Novel fabrication technique for high-resolution spherical crystal analyzers using a microporous aluminium base.
inelastic X-ray scattering
microporous aluminium
spherical crystal analyzers
Journal
Journal of synchrotron radiation
ISSN: 1600-5775
Titre abrégé: J Synchrotron Radiat
Pays: United States
ID NLM: 9888878
Informations de publication
Date de publication:
01 May 2022
01 May 2022
Historique:
received:
23
09
2021
accepted:
17
02
2022
entrez:
5
5
2022
pubmed:
6
5
2022
medline:
6
5
2022
Statut:
ppublish
Résumé
Modern inelastic X-ray spectrometers employ curved, bent and diced analyzers to capture sufficiently large solid angles of radially emitted scattered radiation emanating from the sample. Fabricating these intricate analyzers, especially when a high energy resolution of a few millielectronvolts is required, is very time-consuming, expensive and often a hit-or-miss affair. A novel fabrication technique is introduced, utilizing a concave-spherical, microporous aluminium base to hold an assembly of a thin glass substrate with a diced crystal wafer bonded to it. Under uniform vacuum forces, the glass substrate is drawn into the aluminium base, achieving the desired bending radius, while dicing of the diffracting crystal layer prevents bending strain from being imposed on the individual crystal pixels. This technique eliminates the need for permanently bonding the crystal assembly to the concave lens, offering the opportunity for correcting figure errors, avoiding long-term degradation of the permanent bond, and making both lens and crystal reusable. Process and material costs are thus substantially decreased. Two analyzers, Si(844) and Ge(337) with intrinsic resolutions of 14.6 meV and 36.5 meV, respectively, were produced in this fashion and characterized in resonant inelastic X-ray scattering (RIXS) measurements. The achieved overall energy resolutions for both analyzers were 29.4 meV for Si(844) and 56.6 meV for Ge(337). Although the RIXS technique is veru sensitive to analyzer imperfections, the analyzers were found to be equal, if not superior, in quality to their traditional, permanently bonded counterparts.
Identifiants
pubmed: 35511007
pii: S1600577522001886
doi: 10.1107/S1600577522001886
pmc: PMC9070708
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
749-754Subventions
Organisme : US Department of Energy, Office of Science, Office of Basic Energy Sciences
ID : DE-AC02-06CH11357
Informations de copyright
open access.