequently, the effectiveness of the ABP program globally. The focus of this study was to compare venous blood collections with capillary blood collections to determine if capillary samples could be used for ABP analysis without sacrificing the analytical integrity required for antidoping testing procedures. In this study, capillary blood was collected using the Tasso+ EDTA device (Tasso, Inc.), a novel microvolumetric device that collects liquid, whole blood from skin capillaries on the upper arm. Excellent laboratory agreement was observed between venous and capillary blood samples for the three main ABP parameters: HGB, RET%, and OFF-Score. Additionally, the stability of capillary samples after storage at 4°C, similar to what would be required during transport, was acceptable for up to 72 h following collection. Finally, we generated individual ABP profiles using the adaptive model for 10 participants and observed excellent agreement between venous and capillary profiles. These results indicate capillary blood collection is a viable alternative to venous blood collections for ABP analysis.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1291-1299Informations de copyright
© 2022 John Wiley & Sons, Ltd.
Références
WADA Athlete Biological Passport (ABP) Operating Guidelines. 2021. [24 January 2022]; Available from: https://www.wada-ama.org/en/resources/world-anti-doping-program/athlete-biological-passport-abp-operating-guidelines
Daae LNW, Halvorsen S, Mathisen PM, Mironska K. A comparison between haemotological parameters in ‘capillary’ and venous blood from healthy adults. Scand J Clin Lab Invest. 1988;48(7):723-726. doi:10.3109/00365518809085796
Tasso, Inc. Tasso+ device instructions. 2022. [24 January 2022]; Available from: https://www.tassoinc.com/tasso-plus
WADA Technical Document-TDBAR2021. 2021. [24 January 2022]; Available from: https://www.wada-ama.org/en/resources/lab-documents/td2021bar
Zandecki M, Zandecki M, Genevieve F, Gerard J, Godon A. Spurious counts and spurious results on haematology analysers: a review. Part I: platelets. Int J Lab Hematol. 2007;29(1):4-20. doi:10.1111/j.1365-2257.2006.00870.x
Robinson N, Giraud S, Schumacher YO, Saugy M. Influence of transport and time on blood variable commonly measured for the Athlete Biological Passport. Drug Test Anal. 2016;8(2):199-207. doi:10.1002/dta.1804
Ashenden M, Sharpe K, Plowman J, et al. Stability of Athlete Biological Passport parameters during air freight. Int J Lab Hematol. 2013;36(5):505-513. doi:10.1111/ijlh.12178
Ashenden M, Clarke A, Sharpe K, d'Onofrio G, Plowman J, Gore CJ. Stability of athlete passport parameters during extended storage. Int J Lab Hematol. 2013;35(2):183-192. doi:10.1111/ijlh.12014