Homogeneity assessment of the SuperCam calibration targets onboard rover perseverance.
Elemental homogeneity
Mars2020
Mineral homogeneity
Perseverance rover
SuperCam calibration target
Uncertainties
Journal
Analytica chimica acta
ISSN: 1873-4324
Titre abrégé: Anal Chim Acta
Pays: Netherlands
ID NLM: 0370534
Informations de publication
Date de publication:
29 May 2022
29 May 2022
Historique:
received:
18
01
2022
revised:
17
03
2022
accepted:
13
04
2022
entrez:
15
5
2022
pubmed:
16
5
2022
medline:
20
5
2022
Statut:
ppublish
Résumé
The SuperCam instrument, onboard the Perseverance rover (Mars 2020 mission) is designed to perform remote analysis on the Martian surface employing several spectroscopic techniques such as Laser Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman (TRR), Time-Resolved Fluorescence (TRF) and Visible and Infrared (VISIR) reflectance. In addition, SuperCam also acquires high-resolution images using a color remote micro-imager (RMI) as well as sounds with its microphone. SuperCam has three main subsystems, the Mast Unit (MU) where the laser for chemical analysis and collection optics are housed, the Body Unit (BU) where the different spectrometers are located inside the rover, and the SuperCam Calibration Target (SCCT) located on the rover's deck to facilitate calibration tests at similar ambient conditions as the analyzed samples. To perform adequate calibrations on Mars, the 22 mineral samples included in the complex SCCT assembly must have a very homogeneous distribution of major and minor elements. The analysis and verification of such homogeneity for the 5-6 replicates of the samples included in the SCCT has been the aim of this work. To verify the physic-chemical homogeneity of the calibration targets, micro Energy Dispersive X-ray Fluorescence (EDXRF) imaging was first used on the whole surface of the targets, then the relative abundances of the detected elements were computed on 20 randomly distributed areas of 100 × 100 μm. For those targets showing a positive Raman response, micro-Raman spectroscopy imaging was performed on the whole surface of the targets at a resolution of 100 × 100 μm. The %RSD values (percent of relative standard deviation of mean values) for the major elements measured with EDXRF were compared with similar values obtained by two independent LIBS set-ups at spot sizes of 300 μm in diameter. The statistical analysis showed which elements were homogeneously distributed in the 22 mineral targets of the SCCT, providing their uncertainty values for further calibration. Moreover, nine of the 22 targets showed a good Raman response and their mineral distributions were also studied. Those targets can be also used for calibration purposes of the Raman part of SuperCam using the wavenumbers of their main Raman bands proposed in this work.
Identifiants
pubmed: 35569848
pii: S0003-2670(22)00408-1
doi: 10.1016/j.aca.2022.339837
pii:
doi:
Substances chimiques
Minerals
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
339837Informations de copyright
Copyright © 2022 The Authors. Published by Elsevier B.V. All rights reserved.