Proposal of a novel protocol using estimated cardiac index fractional dose to improve aortic contrast enhancement for early-phase dynamic CT.


Journal

Medicine
ISSN: 1536-5964
Titre abrégé: Medicine (Baltimore)
Pays: United States
ID NLM: 2985248R

Informations de publication

Date de publication:
24 Jun 2022
Historique:
received: 11 08 2021
accepted: 18 04 2022
entrez: 27 6 2022
pubmed: 28 6 2022
medline: 29 6 2022
Statut: epublish

Résumé

Maximum aortic computed tomography value (CTV) is difficult to control because of variations in cardiac function and patient physique. Therefore, to improve early-phase aortic enhancement on dynamic computed tomography (CT), we developed an estimated cardiac index fractional dose (eciFD). The eciFD protocol is a novel and original protocol for administering fractional dose (FD), representing the amount of iodine per unit body weight per injection duration, based on cardiac index (cardiac output divided by body surface area) as estimated by age in early-phase dynamic CT. At the time of administration, by selecting FD based on the patient's age and selecting a parameter that can achieve this FD, an aortic CTV ≥300 HU (ACTV≥300) can be obtained. This study aimed to investigate aortic enhancement on CT angiography using the eciFD protocol.This retrospective study investigated 291 consecutive patients who underwent dynamic CT from neck to abdomen after recommendation of the eciFD protocol at our institution. We compared early-phase aortic CTV distributions by scan delay between an eciFD group (eciFD applied, n = 135) and a non-eciFD group (eciFD not applied, n = 80). The effect of eciFD on early-phase ACTV≥300 was evaluated using logistic regression analysis adjusted for several potentially meaningful clinical confounders related to aortic CTV, namely male sex, heart rate ≤80 beats/min, estimated glomerular filtration rate ≤40 mL/min, use of eciFD, bolus tracking (BT), history of myocardial infarction, and order from the emergency center.The eciFD protocol was a significant factor for early-phase ACTV≥300 after adjusting for several confounders (odds ratio 3.03; 95% confidence intervals 1.59-5.77; P = .001). No interaction was seen between BT and eciFD protocol (p for interaction = 0.76). In terms of CTV distribution, with both a fixed scan delay time and BT, the eciFD group showed a high aortic CTV. The combination of eciFD protocol with BT provided a particularly high percentage of patients with ACTV≥300 (86.4%).The eciFD protocol was useful for improving aortic contrast enhancement. These findings need to be validated in a randomized controlled study.

Identifiants

pubmed: 35758375
doi: 10.1097/MD.0000000000029410
pii: 00005792-202206240-00032
pmc: PMC9276326
doi:

Substances chimiques

Contrast Media 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e29410

Informations de copyright

Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc.

Déclaration de conflit d'intérêts

The authors have no conflicts of interest to disclose.

Références

Higashigaito K, Schmid T. CT angiography of the aorta: prospective evaluation of individualized low-volume contrast media protocols. Radiology 2016;280:960–8.
Solbak MS, Henning MK. Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT. Eur Radiol Exp 2020;4:57.
Matsumoto Y, Higaki T, Masuda T, et al. Minimizing individual variations in arterial enhancement on coronary CT angiographs using “contrast enhancement optimizer”: a prospective randomized single-center study. Eur Radiol 2019;29:2998–3005.
X-sen CT satsueiniokeruhyōjunka (Standardization in X-ray CT Imaging) [translated from Japanese]. Guideline for All about CT Exam (GALACTIC). 2nd ed. Tokyo: Japanese Society of Radiological Technology. 135.
Hacchou A, Terasawa K. CT zōeigijutsu (CT Contrast Enhanced Technology) [translated from Japanese]. Tokyo: Medical Eye; 2013. 38.
X-sen CT satsueiniokeruhyōjunka (Standardization in X-ray CT Imaging) [translated from Japanese]. Guideline for All about CT Exam (GALACTIC). 2nd ed. Tokyo: Japanese Society of Radiological Technology. 136.
Declaration of Helsinki, The World Medical Association; 2013.
Awai K, Jinzaki M. New Textbook of Body CT Diagnosis. Tokyo, Japan: Medical Science International; 2018. 112.
Yoshioka K, Niinuma H, Ohira A, et al. MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 2003;23:1215–25.
Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010;256:50–5.
Guyton AC, Hall JE. Text Book of Medical Physiology. 11th ed.2006;Philadelphia, Pennsylvania: Elsevier Sanders, 232–233.
Akiyama N, Nakamura Y. Optimization of contrast injection protocol for coronary CTA: adjustment of injection iodine volume on test bolus prarameters and patient’ sex and BSA. Nihon Hoshasen Gijutsu Gakkai Zasshi 2009;65:1073–80.
Awai K, Hiraishi K. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored patient weight. Radiology 2004;230:142–50.
Paulson EK, Fisher AJ, Delong DM, et al. Helical liver CT with computer-assisted bolus-tracking technology: is it possible to predict which patients will not achieve a threshold of enhancement? Radiology 1998;209:787–92.
Kirchner J, Kichuth R, Laufer U, et al. Optimized enhancement in helical CT: experience with a real-time bolus tracking system in 628 patients. Clin Radiol 2000;55:368–73.
Sandstede JJ, Tshammler A, Beer M, et al. Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol 2001;11:1396–400.
Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010;256:55.
Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT. II. Effect of reduced cardiac output in a porcine model. Radiology 1998;207:657–62.
Masuda T, Nakakura T, et al. Effect of patient characteristics on vessel enhancement at lower extremity CT angiography. Korean J Radiol 2018;19:265–71.
Taguchi N, Oda S, et al. Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50% in patients at risk for contrast-induced nephropathy. Eur Radiol 2017;27:812–20.
Nakaura T, Kidoh M, et al. Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm. J Cardiovasc Imaging 2013;29:913–23.
Nakaura T, Awai K, Maruyama N, et al. Abdominal dynamic CT in patients with renal dysfunction: contrast agent dose reduction with low tube voltage and high tube current–time product settings at 256–detector row CT. Radiology 2011;261:467–76.
Clark ZE, Bolus DN, Little MD, Morgan DE. Abdominal rapid-kVp-switching dual-energy MDCT with reduced IV contrast compared to conventional MDCT with standard weight based IV contrast: an intra-patient comparison. Abdom Imaging 2015;40:852–8.
Shuman WP, Chan K, Busey JM, et al. Dual-energy CT aortography with 50% reduced iodine dose versus single-energy CT aortography with standard iodine dose. Acad Radiol 2016;23:611–8.
Nakakura T, Awai K, Maruyama N, et al. Abdominal dynamic CT in patients with renal dysfunction: contrast agent dose reduction with low tube voltage and high tube current time product settings at 256-detector row CT. Radiology 2011;261:467–76.
Goshima S, Kanematsu M, Noda Y, et al. Minimally required iodine dose for the detection of hypervascular hepatocellular carcinoma on 80-kVp CT. Am J Roentgenol 2016;206:518–25.
Kidoh M, Nakaura T, Awai K, et al. Novel connecting tube for saline chaser in contrast enhanced CT: the effect of spiral flow of saline on contrast enhancement. Eur Radiol 2013;23:3213–8.
Masuda T, Funama Y, Nakaura T, et al. Delivering the saline chaser via a spiral flow-generating tube improves arterial enhancement for computed tomography angiography of the lower extremities. J Comput Assist Tomogr 2015;39:962–8.
Tatsugami F, Matsuki M, Inada Y, et al. Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time–density curve for the aorta, portal vein and liver. Br J Radiol 2007;80:231–4.
Awai K, Jinzaki M. New Textbook of Body CT Diagnosis. 2018;Tokyo, Japan: Medical Science International, 50.

Auteurs

Tadashi Kuba (T)

Department of Clinical Research and Quality Management, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan.

Akihiro Tokushige (A)

Department of Clinical Pharmacology and Therapeutics, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan.

Sadayuki Murayama (S)

Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan.

Shinichiro Ueda (S)

Department of Clinical Pharmacology and Therapeutics, Graduate School of Medical Science, University of the Ryukyus, Okinawa, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH