Wearable hollow microneedle sensing patches for the transdermal electrochemical monitoring of glucose.
Amperometric biosensor
Continuous glucose monitoring
Diabetes
Hollow microneedle array
Transdermal sensing
Wearable electrochemical sensor
Journal
Talanta
ISSN: 1873-3573
Titre abrégé: Talanta
Pays: Netherlands
ID NLM: 2984816R
Informations de publication
Date de publication:
01 Nov 2022
01 Nov 2022
Historique:
received:
08
04
2022
revised:
07
06
2022
accepted:
13
06
2022
pubmed:
22
6
2022
medline:
8
9
2022
entrez:
21
6
2022
Statut:
ppublish
Résumé
According to the World Health Organization, about 422 million people worldwide have diabetes, with 1.5 million deaths directly attributed each year. Therefore, there is still a need to effectively monitor glucose in diabetic patients for proper management. Recently, wearable patches based on microneedle (MN) sensors provide minimally invasive analysis of glucose through the interstitial fluid (ISF) while exhibiting excellent correlation with blood glucose. Despite many advances in wearable electrochemical sensors, long-term stability and continuous monitoring remain unsolved challenges. Herein, we present a highly stable electrochemical biosensor based on a redox mediator bilayer consisting of Prussian blue and iron-nickel hexacyanoferrate to increase the long-term stability of the readout coupled with a hollow MN array as a sampling unit for ISF uptake. First, the enzymatic biosensor is developed by using affordable screen-printed electrodes (SPE) and optimized for long-term stability fitting the physiological range of glucose in ISF (i.e., 2.5-22.5 mM). In parallel, the MN array is assessed for minimally invasive piercing of the skin. Subsequently, the biosensor is integrated with the MN array leaving a microfluidic spacer that works as the electrochemical cell. Interestingly, a microfluidic channel connects the cell with an external syringe to actively and rapidly withdraw ISF toward the cell. Finally, the robust MN sensing patch is characterized during in vitro and ex vivo tests. Overall, affordable wearable MN-based patches for the continuous monitoring of glucose in ISF are providing an advent in wearable devices for rapid and life-threatening decision-making processes.
Identifiants
pubmed: 35728453
pii: S0039-9140(22)00491-X
doi: 10.1016/j.talanta.2022.123695
pii:
doi:
Substances chimiques
Glucose
IY9XDZ35W2
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
123695Informations de copyright
Copyright © 2022 Elsevier B.V. All rights reserved.