Measurement of retina/choroid complex perfusion with magnetic resonance imaging in eyes with acute primary angle-closure.


Journal

Arquivos brasileiros de oftalmologia
ISSN: 1678-2925
Titre abrégé: Arq Bras Oftalmol
Pays: Brazil
ID NLM: 0400645

Informations de publication

Date de publication:
2021
Historique:
received: 01 07 2020
accepted: 28 09 2020
entrez: 13 4 2022
pubmed: 14 4 2022
medline: 16 4 2022
Statut: epublish

Résumé

To measure retina/choroid complex perfusion with magnetic resonance imaging in eyes with acute primary angle-closure (APAC). Three sequences of magnetic resonance imaging, two anatomical and one perfusional using gadolinium, were acquired in patients who were diagnosed with acute primary angle-closure. Regions of interest were drawn on the perfusional sequence and overlaid to the anatomical sequence. The relative blood volume measured during the first 2 s was considered as the baseline value and the change during the subsequent 28 s was analyzed. Five eyes of 5 patients with acute primary angle-closure were included (3 with unilateral and 2 with bilateral acute primary angle-closure). Three contralateral eyes and 2 eyes of 2 healthy patients, paired for age and sex, were included in the control group. Acute primary angle-closure patients included 4 (80%) women, with an average age of 65.8 ± 12.37 y, mean intraocular pressure of 56.2 ± 14.67 mmHg, mean arterial pressure of 113.4 ± 8.17 mmHg, and average ocular perfusion pressure of 57.2 ± 13.46 mmHg. In the control group, the mean intraocular pressure was 15.6 ± 2.61 mmHg (p=0.0625), the mean arterial pressure was 107.4 ± 6.57 mmHg (p=1.00), and the average ocular perfusion pressure was 91.8 ± 6.72 mmHg (p=0.0625). The relative blood volume of the retina/choroid complex was -0.127 ± 0.048 in acute primary angle-closure patients and -0.213 ± 0.116 in the controls (p=0.3125). The magnetic resonance imaging sequence with gadolinium did not show a change in the retina/choroid complex perfusion in the eyes of patients with acute primary angle-closure.

Identifiants

pubmed: 35416899
pii: S0004-27492020005007218
doi: 10.5935/0004-2749.20220034
pii:
doi:

Substances chimiques

Gadolinium AU0V1LM3JT

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

166-173

Auteurs

Gabriel Ayub (G)

Department de Ophthalmology, University of Campinas, Campinas, Brazil.

Brunno M Campos (BM)

Neuroimaging Laboratory, University of Campinas, Campinas, Brazil.

Thiago J R Rezende (TJR)

Medical Physics Laboratory, University of Campinas, Campinas, Brazil.

Fernando Cendes (F)

Neuroimaging Laboratory, University of Campinas, Campinas, Brazil.

José Paulo Cabral de Vasconcelos (JPC)

Department de Ophthalmology, University of Campinas, Campinas, Brazil.

Vital Paulino Costa (VP)

Department de Ophthalmology, University of Campinas, Campinas, Brazil.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH