Intraoperative Blood Flow Analysis of DIEP vs. ms-TRAM Flap Breast Reconstruction Combining Transit-Time Flowmetry and Microvascular Indocyanine Green Angiography.

autologous breast reconstruction flap imaging free tissue transfer indocyanine green angiography microsurgery perforator flaps transit-time flowmetry

Journal

Journal of personalized medicine
ISSN: 2075-4426
Titre abrégé: J Pers Med
Pays: Switzerland
ID NLM: 101602269

Informations de publication

Date de publication:
16 Mar 2022
Historique:
received: 27 01 2022
revised: 09 03 2022
accepted: 14 03 2022
entrez: 25 3 2022
pubmed: 26 3 2022
medline: 26 3 2022
Statut: epublish

Résumé

Background: Vascular patency is the key element for high flap survival rates. The purpose of this study was to assess and compare the blood flow characteristics of deep inferior epigastric perforator (DIEP) and muscle-sparing transverse rectus abdominis musculocutaneous (ms-TRAM) flaps for autologous breast reconstruction. Methods: This prospective clinical study combined Transit-Time Flowmetry and microvascular Indocyanine Green Angiography for the measurement of blood flow volume, vascular resistance, and intrinsic transit time. Results: Twenty female patients (mean age, 52 years) received 24 free flaps (14 DIEP and 10 ms-TRAM flaps). The mean arterial blood flow of the flap in situ was 7.2 ± 1.9 mL/min in DIEP flaps and 11.5 ± 4.8 mL/min in ms-TRAM flaps (p < 0.05). After anastomosis, the mean arterial blood flow was 9.7 ± 5.6 mL/min in DIEP flaps and 13.5 ± 4.2 mL/min in ms-TRAM flaps (p = 0.07). The arterial vascular resistance of DIEP flaps was significantly higher than that of ms-TRAM flaps. The intrinsic transit time of DIEP flaps was 52 ± 18 s, and that of ms-TRAM flaps was 33 ± 11 s (p < 0.05). The flap survival rate was 100%. One DIEP flap with the highest intrinsic transit time (77 s) required surgical revision due to arterial thrombosis. Conclusion: In this study, we established the blood flow characteristics of free DIEP and ms-TRAM flaps showing different blood flow rates, vascular resistances, and intrinsic transit times. These standard values will help to determine the predictive values for vascular compromise, hence improving the safety of autologous breast reconstruction procedures.

Identifiants

pubmed: 35330481
pii: jpm12030482
doi: 10.3390/jpm12030482
pmc: PMC8950170
pii:
doi:

Types de publication

Journal Article

Langues

eng

Références

Br J Oral Maxillofac Surg. 2017 Jul;55(6):628-630
pubmed: 28404211
Front Oncol. 2020 Mar 05;10:177
pubmed: 32195171
Ann Thorac Surg. 2000 Jul;70(1):212-7
pubmed: 10921710
J Craniomaxillofac Surg. 2018 Jun;46(6):905-915
pubmed: 29661662
Handchir Mikrochir Plast Chir. 2020 Apr;52(2):58-66
pubmed: 31863450
Microsurgery. 1995;16(10):666-72
pubmed: 8676729
Front Surg. 2019 Jul 02;6:39
pubmed: 31334246
Plast Reconstr Surg. 2005 May;115(6):1547-52
pubmed: 15861057
Microsurgery. 2009;29(7):509-14
pubmed: 19306390
Ann Chir Gynaecol. 1996;85(4):325-31
pubmed: 9014062
J Craniomaxillofac Surg. 2016 Nov;44(11):1833-1841
pubmed: 27745767
Plast Reconstr Surg. 2016 Sep;138(3):510e-518e
pubmed: 27556627
Sci Rep. 2019 Jul 24;9(1):10722
pubmed: 31341222
Ann Plast Surg. 2001 Aug;47(2):148-52
pubmed: 11506322
Plast Reconstr Surg. 2002 Aug;110(2):466-75; discussion 476-7
pubmed: 12142662
Methods Med Res. 1958;7:98-9
pubmed: 13516482
Br J Haematol. 2008 Oct;143(2):180-90
pubmed: 18783400
Breast. 2018 Apr;38:45-51
pubmed: 29227815
J Reconstr Microsurg. 2012 May;28(4):273-8
pubmed: 22492006
J Reconstr Microsurg. 1992 May;8(3):195-200
pubmed: 1629799
Eur J Vasc Endovasc Surg. 1996 Jul;12(1):91-6
pubmed: 8696905
Plast Reconstr Surg. 2000 Jan;105(1):55-61
pubmed: 10626970
Med Sci Monit. 2019 May 12;25:3520-3536
pubmed: 31079136
Perfusion. 2001 Nov;16(6):511-8
pubmed: 11761091
Plast Reconstr Surg. 2000 Jun;105(7):2395-9
pubmed: 10845292
J Plast Reconstr Aesthet Surg. 2013 Jan;66(1):73-9
pubmed: 23017936
Microsurgery. 2010;30(2):91-6
pubmed: 19790185
J Reconstr Microsurg. 2000 Feb;16(2):101-6
pubmed: 10706199
J Reconstr Microsurg. 2009 Jul;25(6):355-60
pubmed: 19396745
Eur J Cardiothorac Surg. 2000 Mar;17(3):287-93
pubmed: 10758390
Ann Plast Surg. 2005 Aug;55(2):117-21
pubmed: 16034237
Handchir Mikrochir Plast Chir. 2012 Apr;44(2):84-8
pubmed: 22495959
PLoS One. 2018 Oct 18;13(10):e0204077
pubmed: 30335754
Int Wound J. 2020 Feb;17(1):107-116
pubmed: 31668019
Plast Reconstr Surg. 2013 Feb;131(2):270-281
pubmed: 23076414
J Plast Reconstr Aesthet Surg. 2016 Oct;69(10):1382-8
pubmed: 27522453
Ann Plast Surg. 2001 Jun;46(6):590-3
pubmed: 11405356
J Plast Reconstr Aesthet Surg. 2020 Sep;73(9):1775-1784
pubmed: 32522517
Plast Reconstr Surg. 2020 Jul;146(1):1e-10e
pubmed: 32590635
J Reconstr Microsurg. 2009 Jan;25(1):39-45
pubmed: 18942044
J Craniomaxillofac Surg. 2015 Jun;43(5):643-8
pubmed: 25913628
J Reconstr Microsurg. 2001 Apr;17(3):163-7
pubmed: 11336147
J Reconstr Microsurg. 1997 Feb;13(2):125-30
pubmed: 9044187
Handchir Mikrochir Plast Chir. 2018 Aug;50(4):248-255
pubmed: 30130834
J Plast Reconstr Aesthet Surg. 2006;59(6):604-12; discussion 613
pubmed: 16716953

Auteurs

Alexander Geierlehner (A)

Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany.

Raymund E Horch (RE)

Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany.

Ingo Ludolph (I)

Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany.

Andreas Arkudas (A)

Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany.

Classifications MeSH