A model-based approach for detecting and identifying faults on the D.C. side of a P.V. system using electrical signatures from I-V characteristics.
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2022
2022
Historique:
received:
06
07
2021
accepted:
16
11
2021
entrez:
29
3
2022
pubmed:
30
3
2022
medline:
30
3
2022
Statut:
epublish
Résumé
With the development of distributed generation and the corresponding importance of the P.V. (photovoltaic) system, it is desired to operate a P.V. system efficiently and reliably. To ensure such an operation, a monitoring system is required to diagnose the health of the system. This paper aims to analyze a P.V. system under various operating conditions to identify parameters-derived from the I-V (current-voltage) characteristics of the P.V. system-that could serve as electrical signatures to various faulty operations and facilitate in devising a monitoring algorithm for the system. A model-based approach has been adopted to represent a P.V. system, using a one-diode model of a practical P.V. cell, developed in MATLAB/Simulink. The modelled system comprises two arrays, while each array has two panels in series. It was simulated for various operating conditions: healthy condition represented by STC (Standard Testing Condition), O.C. (open-circuited), soiling, P.S. (partial-shading), H.S. (panels hotspots) and P.D. (panels degradation) conditions. For the analysis of I-V curves under these conditions, six derived parameters were selected: Vte (equivalent thermal voltage), MCPF (maximum current point factor), Ri (currents ratio), S (slope), and Dv and Di (voltages and currents differences, respectively). Using these parameters, data of the actual system under various conditions were compared with its model-generated data for healthy operating conditions. Thresholds were set for each parameter's value to mark normal operation range. It was observed that almost each considered fault creates a unique combination of sensitive parameters whose values exceeds the pre-defined thresholds, creating an electrical signature that will appear only when the corresponding conditions on the system are achieved. Based on these signatures, an algorithm has been proposed in this study which aims to identify and classify the considered faults. In comparison to other such studies, this work has been focused on those sensitive parameters for faults identification which shows greater sensitivity and contribute more to creation of unique sets of sensitive parameters for considered faults.
Identifiants
pubmed: 35349570
doi: 10.1371/journal.pone.0260771
pii: PONE-D-21-20995
pmc: PMC8963553
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0260771Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.