Effectiveness of non-uniform thickness on a locking compression plate used as a biodegradable bone implant plate.

Biodegradable femur bone locking compression plate mg-alloy non-uniform thickness

Journal

Journal of biomaterials applications
ISSN: 1530-8022
Titre abrégé: J Biomater Appl
Pays: England
ID NLM: 8813912

Informations de publication

Date de publication:
09 2022
Historique:
pubmed: 28 4 2022
medline: 19 8 2022
entrez: 27 4 2022
Statut: ppublish

Résumé

Conventional locking compression plate (LCP) made of non-biodegradable materials are well-known bone implants for internal fracture fixation because of their proven experimental success. LCP, however, is mechanically underpowered when made up of biodegradable materials (even with Mg-alloy). The biodegradable implant plate should not only exhibit adequate mechanical performance during implantation but also perform well after fracture, at least until complete healing of the fractured bone. With the aim of achieving enhanced mechanical performance, the design of the LCP has been modified to the design of Biodegradable Locking Compression Plate (BLCP) by adding a suitable thickness in the middle (only 4.6% of the total volume of the LCP), which may help retain some additional strength during implantation and after degradation. Both BLCP and LCP have been comparatively analyzed via FEM with the aid of axial compression and four-point bending tests. BLCP has a better mechanical capability of withstanding loads in its degraded form than in its non-degradable form. Furthermore, BLCP is up to 15.83% mechanically better in the non-degraded form as compared to LCP, which again becomes up to 100% more mechanically adequate in the degraded forms of BLCP than in LCP. BLCP is found safe for degradation up to 2 mm or 6 months with an estimated degradation rate of 4 mm/year, which may allow it to support fractured bone for at least the standard healing time. BLCP can be considered as a superior biodegradable bone implant plate after experimental assurance with the physiological environment and may replace LCP.

Identifiants

pubmed: 35473434
doi: 10.1177/08853282221094458
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

429-446

Auteurs

Gourav Singh (G)

Department of Mechanical Engineering, 29678Maulana Azad National Institute of Technology, Bhopal, India.

Ajay Pandey (A)

Department of Mechanical Engineering, 29678Maulana Azad National Institute of Technology, Bhopal, India.

Girish Chandra (G)

Department of Mechanical Engineering, 29678Maulana Azad National Institute of Technology, Bhopal, India.

Articles similaires

Humans Arthroplasty, Replacement, Knee Osteoarthritis, Knee Awards and Prizes Biomechanical Phenomena
Humans Reoperation Middle Aged Female Male

Contemporary insights into spinopelvic mechanics.

Andreas Fontalis, Daniel Buchalter, Fabio Mancino et al.
1.00
Humans Biomechanical Phenomena Arthroplasty, Replacement, Hip Spine Hip Prosthesis

Classifications MeSH