Endoscopic Lung Volume Reduction with One-Way Valves in Patients with Severe Chronic Obstructive Pulmonary Disease with Hypercapnia.
Chronic obstructive pulmonary disease
Endoscopic lung volume reduction
Hypercapnia
Valves
Journal
Respiration; international review of thoracic diseases
ISSN: 1423-0356
Titre abrégé: Respiration
Pays: Switzerland
ID NLM: 0137356
Informations de publication
Date de publication:
2022
2022
Historique:
received:
23
09
2021
accepted:
19
04
2022
pubmed:
6
7
2022
medline:
9
9
2022
entrez:
5
7
2022
Statut:
ppublish
Résumé
Robust clinical evidence on the efficacy and safety of endoscopic lung volume reduction (ELVR) with one-way valves in patients with severe lung emphysema with chronic hypercapnic respiratory failure is lacking. The aim of this study was to compare patient characteristics, clinical outcome measures, and incidences of adverse events between patients with severe COPD undergoing ELVR with one-way valves and with either a partial pressure of carbon dioxide (pCO2) of ≤45 mm Hg or with pCO2 >45 mm Hg. This was a multicentre prospective study of patients with severe lung disease who were evaluated based on lung function, exercise capacity (6-min walk test [6-MWT]), and quality-of-life tests. Patients with pCO2 ≤45 mm Hg (n = 157) and pCO2 >45 mm Hg (n = 40) showed similar baseline characteristics. Patients with pCO2 ≤45 mm Hg demonstrated a significant increase in forced expiratory volume in 1 s (p < 0.001), a significant decrease in residual volume (RV) (p < 0.001), and significant improvements in the quality of life and 6-MWT at the 3-month follow-up. Patients with pCO2 >45 mm Hg had significant improvements in RV only (p < 0.05). There was a significant decrease in pCO2 between baseline and follow-up in hypercapnic patients, relative to the decrease in patients with pCO2 ≤45 mm Hg (p = 0.008). Patients who were more hypercapnic at baseline showed a greater reduction in pCO2 after valve placement (r = -0.38, p < 0.001). Pneumothorax was the most common adverse event in both groups. ELVR with one-way valves seems clinically beneficial with a remarkably good safety profile for patients with chronic hypercapnic respiratory failure.
Sections du résumé
BACKGROUND
Robust clinical evidence on the efficacy and safety of endoscopic lung volume reduction (ELVR) with one-way valves in patients with severe lung emphysema with chronic hypercapnic respiratory failure is lacking.
OBJECTIVE
The aim of this study was to compare patient characteristics, clinical outcome measures, and incidences of adverse events between patients with severe COPD undergoing ELVR with one-way valves and with either a partial pressure of carbon dioxide (pCO2) of ≤45 mm Hg or with pCO2 >45 mm Hg.
METHODS
This was a multicentre prospective study of patients with severe lung disease who were evaluated based on lung function, exercise capacity (6-min walk test [6-MWT]), and quality-of-life tests.
RESULTS
Patients with pCO2 ≤45 mm Hg (n = 157) and pCO2 >45 mm Hg (n = 40) showed similar baseline characteristics. Patients with pCO2 ≤45 mm Hg demonstrated a significant increase in forced expiratory volume in 1 s (p < 0.001), a significant decrease in residual volume (RV) (p < 0.001), and significant improvements in the quality of life and 6-MWT at the 3-month follow-up. Patients with pCO2 >45 mm Hg had significant improvements in RV only (p < 0.05). There was a significant decrease in pCO2 between baseline and follow-up in hypercapnic patients, relative to the decrease in patients with pCO2 ≤45 mm Hg (p = 0.008). Patients who were more hypercapnic at baseline showed a greater reduction in pCO2 after valve placement (r = -0.38, p < 0.001). Pneumothorax was the most common adverse event in both groups.
CONCLUSIONS
ELVR with one-way valves seems clinically beneficial with a remarkably good safety profile for patients with chronic hypercapnic respiratory failure.
Identifiants
pubmed: 35785772
pii: 000524996
doi: 10.1159/000524996
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
823-832Informations de copyright
© 2022 S. Karger AG, Basel.