Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT.


Journal

Medical physics
ISSN: 2473-4209
Titre abrégé: Med Phys
Pays: United States
ID NLM: 0425746

Informations de publication

Date de publication:
Jun 2022
Historique:
revised: 23 02 2022
received: 07 10 2021
accepted: 23 02 2022
pubmed: 25 3 2022
medline: 11 6 2022
entrez: 24 3 2022
Statut: ppublish

Résumé

The accuracy of positron emission tomography (PET) quantification and localization can be compromised if a misregistered computed tomography (CT) is used for attenuation correction (AC) in PET/CT. As data-driven gating (DDG) continues to grow in clinical use, these issues are becoming more relevant with respect to solutions for gated CT. In this work, a new automated DDG CT method was developed to provide average CT and DDG CT for AC of PET and DDG PET, respectively. An automatic DDG CT was developed to provide the end-expiratory (EE) and end-inspiratory (EI) phases of images from low-dose cine CT images, with all phases being averaged to generate an average CT. The respiratory phases of EE and EI were determined according to lung region Hounsfield unit (HU) values and body outline contours. The average CT was used for AC of baseline PET and DDG CT at EE phase was used for AC of DDG PET at the quiescent or EE phase. The EI and EE phases obtained with DDG CT were used for assessing the magnitude of respiratory motion. The proposed DDG CT was compared to two commercial CT gating methods: (1) 4D CT (external device based) and (2) D4D CT (DDG based) in 38 patient datasets with respect to respiratory phase image selection, lung HU, lung volume, and image artifacts. In a separate set of twenty consecutive PET/CT studies containing a mix of In the EE phase, the images selected by DDG CT and 4D CT were identical 62.5% ± 21.6% of the time, whereas DDG CT and D4D CT were 6.5% ± 9.7%, and 4D CT and D4D CT were 8.6% ± 12.2%. These differences in EE phase image selection were significant (p < 0.0001). In the EI phase, the images selected by DDG CT and 4D CT were identical 68.2% ± 18.9% of the time, DDG CT and D4D CT were 63.9% ± 18.8%, and 4D CT and D4D CT were 61.2% ± 19.8%. These differences were not significant. The mean lung HU and volumes were not statistically different (p > 0.1) among the three methods. In some studies, DDG CT was better than D4D or 4D CT in the appropriate selection of the EE and EI phases, and D4D CT was found to reverse the EE and EI phases or not select the correct images by visual inspection. A statistically significant improvement of DDG CT over D4D CT for AC of DDG PET was also demonstrated with PET quantification analysis. When irregular breath cycles were present in the cine CT, DDG CT could be used to replace average CT for the improved AC of baseline PET. A new automatic DDG CT was developed to tackle the issues of misregistration and tumor motion in PET/CT imaging. DDG CT was significantly more consistent than D4D CT in selecting the EE phase images as the clinical standard of 4D CT. When compared to both commercial gated CT methods of 4D CT and D4D CT, DDG CT appeared to be more robust in the lower lung and upper diaphragm regions where misregistration and tumor motion often occur. DDG CT offered improved AC for DDG PET relative to D4D CT. In cases with irregular respiratory motion, DDG CT improved AC over average CT for baseline PET. The new DDG CT provides the benefits of 4D CT without the need for external device gating.

Sections du résumé

BACKGROUND BACKGROUND
The accuracy of positron emission tomography (PET) quantification and localization can be compromised if a misregistered computed tomography (CT) is used for attenuation correction (AC) in PET/CT. As data-driven gating (DDG) continues to grow in clinical use, these issues are becoming more relevant with respect to solutions for gated CT.
PURPOSE OBJECTIVE
In this work, a new automated DDG CT method was developed to provide average CT and DDG CT for AC of PET and DDG PET, respectively.
METHODS METHODS
An automatic DDG CT was developed to provide the end-expiratory (EE) and end-inspiratory (EI) phases of images from low-dose cine CT images, with all phases being averaged to generate an average CT. The respiratory phases of EE and EI were determined according to lung region Hounsfield unit (HU) values and body outline contours. The average CT was used for AC of baseline PET and DDG CT at EE phase was used for AC of DDG PET at the quiescent or EE phase. The EI and EE phases obtained with DDG CT were used for assessing the magnitude of respiratory motion. The proposed DDG CT was compared to two commercial CT gating methods: (1) 4D CT (external device based) and (2) D4D CT (DDG based) in 38 patient datasets with respect to respiratory phase image selection, lung HU, lung volume, and image artifacts. In a separate set of twenty consecutive PET/CT studies containing a mix of
RESULTS RESULTS
In the EE phase, the images selected by DDG CT and 4D CT were identical 62.5% ± 21.6% of the time, whereas DDG CT and D4D CT were 6.5% ± 9.7%, and 4D CT and D4D CT were 8.6% ± 12.2%. These differences in EE phase image selection were significant (p < 0.0001). In the EI phase, the images selected by DDG CT and 4D CT were identical 68.2% ± 18.9% of the time, DDG CT and D4D CT were 63.9% ± 18.8%, and 4D CT and D4D CT were 61.2% ± 19.8%. These differences were not significant. The mean lung HU and volumes were not statistically different (p > 0.1) among the three methods. In some studies, DDG CT was better than D4D or 4D CT in the appropriate selection of the EE and EI phases, and D4D CT was found to reverse the EE and EI phases or not select the correct images by visual inspection. A statistically significant improvement of DDG CT over D4D CT for AC of DDG PET was also demonstrated with PET quantification analysis. When irregular breath cycles were present in the cine CT, DDG CT could be used to replace average CT for the improved AC of baseline PET.
CONCLUSION CONCLUSIONS
A new automatic DDG CT was developed to tackle the issues of misregistration and tumor motion in PET/CT imaging. DDG CT was significantly more consistent than D4D CT in selecting the EE phase images as the clinical standard of 4D CT. When compared to both commercial gated CT methods of 4D CT and D4D CT, DDG CT appeared to be more robust in the lower lung and upper diaphragm regions where misregistration and tumor motion often occur. DDG CT offered improved AC for DDG PET relative to D4D CT. In cases with irregular respiratory motion, DDG CT improved AC over average CT for baseline PET. The new DDG CT provides the benefits of 4D CT without the need for external device gating.

Identifiants

pubmed: 35324002
doi: 10.1002/mp.15620
pmc: PMC9187617
mid: NIHMS1812548
doi:

Substances chimiques

copper dotatate CU-64 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

3597-3611

Subventions

Organisme : NCI NIH HHS
ID : R21 CA222749
Pays : United States
Organisme : NIBIB NIH HHS
ID : R03 EB030280
Pays : United States
Organisme : NHLBI NIH HHS
ID : R01 HL157273
Pays : United States
Organisme : NIH HHS
ID : R03-EB030280-01
Pays : United States
Organisme : NIH HHS
ID : R21-CA222749-01A1
Pays : United States
Organisme : NIH HHS
ID : R01-HL157273-01
Pays : United States

Informations de copyright

© 2022 American Association of Physicists in Medicine.

Références

Med Phys. 2015 Jul;42(7):4338-48
pubmed: 26133631
J Nucl Med. 2005 Apr;46(4):608-13
pubmed: 15809483
J Nucl Med. 2005 Sep;46(9):1481-7
pubmed: 16157531
Med Phys. 2020 Jun;47(6):2408-2412
pubmed: 32115724
Med Phys. 2005 Feb;32(2):627-34
pubmed: 15789609
Med Phys. 2004 Dec;31(12):3179-86
pubmed: 15651600
J Nucl Med. 2020 Sep;61(9):1376-1380
pubmed: 32005768
J Appl Clin Med Phys. 2012 Mar 08;13(2):3715
pubmed: 22402388
J Nucl Med. 2020 Oct;61(10):1520-1527
pubmed: 32060218
Phys Med Biol. 2015 Nov 21;60(22):8833-49
pubmed: 26531324
Cancer Imaging. 2011 Dec 28;11:224-36
pubmed: 22201582
Med Phys. 2004 Feb;31(2):333-40
pubmed: 15000619
Med Phys. 2006 Oct;33(10):3931-8
pubmed: 17089855
AJR Am J Roentgenol. 2009 Dec;193(6):1640-5
pubmed: 19933659
Pract Radiat Oncol. 2017 Sep - Oct;7(5):e345-e354
pubmed: 28341317
IEEE Trans Image Process. 2010 Jun;19(6):1596-609
pubmed: 20227983
Med Phys. 2003 Jun;30(6):1254-63
pubmed: 12852551
Med Phys. 2006 Sep;33(9):3116-23
pubmed: 17022203
J Nucl Med. 2020 Nov;61(11):1678-1683
pubmed: 32245898
Med Phys. 2007 Nov;34(11):4499-503
pubmed: 18072515
Acad Radiol. 2006 Sep;13(9):1082-92
pubmed: 16935720
Int J Radiat Oncol Biol Phys. 2021 Apr 1;109(5):1638-1646
pubmed: 33186619
IEEE Nucl Sci Symp Conf Rec (1997). 2010 Jan 29;2009(Oct. 24 2009-Nov. 1 2009):3074-3079
pubmed: 21373372
Med Phys. 2004 Jun;31(6):1333-8
pubmed: 15259636
Eur Radiol. 2020 Mar;30(3):1325-1333
pubmed: 31728688
Phys Med Biol. 2004 May 21;49(10):2053-67
pubmed: 15214541
EJNMMI Phys. 2021 Aug 28;8(1):64
pubmed: 34453630
Phys Med Biol. 2009 Aug 7;54(15):4821-33
pubmed: 19622855
Med Phys. 2008 Mar;35(3):917-26
pubmed: 18404928
J Nucl Med. 2018 Oct;59(10):1630-1635
pubmed: 29496982
J Am Geriatr Soc. 2013 Dec;61(12):2238-2240
pubmed: 24329828
Phys Med Biol. 2009 Apr 7;54(7):1935-50
pubmed: 19265207
J Nucl Med. 2018 Sep;59(9):1480-1486
pubmed: 29439015
IEEE Trans Med Imaging. 2018 May;37(5):1140-1148
pubmed: 29727277
Curr Radiol Rep. 2013 May 3;1:177-190
pubmed: 24883234
Phys Med Biol. 2009 Apr 7;54(7):2049-66
pubmed: 19287079

Auteurs

Tinsu Pan (T)

Department of Imaging Physics, M.D. Anderson Cancer Center, University of Texas, Houston, Texas, USA.

M Allan Thomas (MA)

Department of Imaging Physics, M.D. Anderson Cancer Center, University of Texas, Houston, Texas, USA.

Dershan Luo (D)

Department of Radiation Physics, M.D. Anderson Cancer Center, University of Texas, Houston, Texas, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH