A Cadaveric Comparison of Approaches for Exposure of the Volar Distal Radius: Is There a Utilitarian Approach?

anatomy distal radius exposures extended FCR volar ulnar corner

Journal

Hand (New York, N.Y.)
ISSN: 1558-9455
Titre abrégé: Hand (N Y)
Pays: United States
ID NLM: 101264149

Informations de publication

Date de publication:
13 Jun 2022
Historique:
pubmed: 14 6 2022
medline: 14 6 2022
entrez: 13 6 2022
Statut: aheadofprint

Résumé

It remains unclear whether exposure for planned fixation of distal radius fractrues is superior with any given approach, and whether a single utilitarian approach exists that permits reliable complete exposure of the volar distal radius. A cadaveric study was performed using 10 matched specimens. Group 1 consisted of 3 radially based approaches (standard flexor carpi radialis [FCR], standard FCR with radial retraction of FCR and flexor pollicis longus [FPL] tendons, extended FCR). Group 2 consisted of 2 ulnarly based approaches (volar ulnar, extended carpal tunnel). The primary outcome was total width of exposed distal radius at the watershed line. Mann-Whitney The standard FCR approach exposed 29 mm (90%), leaving on average 3 mm (10%) of the ulnar corner unexposed. Retracting the FCR and FPL tendons radially allows for an extra 1 mm of volar ulnar corner exposure. Finally, converting to an extended FCR approach provided 100% exposure in all specimens. The volar ulnar exposure however provided exposure to only 9 mm (37%), leaving 20 mm (62.5%) left unexposed radially. The extended carpal tunnel provided exposure to 21 mm (65%), leaving 11 mm (35%) radially unexposed. Differences between each group were statistically significant ( The extended FCR approach exposed 100% of the volar distal radius in our study and may serve as a utilitarian volar surgical approach for exposure and fixation of distal radius fractures. Additional knowledge of the limitations of alternative approaches can be helpful in surgical planning.

Sections du résumé

BACKGROUND UNASSIGNED
It remains unclear whether exposure for planned fixation of distal radius fractrues is superior with any given approach, and whether a single utilitarian approach exists that permits reliable complete exposure of the volar distal radius.
METHODS UNASSIGNED
A cadaveric study was performed using 10 matched specimens. Group 1 consisted of 3 radially based approaches (standard flexor carpi radialis [FCR], standard FCR with radial retraction of FCR and flexor pollicis longus [FPL] tendons, extended FCR). Group 2 consisted of 2 ulnarly based approaches (volar ulnar, extended carpal tunnel). The primary outcome was total width of exposed distal radius at the watershed line. Mann-Whitney
RESULTS UNASSIGNED
The standard FCR approach exposed 29 mm (90%), leaving on average 3 mm (10%) of the ulnar corner unexposed. Retracting the FCR and FPL tendons radially allows for an extra 1 mm of volar ulnar corner exposure. Finally, converting to an extended FCR approach provided 100% exposure in all specimens. The volar ulnar exposure however provided exposure to only 9 mm (37%), leaving 20 mm (62.5%) left unexposed radially. The extended carpal tunnel provided exposure to 21 mm (65%), leaving 11 mm (35%) radially unexposed. Differences between each group were statistically significant (
CONCLUSIONS UNASSIGNED
The extended FCR approach exposed 100% of the volar distal radius in our study and may serve as a utilitarian volar surgical approach for exposure and fixation of distal radius fractures. Additional knowledge of the limitations of alternative approaches can be helpful in surgical planning.

Identifiants

pubmed: 35695337
doi: 10.1177/15589447221094320
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

15589447221094320

Auteurs

William J Warrender (WJ)

South Bend Orthopaedics, IN, USA.

Daniel J Wagner (DJ)

The Ohio State University, Columbus, USA.

Reed W Hoyer (RW)

Indiana Hand to Shoulder Center, Indianapolis, USA.

Gregory A Merrell (GA)

Indiana Hand to Shoulder Center, Indianapolis, USA.

William B Kleinman (WB)

Indiana Hand to Shoulder Center, Indianapolis, USA.

Brandon S Smetana (BS)

Indiana Hand to Shoulder Center, Indianapolis, USA.

Classifications MeSH