Revision and Replacement of Spinal Cord Stimulator Paddle Leads.


Journal

Neuromodulation : journal of the International Neuromodulation Society
ISSN: 1525-1403
Titre abrégé: Neuromodulation
Pays: United States
ID NLM: 9804159

Informations de publication

Date de publication:
Jul 2022
Historique:
received: 04 12 2021
revised: 09 02 2022
accepted: 23 02 2022
pubmed: 9 4 2022
medline: 14 7 2022
entrez: 8 4 2022
Statut: ppublish

Résumé

Paddle leads for spinal cord stimulation (SCS) offer more efficient energy delivery and advantages in some patients. However, there is concern for how safely SCS paddles can be replaced once previously implanted because of scar tissue and the relative vulnerability of the thoracic cord. In this study, we share our experience on SCS paddle replacement. Participants who underwent SCS replacement at Albany Medical Center between 2011 and 2020 were identified. The medical records were reviewed for demographic data and information regarding initial complications, reason for removal or revision, subsequent complications of replacement surgery and its timing, and whether the implant was ultimately removed. Percutaneous lead replacement cases performed over the same period were used as a comparison group. A total of 1265 patients were identified to have had an SCS-related procedure based on billing codes. Of these, 73 involved replacement of epidural leads (51 paddles, 22 percutaneous). Most paddles (48/51) were replaced at the time of removal. A total of 30 of the 51 paddle replacements required additional lamina removal. Re-operations that occurred more than one year after initial implant were significantly more likely to require additional bone removal (p < 0.001). Paddle re-operations lasted in general 1.7 ± 0.2 hours and had 35 ± 5 mL of blood loss, whereas percutaneous operations lasted 1.3 ± 0.2 hours and had 12.5 ± 2 mL of blood loss. Despite the invasive nature of paddle replacement, there was no difference in complications (p = 0.23) compared with that in percutaneous leads. This study characterizes the safety profile of SCS paddle replacement surgeries. Here, we demonstrate that the replacement of paddle leads at the time of removal, with additional lamina removal if needed because of scar, is associated with low rates of complications. This validates the feasibility and low-risk profile of replacing paddle leads when clinically indicated for experienced surgeons with specialization in SCS.

Identifiants

pubmed: 35393239
pii: S1094-7159(22)00558-X
doi: 10.1016/j.neurom.2022.02.228
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

753-757

Informations de copyright

Copyright © 2022 International Neuromodulation Society. Published by Elsevier Inc. All rights reserved.

Auteurs

Tessa A Harland (TA)

Department of Neurosurgery, Albany Medical College, Albany, NY, USA.

Gregory Topp (G)

Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, NY, USA.

Kevin Shao (K)

Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, NY, USA.

Julie G Pilitsis (JG)

Department of Neurosurgery, Albany Medical College, Albany, NY, USA; Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, NY, USA. Electronic address: jpilitsis@yahoo.com.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH