Résumé
Magnetic resonance imaging (MRI) is a noninvasive technique that provides excellent contrast for soft tissue organs. However, due to the low density of protons and many air-tissue junctions, its application in the lung is limited. Thus, X‑ray-based methods are often used here (with the well-known disadvantages of ionizing radiation). In this review, we discuss pulmonary MRI with hyperpolarized xenon-129 (Xe-MRI). Xe-MRI provides unique valuable insights into lung microstructure and function, including gas exchange with red blood cells-parameters not accessible by any standard clinical methods. By magnetic labelling, i.e. hyperpolarization, the signal from xenon-129 is amplified by up to 100,000 times. In this process, electrons from rubidium are first polarized to 100% using laser light and then transferred to xenon by collisions. Then the hyperpolarized gas is brought to the patient in a bag and inhaled shortly before the MRI scan. Using special programming (sequences) of the MRI, the ventilation, microstructure, or gas exchange of the lungs, can be displayed in 3D. This allows, for example, quantitative visualization of ventilation defects, alveolar size, tissue gas uptake and gas transfer to the blood. Xe-MRI provides unique information about the state of the lung-noninvasively, in vivo and in less than a minute. HINTERGRUND: Die Magnetresonanztomographie (MRT) ist ein nichtinvasives Verfahren mit hervorragendem Weichteilkontrast. Aufgrund der geringen Protonendichte und vielen Luft-Gewebe-Übergängen ist die Anwendung in der Lunge jedoch eingeschränkt, so dass hier häufig röntgenbasierte Methoden eingesetzt werden (mit den bekannten Nachteilen ionisierender Strahlung). In dieser Übersichtsarbeit wird die Lungen-MRT mit hyperpolarisiertem Xenon-129 (Xe-MRT) dargestellt. Die Xe-MRT erlaubt einzigartige wertvolle Einblicke in die Mikrostruktur und Funktion der Lunge, einschließlich des Gasaustauschs mit roten Blutkörperchen – Parameter, die mit klinischen Standardmethoden nicht zugänglich sind. Durch die magnetische Markierung, die Hyperpolarisierung, wird das Signal von Xenon-129 um bis zu 100.000-fach verstärkt. Hierbei werden die Elektronen von Rubidium mittels Laserlicht zunächst auf 100 % polarisiert und dann durch Stöße auf Xenon übertragen. Danach wird das hyperpolarisierte Gas in einem Beutel zum Patienten gebracht und eingeatmet, kurz bevor die MRT-Aufnahmen beginnen. Durch spezielle Programmierungen (Sequenzen) in der MRT kann die Ventilation, Mikrostruktur oder der Gasaustausch der Lunge in 3‑D dargestellt werden. Dies ermöglicht z. B. die quantitative Darstellung von Belüftungsdefekten, der Größe der Alveolen, der Gasaufnahme im Gewebe und des Gastransfers ins Blut. Die Xe-MRT liefert einzigartige Informationen über den Zustand der Lunge – nichtinvasiv, in vivo und in weniger als einer Minute.
Sections du résumé
BACKGROUND
BACKGROUND
Magnetic resonance imaging (MRI) is a noninvasive technique that provides excellent contrast for soft tissue organs. However, due to the low density of protons and many air-tissue junctions, its application in the lung is limited. Thus, X‑ray-based methods are often used here (with the well-known disadvantages of ionizing radiation).
OBJECTIVES
OBJECTIVE
In this review, we discuss pulmonary MRI with hyperpolarized xenon-129 (Xe-MRI). Xe-MRI provides unique valuable insights into lung microstructure and function, including gas exchange with red blood cells-parameters not accessible by any standard clinical methods.
METHODS
METHODS
By magnetic labelling, i.e. hyperpolarization, the signal from xenon-129 is amplified by up to 100,000 times. In this process, electrons from rubidium are first polarized to 100% using laser light and then transferred to xenon by collisions. Then the hyperpolarized gas is brought to the patient in a bag and inhaled shortly before the MRI scan.
RESULTS
RESULTS
Using special programming (sequences) of the MRI, the ventilation, microstructure, or gas exchange of the lungs, can be displayed in 3D. This allows, for example, quantitative visualization of ventilation defects, alveolar size, tissue gas uptake and gas transfer to the blood.
CONCLUSIONS
CONCLUSIONS
Xe-MRI provides unique information about the state of the lung-noninvasively, in vivo and in less than a minute.
ZUSAMMENFASSUNG
UNASSIGNED
HINTERGRUND: Die Magnetresonanztomographie (MRT) ist ein nichtinvasives Verfahren mit hervorragendem Weichteilkontrast. Aufgrund der geringen Protonendichte und vielen Luft-Gewebe-Übergängen ist die Anwendung in der Lunge jedoch eingeschränkt, so dass hier häufig röntgenbasierte Methoden eingesetzt werden (mit den bekannten Nachteilen ionisierender Strahlung).
FRAGESTELLUNG
UNASSIGNED
In dieser Übersichtsarbeit wird die Lungen-MRT mit hyperpolarisiertem Xenon-129 (Xe-MRT) dargestellt. Die Xe-MRT erlaubt einzigartige wertvolle Einblicke in die Mikrostruktur und Funktion der Lunge, einschließlich des Gasaustauschs mit roten Blutkörperchen – Parameter, die mit klinischen Standardmethoden nicht zugänglich sind.
MATERIAL UND METHODEN
METHODS
Durch die magnetische Markierung, die Hyperpolarisierung, wird das Signal von Xenon-129 um bis zu 100.000-fach verstärkt. Hierbei werden die Elektronen von Rubidium mittels Laserlicht zunächst auf 100 % polarisiert und dann durch Stöße auf Xenon übertragen. Danach wird das hyperpolarisierte Gas in einem Beutel zum Patienten gebracht und eingeatmet, kurz bevor die MRT-Aufnahmen beginnen.
ERGEBNISSE
UNASSIGNED
Durch spezielle Programmierungen (Sequenzen) in der MRT kann die Ventilation, Mikrostruktur oder der Gasaustausch der Lunge in 3‑D dargestellt werden. Dies ermöglicht z. B. die quantitative Darstellung von Belüftungsdefekten, der Größe der Alveolen, der Gasaufnahme im Gewebe und des Gastransfers ins Blut.
SCHLUSSFOLGERUNG
UNASSIGNED
Die Xe-MRT liefert einzigartige Informationen über den Zustand der Lunge – nichtinvasiv, in vivo und in weniger als einer Minute.
Autres résumés
Type: Publisher
(ger)
HINTERGRUND: Die Magnetresonanztomographie (MRT) ist ein nichtinvasives Verfahren mit hervorragendem Weichteilkontrast. Aufgrund der geringen Protonendichte und vielen Luft-Gewebe-Übergängen ist die Anwendung in der Lunge jedoch eingeschränkt, so dass hier häufig röntgenbasierte Methoden eingesetzt werden (mit den bekannten Nachteilen ionisierender Strahlung).
Identifiants
pubmed: 35403905
doi: 10.1007/s00117-022-00993-w
pii: 10.1007/s00117-022-00993-w
pmc: PMC8996207
doi:
Substances chimiques
Xenon
3H3U766W84
Types de publication
Journal Article
Review
Langues
ger
Sous-ensembles de citation
IM
Pagination
475-485Informations de copyright
© 2022. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.
Références
Voskrebenzev A, Gutberlet M, Klimeš F, Kaireit TF, Schönfeld C, Rotärmel A et al (2018) Feasibility of quantitative regional ventilation and perfusion mapping with phase-resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. Magn Reson Med 79(4):2306–2314
pubmed: 28856715
doi: 10.1002/mrm.26893
Renz DM, Herrmann K‑H, Kraemer M, Boettcher J, Waginger M, Krueger P‑C et al (2022) Ultrashort echo time MRI of the lung in children and adolescents: comparison with non-enhanced computed tomography and standard post-contrast T1w MRI sequences. Eur Radiol 32:1833–1842. https://doi.org/10.1007/s00330-021-08236-7
doi: 10.1007/s00330-021-08236-7
pubmed: 34668994
Ebert M, Grossmann T, Heil W, Otten EW, Surkau R, Thelen M et al (1996) Nuclear magnetic resonance imaging with hyperpolarised helium‑3. Lancet 347(9011):1297–1299
pubmed: 8622506
doi: 10.1016/S0140-6736(96)90940-X
Mugler JP, Driehuys B, Brookeman JR, Cates GD, Berr SS, Bryant RG et al (1997) MR imaging and spectroscopy using hyperpolarized129Xe gas: Preliminary human results. Magn Reson Med 37(6):809–815
pubmed: 9178229
doi: 10.1002/mrm.1910370602
Buzan MTA, Eichinger M, Kreuter M, Kauczor H‑U, Herth FJ, Warth A et al (2015) T2 mapping of CT remodelling patterns in interstitial lung disease. Eur Radiol 25(11):3167–3174
pubmed: 26037715
doi: 10.1007/s00330-015-3751-y
Zapp J, Domsch S, Weingärtner S, Schad LR (2017) Gaussian signal relaxation around spin echoes: implications for precise reversible transverse relaxation quantification of pulmonary tissue at 1.5 and 3 tesla. Magn Reson Med 77(5):1938–1945
pubmed: 27343149
doi: 10.1002/mrm.26280
Heye T, Sommer G, Miedinger D, Bremerich J, Bieri O (2015) Ultrafast 3D balanced steady-state free precession MRI of the lung: assessment of anatomic details in comparison to low-dose CT: Ultrafast 3D bSSFP MRI of the lung. J Magn Reson Imaging 42(3):602–609
pubmed: 25545835
doi: 10.1002/jmri.24836
Bauman G, Pusterla O, Bieri O (2019) Functional lung imaging with transient spoiled gradient echo. Magn Reson Med 81(3):1915–1923
pubmed: 30346077
doi: 10.1002/mrm.27535
Nichols MB, Paschal CB (2008) Measurement of longitudinal (T1) relaxation in the human lung at 3.0 Tesla with tissue-based and regional gradient analyses. J Magn Reson Imaging 27(1):224–228
pubmed: 18058926
doi: 10.1002/jmri.21243
Puderbach M, Eichinger M, Gahr J, Ley S, Tuengerthal S, Schmähl A et al (2007) Proton MRI appearance of cystic fibrosis: comparison to CT. Eur Radiol 17(3):716–724
pubmed: 16941092
doi: 10.1007/s00330-006-0373-4
Roach DJ, Crémillieux Y, Fleck RJ, Brody AS, Serai SD, Szczesniak RD et al (2016) Ultrashort echo-time magnetic resonance imaging is a sensitive method for the evaluation of early cystic fibrosis lung disease. Annals ATS 13(11):1923–1931
doi: 10.1513/AnnalsATS.201603-203OC
Pusterla O, Bauman G, Bieri O (2018) Three-dimensional oxygen-enhanced MRI of the human lung at 1.5T with ultra-fast balanced steady-state free precession: 3D OE-MRI With ufSSFP. Magn Reson Med 79(1):246–255
pubmed: 28337782
doi: 10.1002/mrm.26665
Couch MJ, Ball IK, Li T, Fox MS, Biman B, Albert MS (2019)
pubmed: 30248212
doi: 10.1002/jmri.26292
Kovtunov KV, Pokochueva EV, Salnikov OG, Cousin SF, Kurzbach D, Vuichoud B et al (2018) Hyperpolarized NMR spectroscopy: d‑DNP, PHIP, and SABRE techniques. Chem Asian J 13(15):1857–1871
doi: 10.1002/asia.201800551
Mugler JP, Altes TA (2013) Hyperpolarized
pubmed: 23355432
pmcid: 3558952
doi: 10.1002/jmri.23844
Wild JM, Schmiedeskamp J, Paley MNJ, Filbir F, Fichele S, Kasuboski L et al (2002) MR imaging of the lungs with hyperpolarized helium‑3 gas transported by air. Phys Med Biol 47(13):N185–N190
pubmed: 12164592
doi: 10.1088/0031-9155/47/13/401
Nikolaou P, Coffey AM, Walkup LL, Gust BM, Whiting N, Newton H et al (2013) Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI. Proc Natl Acad Sci U S A 110(35):14150–14155
pubmed: 23946420
pmcid: 3761567
doi: 10.1073/pnas.1306586110
Leawoods JC, Yablonskiy DA, Saam B, Gierada DS, Conradi MS (2001) Hyperpolarized3He gas production and MR imaging of the lung. Concepts Magn Reson 13(5):277–293
doi: 10.1002/cmr.1014
Chan H‑F, Collier GJ, Weatherley ND, Wild JM (2019) Comparison of in vivo lung morphometry models from 3D multiple b‑value
pubmed: 30515852
doi: 10.1002/mrm.27608
Hersman FW, Ruset IC, Ketel S, Muradian I, Covrig SD, Distelbrink J et al (2008) Large production system for hyperpolarized 129Xe for human lung imaging studies. Acad Radiol 15(6):683–692
pubmed: 18486005
pmcid: 2475596
doi: 10.1016/j.acra.2007.09.020
Plummer JW, Emami K, Dummer A, Woods JC, Walkup LL, Cleveland ZI (2020) A semi-empirical model to optimize continuous-flow hyperpolarized 129Xe production under practical cryogenic-accumulation conditions. J Magn Reson 320:106845
pubmed: 33070086
pmcid: 7655637
doi: 10.1016/j.jmr.2020.106845
Birchall JR, Irwin RK, Nikolaou P, Pokochueva EV, Kovtunov KV, Koptyug IV et al (2020) Pilot multi-site quality assurance study of batch-mode clinical-scale automated xenon-129 hyperpolarizers. J Magn Reson 316:106755
pubmed: 32512397
doi: 10.1016/j.jmr.2020.106755
Norquay G, Collier GJ, Rodgers OI, Gill AB, Screaton NJ, Wild J (2022) Standalone portable xenon-129 hyperpolariser for multicentre clinical magnetic resonance imaging of the lungs. BJR 31:20210872
doi: 10.1259/bjr.20210872
Khan AS, Harvey RL, Birchall JR, Irwin RK, Nikolaou P, Schrank G et al (2021) Enabling clinical technologies for hyperpolarized
doi: 10.1002/anie.202015200
Oxford BRC Xenon MRI research programme – groundbreaking lung imaging (2015). https://youtu.be/dv3xRWU8_qc
Shukla Y, Wheatley A, Kirby M, Svenningsen S, Farag A, Santyr GE et al (2012) Hyperpolarized 129Xe magnetic resonance imaging. Acad Radiol 19(8):941–951
pubmed: 22591724
doi: 10.1016/j.acra.2012.03.018
He M, Kaushik SS, Robertson SH, Freeman MS, Virgincar RS, McAdams HP et al (2014) Extending semiautomatic ventilation defect analysis for hyperpolarized 129Xe ventilation MRI. Acad Radiol 21(12):1530–1541
pubmed: 25262951
pmcid: 4254215
doi: 10.1016/j.acra.2014.07.017
Ebner L, He M, Virgincar RS, Heacock T, Kaushik SS, Freemann MS et al (2017) Hyperpolarized 129xenon magnetic resonance imaging to quantify regional ventilation differences in mild to moderate asthma: a prospective comparison between Semiautomated ventilation defect percentage calculation and pulmonary function tests. Invest Radiol 52(2):120–127
pubmed: 27662575
pmcid: 5488725
doi: 10.1097/RLI.0000000000000322
Svenningsen S, Kirby M, Starr D, Leary D, Wheatley A, Maksym GN et al (2013) Hyperpolarized
pubmed: 23589465
doi: 10.1002/jmri.24111
Walkup LL, Woods JC (2014) Translational applications of hyperpolarized
pubmed: 24953709
doi: 10.1002/nbm.3151
Willmering MM, Niedbalski PJ, Wang H, Walkup LL, Robison RK, Pipe JG et al (2020) Improved pulmonary
pubmed: 31788858
doi: 10.1002/mrm.28114
Collier GJ, Hughes PJC, Horn FC, Chan H, Tahir B, Norquay G et al (2019) Single breath-held acquisition of coregistered 3D
pubmed: 30821003
doi: 10.1002/mrm.27713
Driehuys B, Martinez-Jimenez S, Cleveland ZI, Metz GM, Beaver DM, Nouls JC et al (2012) Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized
pubmed: 22056683
pmcid: 3244666
doi: 10.1148/radiol.11102172
Hall CS, Quirk JD, Goss CW, Lew D, Kozlowski J, Thomen RP et al (2020) Single-session bronchial thermoplasty guided by
pubmed: 32510976
pmcid: 7427382
doi: 10.1164/rccm.201905-1021OC
Lin NY, Roach DJ, Willmering MM, Walkup LL, Hossain MM, Desirazu P et al (2021) 129Xe MRI as a measure of clinical disease severity for pediatric asthma. J Allergy Clin Immunol 147(6):2146–2153.e1
pubmed: 33227317
doi: 10.1016/j.jaci.2020.11.010
Thomen RP, Walkup LL, Roach DJ, Higano N, Schapiro A, Brody A et al (2020) Regional structure-function in cystic fibrosis lung disease using hyperpolarized
pubmed: 32243189
pmcid: 7365365
doi: 10.1164/rccm.202001-0031LE
Duan C, Deng H, Xiao S, Xie J, Li H, Zhao X et al (2022) Accelerate gas diffusion-weighted MRI for lung morphometry with deep learning. Eur Radiol 32(1):702–713
pubmed: 34255160
doi: 10.1007/s00330-021-08126-y
Zanette B, Santyr G (2019) Accelerated interleaved spiral-IDEAL imaging of hyperpolarized
pubmed: 30989730
Stewart NJ, Horn FC, Norquay G, Collier GJ, Yates DP, Lawson R et al (2017) Reproducibility of quantitative indices of lung function and microstructure from
pubmed: 27366901
doi: 10.1002/mrm.26310
Wang Z, Rankine L, Bier EA, Mummy D, Lu J, Church A et al (2021) Using hyperpolarized
pubmed: 33734831
pmcid: 8354826
doi: 10.1152/japplphysiol.00702.2020
Wang JM, Robertson SH, Wang Z, He M, Virgincar RS, Schrank GM et al (2018) Using hyperpolarized
pubmed: 28860333
doi: 10.1136/thoraxjnl-2017-210070
Qing K, Ruppert K, Jiang Y, Mata JF, Miller GW, Shim YM et al (2014) Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon-129 MRI: Lung MRI of Xe129 Uptake by Blood and Tissue. J Magn Reson Imaging 39(2):346–359
pubmed: 23681559
doi: 10.1002/jmri.24181
Xiao Q, Stewart NJ, Willmering MM, Gunatilaka CC, Thomen RP, Schuh A et al (2021) Human upper-airway respiratory airflow: In vivo comparison of computational fluid dynamics simulations and hyperpolarized 129Xe phase contrast MRI velocimetry. PLoS ONE 16(8):e256460
pubmed: 34411195
pmcid: 8376109
doi: 10.1371/journal.pone.0256460
Torkian P, Rajebi H, Zamani T, Ramezani N, Kiani P, Akhlaghpoor S (2021) Magnetic resonance imaging features of coronavirus disease 2019 (COVID-19) pneumonia: the first preliminary case series. Clin Imaging 69:261–265
pubmed: 33002753
doi: 10.1016/j.clinimag.2020.09.002
Yang S, Zhang Y, Shen J, Dai Y, Ling Y, Lu H et al (2020) Clinical potential of UTE-MRI for assessing COVID-19: patient- and lesion-based comparative analysis. J Magn Reson Imaging 52(2):397–406
pubmed: 32491257
doi: 10.1002/jmri.27208
Huang Y, Tan C, Wu J, Chen M, Wang Z, Luo L et al (2020) Impact of coronavirus disease 2019 on pulmonary function in early convalescence phase. Respir Res 21(1):163
pubmed: 32600344
pmcid: 7323373
doi: 10.1186/s12931-020-01429-6
Grist JT, Chen M, Collier GJ, Raman B, Abueid G, McIntyre A et al (2021) Hyperpolarized
pubmed: 34032513
doi: 10.1148/radiol.2021210033