Stereotactic Localization: From Single-Slice to Multi-Slice Registration Including a Novel Solution for Parallel Bipanels.

frame-based stereotactic surgery functional neurosurgery localization stereotactic and functional neurosurgery stereotactic frame

Journal

Cureus
ISSN: 2168-8184
Titre abrégé: Cureus
Pays: United States
ID NLM: 101596737

Informations de publication

Date de publication:
Mar 2022
Historique:
accepted: 17 03 2022
entrez: 22 4 2022
pubmed: 23 4 2022
medline: 23 4 2022
Statut: epublish

Résumé

Frame-based stereotactic localization generally assumes that all required fiducials are present in a single-slice image which can then be used to form targeting coordinates. Previously, we have published the use of novel localizers and mathematics that can improve stereotactic localization. As stereotactic procedures include numerous imaging slices, we sought to investigate, develop, and test techniques that utilize multiple slices for stereotactic localization and provide a solution for a parallel bipanel N-localizer.  Several multi-slice equations were tested. Specifically, multi-slice stereotactic matrices (ms-SM) and multi-slice normal to parallel planes (ms-nPP) were of particular interest. Bipanel (2N) and tripanel (3N) localizer images were explored to test approaches for stereotactic localization. In addition, combination approaches using single-slice stereotactic matrices (ss-SM) and multi-slice methods were tested. Modification of ss-SM to form ms-SM was feasible. Likewise, a method to determine ms-nPP was developed. For the special case of the parallel bipanel N-localizer, single-slice and multi-slice methods fail, but a novel non-linear solution is a robust solution for ms-nPP. Several methods for single-slice and multi-slice stereotactic localization are described and can be adapted for nearly any stereotactic system. It is feasible to determine ms-SM and ms-nPP. In particular, these methods provide an overdetermined means to calculate the vertical z, which is determined for a tripanel system using single-slice methods. In addition, the multi-slice methods can be used for extrapolation outside of the localizer space. Importantly, a novel non-linear solution can be used for parallel bipanel N-localizer systems, where other methods fail. Finally, multi-slice stereotactic localization assumes strict patient and imaging system stability, which should be carefully assessed for each case.

Identifiants

pubmed: 35449621
doi: 10.7759/cureus.23279
pmc: PMC9012578
doi:

Types de publication

Journal Article

Langues

eng

Pagination

e23279

Informations de copyright

Copyright © 2022, Sedrak et al.

Déclaration de conflit d'intérêts

The authors have declared that no competing interests exist.

Références

Cureus. 2015 Oct 02;7(10):e341
pubmed: 26594605
J Neurosci Methods. 2016 May 1;264:47-56
pubmed: 26945974
Cureus. 2020 Jul 11;12(7):e9137
pubmed: 32685325
Neurosurg Rev. 1999 Dec;22(4):188-203; discussion 204
pubmed: 10682927
Cureus. 2020 Apr 30;12(4):e7904
pubmed: 32494519
Oper Neurosurg (Hagerstown). 2020 Sep 1;19(3):302-312
pubmed: 31858143
Neurosurg Focus. 2009 Sep;27(3):E12
pubmed: 19722814
Cureus. 2015 Sep 14;7(9):e323
pubmed: 26487999
Invest Radiol. 1979 Jul-Aug;14(4):300-4
pubmed: 385549
J Neurosurg. 1979 Jun;50(6):715-20
pubmed: 374688
Cureus. 2020 Jun 12;12(6):e8578
pubmed: 32670714
Cureus. 2021 Feb 17;13(2):e13393
pubmed: 33758694
Cureus. 2021 Jul 21;13(7):e16535
pubmed: 34327109
Stereotact Funct Neurosurg. 2016;94(6):351-362
pubmed: 27784015
Cureus. 2021 Jun 13;13(6):e15620
pubmed: 34277238
Science. 1947 Oct 10;106(2754):349-50
pubmed: 17777432

Auteurs

Mark Sedrak (M)

Neurosurgery, Kaiser Permanente, Redwood City, USA.

Andres E Bruna (AE)

Medical Physics, Fisica Médica SRL, Córdoba, ARG.

Armando L Alaminos-Bouza (AL)

Medical Physics, MEVIS Informática Médica Ltda., São Paulo, BRA.

Classifications MeSH