Comparison of the Beacon and Quark indirect calorimetry devices to measure resting energy expenditure in ventilated ICU patients.
Breath-by-breath analysis
Critically ill patients
Indirect calorimetry (IC)
Intensive care unit (ICU)
Mechanical ventilation
Resting energy expenditure (REE)
Journal
Clinical nutrition ESPEN
ISSN: 2405-4577
Titre abrégé: Clin Nutr ESPEN
Pays: England
ID NLM: 101654592
Informations de publication
Date de publication:
04 2022
04 2022
Historique:
received:
12
01
2022
accepted:
12
01
2022
entrez:
25
3
2022
pubmed:
26
3
2022
medline:
31
3
2022
Statut:
ppublish
Résumé
Critically ill patients in the Intensive Care Unit (ICU) should receive nutritional support matched to their metabolic needs as both under- and overfeeding energy has been shown to increase mortality. Critical illness can significantly affect metabolism. Consequently, resting energy expenditure (REE) can vary markedly during critical illness. Therefore, indirect calorimetry to estimate REE is recommended to determine energy requirements in individual ICU patients and to guide optimal nutritional support. Currently, the Quark metabolic monitor is considered the gold standard in our ICU, but novel mechanical support devices are also equipped with indirect calorimetry functionalities. This study aimed to evaluate the performance of a currently unevaluated device. A cross-sectional analysis in mechanically ventilated patients was conducted in a mixed medical-surgical ICU. The primary outcome was a numerical and visual comparison of the performance of the Beacon indirect calorimeter to calculate REE compared to the Quark device using Bland Altman plots. Performance was evaluated using bias, precision, accuracy, and reliability. Secondary analysis included a comparison with REE estimated by predictive equations. Seventy-one measurements were obtained in 27 mechanically ventilated subjects. An underestimation by the Beacon device in calculated REE of -96.2 kcal/day (4.5%) was found. There was a bias towards higher VCO Beacon indirect calorimetry accurately determined REE in mechanically ventilated critically ill patients compared to the gold standard in our ICU (Quark indirect calorimeter), although confidence intervals were wide. There was low bias and good reliability. On the other hand, predictive equations performed poorly compared to both devices, underestimating the true metabolic needs of mechanically ventilated ICU patients.
Identifiants
pubmed: 35331516
pii: S2405-4577(22)00026-2
doi: 10.1016/j.clnesp.2022.01.015
pii:
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
370-377Informations de copyright
Copyright © 2022 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest Prof. Dr A.R.H. van Zanten reported receiving honoraria for advisory board meetings, lectures, research, and travel expenses from AOP pharma, Braun, Cardinal Health, Danone-Nutricia, Dim-3, Fresenius Kabi, Mermaid, Lyric, and Nestle-Novartis. The other authors have nothing to declare.