Disease-specific assessment of Vision Impairment in Low Luminance in age-related macular degeneration - a MACUSTAR study report.
Diagnostic tests/Investigation
Macula
Journal
The British journal of ophthalmology
ISSN: 1468-2079
Titre abrégé: Br J Ophthalmol
Pays: England
ID NLM: 0421041
Informations de publication
Date de publication:
08 2023
08 2023
Historique:
received:
25
11
2021
accepted:
07
03
2022
medline:
21
8
2023
pubmed:
1
4
2022
entrez:
31
3
2022
Statut:
ppublish
Résumé
To further validate the Vision Impairment in Low Luminance (VILL) questionnaire, which captures visual functioning and vision-related quality of life (VRQoL) under low luminance, low-contrast conditions relevant to age-related macular degeneration (AMD). The VILL was translated from German into English (UK), Danish, Dutch, French, Italian and Portuguese. Rasch analysis was used to assess psychometric characteristics of 716 participants (65% female, mean age 72±7 years, 82% intermediate AMD) from the baseline visit of the MACUSTAR study. In a subset of participants (n=301), test-retest reliability (intraclass correlation coefficient (ICC) and coefficient of repeatability (CoR)) and construct validity were assessed. Four items were removed from the VILL with 37 items due to misfit. The resulting Vision Impairment in Low Luminance with 33 items (VILL-33) has three subscales with no disordered thresholds and no misfitting items. No differential item functioning and no multidimensionality were observed. Person reliability and person separation index were 0.91 and 3.27 for the Vision Impairment in Low Luminance Reading Subscale (VILL-R), 0.87 and 2.58 for the Vision Impairment in Low Luminance Mobility Subscale (VILL-M), and 0.78 and 1.90 for the Vision Impairment in Low Luminance Emotional Subscale (VILL-E). ICC and CoR were 0.92 and 1.9 for VILL-R, 0.93 and 1.8 for VILL-M and 0.82 and 5.0 for VILL-E. Reported VRQoL decreased with advanced AMD stage (p<0.0001) and was lower in the intermediate AMD group than in the no AMD group (p≤0.0053). The VILL is a psychometrically sound patient-reported outcome instrument, and the results further support its reliability and validity across all AMD stages. We recommend the shortened version of the questionnaire with three subscales (VILL-33) for future use. NCT03349801.
Sections du résumé
BACKGROUND/AIMS
To further validate the Vision Impairment in Low Luminance (VILL) questionnaire, which captures visual functioning and vision-related quality of life (VRQoL) under low luminance, low-contrast conditions relevant to age-related macular degeneration (AMD).
METHODS
The VILL was translated from German into English (UK), Danish, Dutch, French, Italian and Portuguese. Rasch analysis was used to assess psychometric characteristics of 716 participants (65% female, mean age 72±7 years, 82% intermediate AMD) from the baseline visit of the MACUSTAR study. In a subset of participants (n=301), test-retest reliability (intraclass correlation coefficient (ICC) and coefficient of repeatability (CoR)) and construct validity were assessed.
RESULTS
Four items were removed from the VILL with 37 items due to misfit. The resulting Vision Impairment in Low Luminance with 33 items (VILL-33) has three subscales with no disordered thresholds and no misfitting items. No differential item functioning and no multidimensionality were observed. Person reliability and person separation index were 0.91 and 3.27 for the Vision Impairment in Low Luminance Reading Subscale (VILL-R), 0.87 and 2.58 for the Vision Impairment in Low Luminance Mobility Subscale (VILL-M), and 0.78 and 1.90 for the Vision Impairment in Low Luminance Emotional Subscale (VILL-E). ICC and CoR were 0.92 and 1.9 for VILL-R, 0.93 and 1.8 for VILL-M and 0.82 and 5.0 for VILL-E. Reported VRQoL decreased with advanced AMD stage (p<0.0001) and was lower in the intermediate AMD group than in the no AMD group (p≤0.0053).
CONCLUSION
The VILL is a psychometrically sound patient-reported outcome instrument, and the results further support its reliability and validity across all AMD stages. We recommend the shortened version of the questionnaire with three subscales (VILL-33) for future use.
TRIAL REGISTRATION NUMBER
NCT03349801.
Identifiants
pubmed: 35354561
pii: bjophthalmol-2021-320848
doi: 10.1136/bjophthalmol-2021-320848
pmc: PMC10359508
doi:
Banques de données
ClinicalTrials.gov
['NCT03349801']
Types de publication
Clinical Trial
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1144-1150Investigateurs
H Agostini
(H)
L Altay
(L)
R Atia
(R)
F Bandello
(F)
P G Basile
(PG)
C Behning
(C)
M Belmouhand
(M)
M Berger
(M)
A Binns
(A)
C J F Boon
(CJF)
M Böttger
(M)
C Bouchet
(C)
J E Brazier
(JE)
T Butt
(T)
C Carapezzi
(C)
J Carlton
(J)
A Carneiro
(A)
A Charil
(A)
R Coimbra
(R)
M Cozzi
(M)
D P Crabb
(DP)
J Cunha-Vaz
(J)
C Dahlke
(C)
L de Sisternes
(L)
H Dunbar
(H)
R P Finger
(RP)
E Fletcher
(E)
H Floyd
(H)
C Francisco
(C)
M Gutfleisch
(M)
R Hogg
(R)
F G Holz
(FG)
C B Hoyng
(CB)
A Kilani
(A)
J Krätzschmar
(J)
L Kühlewein
(L)
M Larsen
(M)
S Leal
(S)
Y T E Lechanteur
(YTE)
U F O Luhmann
(UFO)
A Lüning
(A)
I Marques
(I)
C Martinho
(C)
G Montesano
(G)
Z Mulyukov
(Z)
M Paques
(M)
B Parodi
(B)
M Parravano
(M)
S Penas
(S)
T Peters
(T)
T Peto
(T)
M Pfau
(M)
S Poor
(S)
S Priglinger
(S)
D Rowen
(D)
G S Rubin
(GS)
J Sahel
(J)
D Sanches Fernandes
(D)
C Sánchez
(C)
O Sander
(O)
M Saßmannshausen
(M)
M Schmid
(M)
S Schmitz-Valckenberg
(S)
H Schrinner-Fenske
(H)
J Siedlecki
(J)
R Silva
(R)
A Skelly
(A)
E Souied
(E)
G Staurenghi
(G)
L Stöhr
(L)
D Tavares
(D)
J Tavares
(J)
D J Taylor
(DJ)
J H Terheyden
(JH)
S Thiele
(S)
A Tufail
(A)
M Varano
(M)
L Vieweg
(L)
J Werner
(J)
L Wintergerst
(L)
A Wolf
(A)
N Zakaria
(N)
Informations de copyright
© Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY. Published by BMJ.
Déclaration de conflit d'intérêts
Competing interests: JHT: Heidelberg Engineering, Optos, Carl Zeiss Meditec, CenterVueSGP: Heidelberg Engineering, Optos Carl Zeiss Meditec, CenterVue; CBe: None; MB: None; JC: None; DR: None; CBo: employee of Novartis; SP: employee of Novartis; UFOL: employee of F. Hoffmann-La Roche; SL: employee of Bayer; FGH: Acucela, Allergan, Apellis, Bayer, Boehringer-Ingelheim, Bioeq/Formycon, CenterVue, Ellex, Roche/Genentech, Geuder, Grayburg Vision, Heidelberg Engineering, Kanghong, LinBioscience, NightStarX, Novartis, Optos, Pixium Vision, Oxurion, Stealth BioTherapeutics, Zeiss; TB: None; JB: None; RPF: Bayer, Ellex, Novartis, Novartis, Opthea, Alimera, Santhera, Roche/Genentech, CentreVue, Zeiss.
Références
Am J Ophthalmol. 2018 May;189:127-138
pubmed: 29477964
Value Health. 2004 Sep-Oct;7 Suppl 1:S22-6
pubmed: 15367240
Ophthalmology. 2013 Apr;120(4):844-51
pubmed: 23332590
Trials. 2020 Jul 18;21(1):659
pubmed: 32682441
Ophthalmologica. 2019;241(2):61-72
pubmed: 30153664
BMJ. 1992 Jul 18;305(6846):160-4
pubmed: 1285753
Ophthalmology. 2008 Nov;115(11):1876-82
pubmed: 18672295
Transl Vis Sci Technol. 2019 Sep 11;8(5):3
pubmed: 31588369
Retina. 2016 May;36(5):1021-31
pubmed: 26925551
Sci Rep. 2019 Oct 25;9(1):15326
pubmed: 31653904
Invest Ophthalmol Vis Sci. 2011 Dec 09;52(13):9457-69
pubmed: 22003115
Invest Ophthalmol Vis Sci. 2017 Jul 1;58(9):3456-3463
pubmed: 28702674
Health Qual Life Outcomes. 2006 Oct 11;4:79
pubmed: 17034633
Invest Ophthalmol Vis Sci. 2011 Oct 17;52(11):8241-9
pubmed: 21908584
Optom Vis Sci. 2013 Aug;90(8):720-44
pubmed: 23873034
Lancet. 1986 Feb 8;1(8476):307-10
pubmed: 2868172
Ophthalmology. 2016 May;123(5):1060-79
pubmed: 26952592
Am J Ment Defic. 1981 Sep;86(2):127-37
pubmed: 7315877
Value Health. 2005 Mar-Apr;8(2):94-104
pubmed: 15804318
Invest Ophthalmol Vis Sci. 2006 Feb;47(2):528-35
pubmed: 16431946
Optom Vis Sci. 2014 Aug;91(8):916-24
pubmed: 24978867
J Appl Meas. 2002;3(2):205-31
pubmed: 12011501
Med Care. 2000 Sep;38(9 Suppl):II28-42
pubmed: 10982088
Ophthalmologica. 2021;244(5):387-395
pubmed: 33285549
J Clin Epidemiol. 2009 Mar;62(3):288-95
pubmed: 18774693
Ophthalmology. 2019 Jun;126(6):829-838
pubmed: 30244144
Ophthalmology. 2014 Aug;121(8):1612-9
pubmed: 24661863
Transl Vis Sci Technol. 2021 Jan 06;10(1):5
pubmed: 33505772
J Clin Epidemiol. 2003 Aug;56(8):730-5
pubmed: 12954464
J Outcome Meas. 1998;2(3):266-83
pubmed: 9711024
Ophthalmic Physiol Opt. 2016 Jul;36(4):465-76
pubmed: 27350185