New 3-Dimensional Volumetric Ultrasound Method for Accurate Quantification of Atherosclerotic Plaque Volume.
accuracy
atherosclerotic plaque
gold-standard
plaque volume
three-dimensional
vascular ultrasound
Journal
JACC. Cardiovascular imaging
ISSN: 1876-7591
Titre abrégé: JACC Cardiovasc Imaging
Pays: United States
ID NLM: 101467978
Informations de publication
Date de publication:
06 2022
06 2022
Historique:
received:
30
06
2021
revised:
01
01
2022
accepted:
06
01
2022
entrez:
9
6
2022
pubmed:
10
6
2022
medline:
14
6
2022
Statut:
ppublish
Résumé
Carotid and femoral plaque burden is a recognized biomarker of cardiovascular disease risk. A new electronic-sweep 3-dimensional (3D)-matrix transducer method can improve the functionality and image quality of vascular ultrasound atherosclerosis imaging. This study aimed to validate this method for plaque volume measurement in early and intermediate-advanced plaques in the carotid and femoral territories. Plaque volumes were measured ex vivo in pig carotid and femoral artery specimens by 3-dimensional vascular ultrasound (3DVUS) using a 3D-matrix (electronic-sweep) transducer and its associated 3D plaque quantification software, and were compared with gold-standard histology. To test the clinical feasibility and accuracy of the 3D-matrix transducer, an experiment was conducted in intermediate-high risk individuals with carotid and femoral atherosclerosis. The results were compared with those obtained using the previously validated mechanical-sweep 3D transducer and established 2-dimensional (2D)-based plaque quantification software. In the ex vivo study, the authors assessed 19 atherosclerotic plaques (plaque volume, 0.76 µL-56.30 μL), finding strong agreement between measurements with the 3D-matrix transducer and the histological gold-standard (intraclass correlation coefficient [ICC]: 0.992; [95% CI: 0.978-0.997]). In the clinical analysis of 20 patients (mean age 74.6 ± 4.45 years; 40% men), the authors found 64 (36 carotid and 28 femoral) of 80 scanned territories with atherosclerosis (measured atherosclerotic volume, 10 μL-859 μL). There was strong agreement between measurements made from electronic-sweep and mechanical-sweep 3DVUS transducers (ICC: 0.997 [95% CI: 0.995-0.998]). Agreement was also high between plaque volumes estimated by the 2D and 3D plaque quantification software applications (ICC: 0.999 [95% CI: 0.998-0.999]). Analysis time was significantly shorter with the 3D plaque quantification software than with the 2D multislice approach with a mean time reduction of 46%. 3DVUS using new matrix transducer technology, together with improved 3D plaque quantification software, simplifies the accurate volume measurement of early (small) and intermediate-advanced plaques located in carotid and femoral arteries.
Sections du résumé
BACKGROUND
Carotid and femoral plaque burden is a recognized biomarker of cardiovascular disease risk. A new electronic-sweep 3-dimensional (3D)-matrix transducer method can improve the functionality and image quality of vascular ultrasound atherosclerosis imaging.
OBJECTIVES
This study aimed to validate this method for plaque volume measurement in early and intermediate-advanced plaques in the carotid and femoral territories.
METHODS
Plaque volumes were measured ex vivo in pig carotid and femoral artery specimens by 3-dimensional vascular ultrasound (3DVUS) using a 3D-matrix (electronic-sweep) transducer and its associated 3D plaque quantification software, and were compared with gold-standard histology. To test the clinical feasibility and accuracy of the 3D-matrix transducer, an experiment was conducted in intermediate-high risk individuals with carotid and femoral atherosclerosis. The results were compared with those obtained using the previously validated mechanical-sweep 3D transducer and established 2-dimensional (2D)-based plaque quantification software.
RESULTS
In the ex vivo study, the authors assessed 19 atherosclerotic plaques (plaque volume, 0.76 µL-56.30 μL), finding strong agreement between measurements with the 3D-matrix transducer and the histological gold-standard (intraclass correlation coefficient [ICC]: 0.992; [95% CI: 0.978-0.997]). In the clinical analysis of 20 patients (mean age 74.6 ± 4.45 years; 40% men), the authors found 64 (36 carotid and 28 femoral) of 80 scanned territories with atherosclerosis (measured atherosclerotic volume, 10 μL-859 μL). There was strong agreement between measurements made from electronic-sweep and mechanical-sweep 3DVUS transducers (ICC: 0.997 [95% CI: 0.995-0.998]). Agreement was also high between plaque volumes estimated by the 2D and 3D plaque quantification software applications (ICC: 0.999 [95% CI: 0.998-0.999]). Analysis time was significantly shorter with the 3D plaque quantification software than with the 2D multislice approach with a mean time reduction of 46%.
CONCLUSIONS
3DVUS using new matrix transducer technology, together with improved 3D plaque quantification software, simplifies the accurate volume measurement of early (small) and intermediate-advanced plaques located in carotid and femoral arteries.
Identifiants
pubmed: 35680220
pii: S1936-878X(22)00048-1
doi: 10.1016/j.jcmg.2022.01.005
pii:
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1124-1135Commentaires et corrections
Type : CommentIn
Informations de copyright
Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Funding Support and Author Disclosures This study was partially funded by grants from the Ministerio de Economia, Industria y Competividad (MEIC) with cofunding from the European Regional Development Fund (ERDF) (SAF2016-75580-R to Dr Bentzon) and (BES-2016-076633 to Dr Nogales). Research funding was also received from the Instituto de Salud Carlos III Spain (PIE16/00021 to Drs Bueno and Fuster). The CNIC is supported by the Ministerio de Ciencia, Innovacion y Universidades (MICINN) and the Pro CNIC Foundation and is a Severo Ochoa Center of Excellence (CEX2020-001041-S). This study forms part of a Master Research Agreement between the CNIC and Philips Healthcare. Drs Sánchez-González, Entrekin, and Collet-Billon are employees of Philips Healthcare. All other authors have reported that they have no relationships to disclose related to the contents of this paper.